507117
1
Zoom out
Zoom in
Vorherige Seite
1/54
Nächste Seite
42133 5415 341
www.philips.com/AVENT
Philips AVENT, a business of Philips Electronics UK Ltd.
Philips Centre, Guildford Business Park, Guildford, Surrey, GU2 8XH
Trademarks owned by the Philips Group.
© Koninklijke Philips Electronics N.V. All Rights Reserved.
k
l
n
o
j
m
p
q
A
1
A1 A2
A3
B
C
2
4
1
1
3
2
i
Single electronic breast pump
Tire-lait électronique individuel
Enkele Elektronische Borstkolf
Tiralatte elettronico singolo
GB
FR
NL
IT
For our complete catalogue of mother and
babycare products
call free on 0800 331 6015
GB ONLY (9am4.30pm Mon-Fri)
call free on 1800 744 5477
IRL ONLY (9am4.30pm Mon-Fri)
1 300 364 474
(Australia National)
Pour obtenir notre catalogue de produits de petite puériculture:
0805 025 510 (Appel gratuit sauf surcoût éventuel
selon opérateur)
De Suisse, composez le : 056 266 56 56
De Belgique / Luxembourg,
composez le : 0800 80 190 / 0800 26 550
Bel voor meer informatie of een product catalogus
de Philips AVENT consumentenlijn:
Nederland: 0800-023 0076 ( 0,25 p/m)
België/Luxemburg: 0800 80 190 / 0800 26 550
Per ricevere il nostro catalogo completo di prodotti per mamma
e bimbo, chiama il:
800 088774 (Numero gratuito – Il vostro operatore
telefonico potrebbe addebitarvi i costi della chiamata)
(dal Lunedì al Venerdì dalle 10.00 alle 17.30)
Svizzera: Vivosan, Tel. 056 266 56 56
FR
IT
NL
GB
AU
IRL
d
e
f
g
h
a
b
c
e
Breast pump – BPA-free
Tire-lait sans bisphenol A (0% BPA)
Handkolf – bevat geen BPA
Tiralatte – no BPA
Pump parts (diagram A1)
Breast pump parts
Dome cap
Extra soft AVENT Teat,
Newborn flow (0m+)
Screw ring
Sealing base
Sealing disc
Control handle* (diagram B)
Power socket
Control button
Control handle
Light
Battery pack* (diagram C)
Power cable
Bottle parts (diagram A2)
Only the following batteries are compatible
with the single electronic breast pvump
Battery pack: Duracell Ultra M3, Duracell Plus,
Energizer Ultra Plus, Duracell Accu (NiMH),
Ansmann (NiMH). For Duracell Acc (NiMH) &
Ansmann (NiMH) use/charge in accordance
with manufacturers guidelines. Dispose of
batteries as per manufacturer’s instructions.
Manual parts (diagram A3)
Handle
Pump cover
*NEVER STERILISE OR IMMERSE IN WATER
Control handle
*
Silicone diaphragm and stem
White valve
Pump body
Milk container (125ml/4oz)
Adaptor ring
Stand (same as )
Let-down Massage Cushion
Funnel cover (same as )
Battery pack
*
Mains power lead*
8
How to use your pump
(see diagram E)
Wash your hands thoroughly and make sure your breasts are clean. Relax in a
comfortable chair, leaning slightly forward (use cushions to support your back).
Make sure you have a glass of water nearby as expressing can be thirsty work.
A photograph of your baby will help too.
To begin pumping
1. Switch on at the wall socket if using mains power. To turn the pump on, press
and hold the control button for 2 seconds. The light on the top of the control
handle will flash ORANGE and then turn to a solid GREEN to indicate that the
pump is ready to use. If at any time the light is flashing red, stop and consult
the ‘Troubleshooting guide’.
2. Bring the assembled pump to your breast. Position the cushion firmly onto
your breast so as to create a perfect seal (ensure no strand of hair or piece
of clothing is trapped). Using the control handle you can find your exact
comfort level. As you press down on the handle, you will feel greater suction
against your breast. You don’t need to squeeze the handle fully, only as far
as feels comfortable for you.
