Wire Break Location Test
The following lists identify the common locations where wire breaks occur.
Please inspect these areas for signs of damage.
Wire breaks in the twisted pair are commonly found:
1. At the wire exit point of the house
2. Where the twisted pair of wire enters the ground from the house,
usually caused by string trimmers
3. Where the wires cross sidewalks or driveways due to edging and
string trimmers
4. Around landscaping and flower beds due to digging, or working up
the soil
Wire breaks in the boundary wire are commonly found:
1. In aerated lawns
2. Where the wires cross sidewalks or driveways due to edging and
string trimmers
3. Around landscaping and flower beds due to digging, or working up
the soil
4. At wire splices where gel-filled capsules have not been installed
5. At wire splices without reinforcement knots (15A)
If you still cannot find the break in the boundary wire, there are
2 options for locating it:
Option 1: It is recommended to contact the Customer Care Center to
purchase a wire break locator (15B). The Wire Break Locator detects full
breaks, not partial breaks.
Option 2: Follow the procedure below:
1. Unplug the fence transmitter.
2. Connect both ends of your twisted boundary wire to one loop
terminal on the surge protector.
3. Measure and cut a test wire which is half the length of your total
boundary wire footage.
4. Connect one end of test wire to the other loop terminal on the
surge protector.
5. Locate the halfway point of your boundary and cut the boundary wire.
6. Splice the other end of the test wire to either side of your boundary
wire where you cut it in half.
7. Plug in the fence transmitter, set the mode to mode (B), and check the
loop indicator light. If the loop indicator light is on, you can assume that
the break is in the other half of the boundary wire.
8. If the loop indicator light did not come on, you may assume there is a
break in this portion of the boundary wire. However, there is a small
chance of having more than one break in your system. Be sure to check
both halves of your entire loop.
9. Replace the damaged boundary wire with new boundary wire.
10. Reconnect the boundary wire to the surge protector.
11. Check the loop indicator light. If the loop indicator light is on, test the
system with the receiver collar.
15 A
15 B
Receiver Collar Status Indicators
The receiver collar light and with the alarm tones are used to determine the operational mode, the battery status and the correction level. Refer
to the receiver collar status table below to understand the status lights and tones for the receiver collar. During normal operation, the receiver
collar light will flash every 4 seconds to indicate the battery status as shown in the table below. If your receiver collar has not been moved for
at least 20 seconds, the battery status light will function, but the receiver collar will enter sleep mode to conserve battery life. To wake up the
receiver collar simply pick it up and flip it over or shake it.
Receiver Collar Status Table
Light Status Alarm Tone Condition
While Plugged into the Receiver Charger
Solid red No tone Charge in progress
Solid green No tone Charge complete
No light No Tone Charge failure—contact Customer Care Center
ReadyTest® Startup
(After removing the receiver collar from the charger or after first turning it on)
Off for 1 second No tone Unit is starting the ReadyTest® startup feature
Continuous red, green, or red+green together
(5 seconds) No tone Battery charge status
Flashing red from 1 to 6 times No tone Receiver collar is reporting the
static correction level from 1 to 6
Continuous red 20 seconds ReadyTest® failure;
Unit is not operational—contact Customer Care Center
PerfectFit Test
Flashing red+green together
(every 1 second) No tone Unit is in PerfectFit mode for 90 seconds
after the ReadyTest® startup is completed
Flashing green
(every 1 second)
5 consecutive double tones
for a confirmed fit
PerfectFit mode indicates that the collar is making
true contact with the pet’s skin
Static Correction Level
Flashing red from 1 to 6 times No tone Receiver collar is reporting the
static correction level from 1 to 6
Receiver Activation Status
Fast pulsating green Warning tone Warning tone
Fast pulsating red Duration of the correction Static correction is being delivered
(up to 10 seconds)
Continuous green
(10 seconds) No tone Over Correction Protection feature;
Collar is locked for 10 seconds
Slow blinking green
(every 4 seconds) No tone Collar battery charge 100%–60%
Slow blinking red+green together
(every 4 seconds) No tone Collar battery charge 60%20%
Slow blinking red
(every 4 seconds) No tone Collar battery charge 20% or less;
Charge immediately
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Petsafe PIG00-11115 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info