401858
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Teeth for a lifetime with Philips/Jordan
Clean and healthy teeth give the security and confidence of good
appearance.
Furthermore, keeping one's teeth for a lifetime is the ultimate goal of
dental care. Your own daily dental hygiene as well as the efforts of your
dentist and other professionals are aimed at this. Philips/Jordan strongly
supports this objective.
What is dental plaque?
To safeguard healthy teeth and gums, proper and frequent removal of
plaque in all areas of the mouth is required.
Dental plaque is the main cause for dental diseases.
It is a soft and sticky fllm which continually develops on teeth, especially in
hard to reach areas as along the teeth line and in between teeth.
It has almost the same colour as teeth and is therefore hardly visible.
As long as plaque is still soft, it can be easily removed.
What are the effects of plaque?
The bacteria in the plaque produce an acid which can
dissolve the enamel of the teeth and the dentine beneath
it. This will cause dental decay (caries) (fig. 1)
The bacteria also form substances which may cause
inflammation of the gums (gingivitis) or decay of the
supporting tissue (periodontis).
Inflamed gums are generally red and swollen and often
bleed when the teeth are brushed (fig. 2).
Thorough and regular removal of plaque in all areas of the
mouth will prevent gingivitis from starting and will help stop
the spread of periodontitis.
Philips/Jordan 2-Action plaque remover
2-Action Brush
The power of this new developed plaque removal system is in the double
performance of the oscillating brush.
Fast oscillating movements combined with the additional active tip
movements in the space between the teeth, result in a
thorough and highly effective cleaning of every area of the
teeth (fig. 3).
Controlled Pressure
Proper cleaning technique requires excellent handling of a
brush as it is a balancing act between applied pressure
and movements.
Too much pressure may damage both teeth and gums, causes
unneccessary wear of the brush and also reduces the effectiveness of the
brushing operation.
The Controlled Pressure system helps you to control applying the correct
pressure when brushing your teeth.
When the pressure level is exeeded, the brush actively warns you by a
sudden change in the position of its
neck.
This may occur often when first time
used.
Clinical tests show that the Controlled
Pressure will assist you in developing
effective electrical brushing
techniques for cleaning at the right
pressure, within a few days (fig. 4).
General Description (fig. 5)
A 2-Action brush head
B Oscillating brush
C Active tip
D Coloured identification ring (click-on)
E Drive shaft
F ”Controlled Pressure” bending head
G Brushing time indicator (Type HP 735 only)
H Speed selector (button)
I On/off switch (button)
J Charge control (Types HP 710 and HP 735 only)
K Screws and rawlplugs for wall mounting
L Charge unit with mains cord
M Brushes storage compartment - for two 2-Action brush heads
(Type HP 735 only)
N Inner container for M
O Brush peg - for one 2-Action brush head
(Types HP 510, HP 610 and HP 710 only)
P Cord storage compartment
Bathroom use
Using the mounting plate, mount the charge unit to a wall where it
cannot accidentally fall into water.
As the toothbrush itself is waterproof you may choose to use it while
having a shower or bath.
Cord storage (fig. 6)
Wall mounting (fig. 7-8a)
How to charge (fig. 9-11)
Before first use charge for at least 16 hours.
In normal use, the toothbrush is recharged after each use by just placing
it back into the connected charge unit.
As long as the battery is being (re)charged the green pilot light will be
on.
To guarantee a long life, it is important to let the toothbrush run until it is
completely empty and then recharge it for 12 hours at least once every six
months.
How to use (fig. 12-16)
Let the toothbrush do the work for you: just guide the bristle carefully
along the teeth. The active tip will find its own way and enter into the
spaces in between the teeth. Ensure that the brush touches the entire
tooth surface as well as a small section of the gums.
If the head clicks backwards during brushing, this means that you have
applied too much pressure (fig. 17).
Also refer to the provided Tooth Brushing Instructions card.