3. Once comfortable, begin by gently squeezing the handle 5 or 6 times quite
quickly, simulating the rapid suckling you usually feel when your baby is first
put to the breast. Your milk will soon begin to flow and you can establish
a slower, comfortable pumping pattern. Many mothers find that holding
down the handle for 2 to 3 seconds at a time imitates the feeling of their
baby breastfeeding.
4. When you have established a comfortable pumping rhythm with at least
2 squeezes, simply press the control button on the handle, and the electronic
breast pump will automatically continue in the same way. The light on the
control handle will turn from solid GREEN to a flashing GREEN. Your pattern
will now be stored in the pump’s memory – even after the pump has been
switched off!
12
Hints to help you succeed
Using a breast pump takes practice. You may need to make several attempts
before you succeed, but because the single electronic breast pump is so simple
and comfortable to use, you will soon get used to expressing milk.
1. Choose a quiet time when you’re not rushed and unlikely to be disturbed.
2. Having your baby or a photograph of your baby nearby can help
encourage your milk to flow.
3. Warmth and relaxation can help so you might like to try expressing after
a warm bath or shower.
4. Placing a warm cloth on your breasts for a few minutes before you start
pumping can also encourage your milk flow and soothe painful breasts.
5. Try expressing from one breast while your baby is feeding from the other,
or continue expressing just after a feed.
6. Repositioning the pump on your breast from time to time can help
stimulate your milk ducts.
7. To relieve engorgement, we recommend gentle, slow pumping to relieve
the pressure.
Practice with your pump to find the best pumping techniques for you. Don’t
worry if your milk doesn’t flow immediately, relax and continue pumping.
Do not continue pumping for more than 5 minutes at a time if NO result
is achieved. Try expressing at another time during the day.
15
Using your electronic pump
as a manual breast pump
Your electronic breast pump can also be used as a manual pump. In this case,
you simply need to replace the control handle with the manual handle (p) and
pump cover (q) provided.
Assembling your manual breast pump (see diagram F)
Ensure you have disassembled, washed and sterilised all the parts.
Follow steps 1-5 as before (see diagram D), then proceed to step 6 and 7
(see diagram F):
6. Position the forked end of the handle (p) under the diaphragm stem (b)
and push down gently on the handle until you hear it ‘click’ into place.
7. Click the pump cover (q) onto the pump body (d).
How to use your manual breast pump (see diagram G)
1. Bring the assembled pump to your breast. Position the Let-down Massage
Cushion firmly onto your breast so as to create a perfect seal (ensure no
strand of hair or piece of clothing is trapped).
2. Once comfortable, gently squeeze the handle 5 or 6 times fairly quickly to
initiate let-down. When you see your milk beginning to flow, establish a
rhythm of pumping to meet your own comfort level.
16
Key to Control Handle Symbols
Technical Specifications
• Mains Input Voltage 100 – 240 VAC
• Mains Input Frequency 50 – 60 Hz
• Supply voltage fluctuations not exceeding +/- 10% of the nominal voltage
• Ambient Temperature range: +10˚C to +40˚C
• Atmospheric Pressure: 700 to 1060hPa
• Equipment rated for continuous operation
• Maximum speed at maximum vacuum is 60 cycles per minute
Guarantee
Philips AVENT guarantees that should the single electronic breast pump become
faulty during 24 months from the date of purchase, it will be replaced free of
charge during this time. Please return it to the retailer where it was purchased.
Please keep your receipt as proof of purchase, together with a note of when
and where purchased. For the Guarantee to be valid, please note:
The single electronic breast pump must be used according to the instructions
in this booklet and connected to a suitable electricity supply or the battery
pack provided.
The claim must not be a result of accident, misuse, dirt, neglect or fair wear
and tear.
This Guarantee does not affect your statutory rights.
If the retailer is unable to help, please contact Philips AVENT Customer Services
(see back cover for contact details).
TYPE B APPLIED PART
FOLLOW OPERATING
INSTRUCTIONS
ONLY USE INDOORS
CLASS II EQUIPMENT
GENERAL WARNING
EUROPEAN STANDARD
DISPOSE OF THROUGH
SEPARATE COLLECTION
ROUTE FOR WASTE
ELECTRICAL EQUIPMENT
17
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Philips-Avent SCF312 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info