Park & Stop
If you wish to interrupt vacuum cleaning, you can
place the tube clip into the rest (fig. 16).
You can slide the clip along the tube to change
the height.
In one movement the tube is parked in a
convenient position (fig. 17) and the motor is
switched off.
When you lift the tube from the rest the motor will
start again automatically.
Storage
- Switch the vacuum cleaner off (fig. 18).
- Remove the mains plug from the wall socket.
- Rewind the mains cord by pressing the
cordwinder pedal (i) (fig. 19).
- Hitch the lower tube onto the vacuum cleaner
(fig. 20-21). You can slide the clip along the
tube to change the height.
Replacing the dustbag
Only use this vacuum cleaner with the original
Philips dustbags types Oslo
+
or Oslo
+
Hygiene (closeable). Damage due to using
other dustbags is not covered by guarantee.
The "dustbag full indicator" will indicate when
the dustbag is full (fig. 22).
- Switch the vacuum cleaner off (fig. 18).
- Remove the hose (fig. 2).
- Open the cover (fig. 23).
- Remove the cassette with the full dustbag
(fig. 24).
- Remove the full dustbag from the cassette by
pulling the cardboard tag (fig. 25).
This automatically closes the dustbag (type
Oslo
+
Hygiene).
- Discard the full dustbag.
- Slide the cardboard front plate of the new
dustbag into the two slots of the cassette as far
as possible (fig. 26-27).
- Position the cassette and the new dustbag in
the vacuum cleaner (fig. 28).
- Bend the rear part of the dustbag downwards.
- Close the cover ("Click!") (fig. 29).
Note: If no dustbag has been placed into the
cassette, the cover cannot be closed.
Replacing the Active Carbon filter
Replace this filter once a year or when you notice
that smell absorbtion becomes less effective.
After having removed the full dustbag, you can
see the removable holder with the old Active
Carbon filter. You can take the holder to the
dustbin and shake the filter out there. Hygienic:
you need not touch the filter (fig. 31).
Position the new filter in the holder (fig. 30-31).
Press the holder with the new filter firmly into
place to ensure that it fits in correctly at the
bottom.
Replacing the S-Class filter
To guarantee optimum air filtering, the S-Class
filter needs replacement at least once a year.
- Open the filter holder (fig. 33).
- Remove the old filter (fig. 34).
- Positon the S-Class filter as indicated (fig. 35).
Ensure that the protruding notches fit well in
the apertures.
- Push the S-Class filter well into place (fig. 36).
- Position the filter holder in the vacuum cleaner
and close the filter holder (“Click!”) (fig. 37).
Replacing the mains cord
If the mains cord of this appliance is damaged, it
must only be replaced by Philips or their service
representative, as special tools and/or parts are
required.
Extra accessories
To enable you have even better profit from your
Philips Vision Plus vacuum cleaner, some extra
accessories are available from your dealer:
Turbo nozzle HR 6988 (fig. 38)
This turbo nozzle has been especially designed
for enhanced cleaning of rugs and carpets.
The rotating brush effortlessly picks up small
threads, hairs, fluff and more difficult to vacuum
particles.
Good in-depth cleaning is guaranteed with the
turbo nozzle.
Hard floor nozzle HR 6943 (fig. 39)
This nozzle is especially advisable for large
surfaces of parquet, tiles, etc.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Philips hr 8901fl wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info