- Position (push and turn) the 2-Action brush head on to the appliance
(fig. 12).
- Press button (I) to switch on (fig. 14).
The toothbrush will start at high speed.
- To change speed press button (H) (fig. 15). (Types HP 710 and HP 735
only.)
Minimum brushing time: 2 minutes (fig. 18)
Two minutes is regarded to be the minimum time required for effective
plaque removal and gum massage.
For even better results you may decide to brush longer.
Remember that fluoride in toothpaste also needs some time to act.
(Type HP 735 only:) To help you brush systematically (fig. 18) the
brushing time indicator (G) will come on for 10 seconds at intervals of
30 seconds.
After brushing your teeth (fig. 19-21)
Cleaning
- Switch the toothbrush on and rinse it clean in lukewarm (max. 60 °C)
water.
- The charge unit can be cleaned with a damp cloth. Unplug before
cleaning!
- (Type HP 735 only:) The inner container is removable and can be
washed (also dishwasher safe).
Replacement 2-Action brush heads
For replacement, new 2-Action brush heads are available from your dealer
under type n°. HP 790.
Protecting the environment
To remove the built-in rechargeable battery when eventually discarding
your appliance: see fig. 22-24.
Please note: You can also take the appliance to a Philips Service
Centre. The staff will be happy to help you.
Before removing the battery should be completely empty of charge. Let
the appliance run until the motor stops.
Please note: Only unscrew the bottom for battery removal.
The toothbrush may not be watertight anymore after the bottom has
been unscrewed. For that reason the guarantee is void after opening the
toothbrush.
An undamaged sticker at the bottom side indicates that the appliance
has not been opened.
For U.K. only:
Mains plug
The mains plug of the charging unit meets the latest European standards.
The plug is completely safe, although the standard UK shaver socket
holes may be slightly too wide for the pins of the plug. Please make sure a
proper connection is made.
If the plug must be inserted into a 3-pin socket, use a suitable shaver
adapter.
Des dents pour la vie avec Philips/Jordan
Une dentition propre et saine vous permet d'être sûr de vous-même et
d'avoir confiance dans votre physique.
Mais l'hygiène dentaire quotidienne a aussi pour objectif de vous aider à
conserver vos propres dents jusqu'à la fin de vos jours. Les efforts de
votre dentiste et autres professionnels ont le même but.
Philips/Jordan soutient vigoureusement cet objectif.
Pour conserver des dents et des gencives saines, il faut éliminer
fréquemment et correctement la plaque dentaire.
Qu'est ce que la plaque dentaire?
La plaque dentaire est la cause principale des maladies dentaires. C'est
un film souple et collant qui se développe en permanence sur les dents,
en particulier dans les régions difficiles à atteindre telles que la base de la
dent ou les espaces inter-dentaires.
Elle est presque de la même couleur que les dents, et donc difficilement
visible.
Tant que la plaque reste souple, elle s'enlève facilement.
Quels sont les effets de la plaque?
Les bactéries de la plaque génèrent un acide qui peut
dissoudre l'émail des dents et la dentine qui se trouve
derrière. Cela provoque la détérioration des dents (caries)
(fig. 1).
Les bactéries forment aussi des substances qui peuvent
causer une inflammation des gencives (gingivite) ou
détruire le tissu de soutien (périodontite).
Les gencives enflammées sont généralement rouges et
gonflées et saignent souvent lorsqu'on se brosse les dents
(fig. 2).
Une élimination minutieuse et régulière de la plaque dans
toutes les zones de la cavité buccale permet d'éviter la
gingivite avant même son apparition et aide à stopper la
périodontite.
A
M
N
O
O
D
E
G
H
F
I
K
J
L
B
C
P
HP 510/HP 610
HP 735
HP 710
5
6
CLICK
9
10
1
2
12
CLICK
14
13
CLICK
15
11
21 mm
7
2
8a
8
1
20
21
23
24
CLICKCLICK
17
2
22
1
18
2
min.
30
sec.
30
sec.
30
sec.
30
sec.
19
16
English
Français
1
2
1
2
3
CLICKCLICK
4
Important
The appliance must always be mounted to the wall.
First charging: at least 16 hours.
The mains cord of this appliance cannot be replaced.
If the cord is damaged, the appliance should be discarded.
For optimum brushing efficiency and for hygiene: replace the
2-Action brush heads as soon as the hairs begin to stand out
or at least every three months.
It is advisable to use your electrical toothbrush twice a day for
at least two minutes.
The built-in rechargeable battery contains substances which
may pollute the environment.
When eventually discarding your appliance please remove the
built-in rechargeable battery (fig. 22-24) and dispose of it at an
officially assigned refuse site.
Please refer to section Protecting the environment.
La brosse 2-Action anti-plaque Philips/Jordan
Brosse 2-Action
La puissance de ce nouveau système anti-plaque réside
dans la double action de la brosse oscillante.
Les mouvements oscillatoires rapides combinés avec les
mouvements de la pointe active dans les espaces
interdentaux permettent de nettoyer soigneusement et très
efficacement toutes les zones des dents (fig. 3).
Contrôle de la pression
Une bonne technique de nettoyage nécessite une excellente
manipulation de la brosse car tout est une question d'équilibre entre la
force appliquée et les mouvements. Une pression trop importante peut
endommager les dents et les gencives, user inutilement la brossette et
donc nuire à l'efficacité du brossage.
Le système de contrôle de la pression vous aide à contrôler la pression
que vous appliquez lorsque vous vous brossez les dents.
Si la pression est trop forte, la brosse vous prévient de manière active en
modifiant brusquement la position de
son manche.
Cela peut se produire souvent lors de
la première utilisation.
Les tests cliniques montrent que le
contrôle de pression vous aide à
développer en quelques jours une
technique de brossage électrique
efficace (fig. 4).
Description générale (fig. 5)
A Tête de brossage 2-Action
B Brosse oscillante
C Pointe active
D Bague d'identification colorée (encliquable)
E Tige d'entraînement
F Tête flexible à contrôle de pression
G Indicateur de temps de brossage (type HP 735 uniquement)
H Sélecteur de vitesse (bouton)
I Interrupteur marche/arrêt (bouton)
J Contrôle de charge (types HP 710 et HP 735 uniquement)
K Vis et chevilles pour montage mural
L Unité de chargement avec cordon d'alimentation secteur
M Compartiment de rangement des brosses pour deux têtes de
brossage 2-Aaction (type HP 735 uniquement)
N Boîtier intérieur pour M
O Cheville à brosse pour une tête de brossage 2-Action
(types HP 510, HP 610 et HP 710 uniquement)
P Cordon de rangement du cordon
Utilisation dans une salle de bain
Montez la platine de l'unité de chargement sur un mur où celle-ci ne
risque pas de tomber dans l'eau par accident.
La brosse à dents elle-même étant étanche, vous pouvez l'utiliser sous
la douche ou dans votre bain.
Rangement du cordon (fig. 6)
Montage mural (fig. 7-8a)
Procédure de mise en charge (fig. 9-11)
Avant la première utilisation, l'appareil doit être mis en charge
pendant au moins 16 heures.
En mode d'utilisation normale, la brosse à dents se recharge après
chaque utilisation lorsque vous la replacez dans l'unité de chargement
connectée.
Tant que la pile est en cours de (re)chargement, le témoin lumineux vert
est allumé.
Pour garantir une longévité plus importante de votre appareil il est
souhaitable (tous les 6 mois) de laisser se décharger complètement les
accumulateurs puis de les recharger pendant au moins 12 heures.
Procédure d'utilisation (fig. 12-16)
Laissez la brosse à dent travailler à votre place : il vous suffit de la
guider soigneusement le long des dents. La pointe active trouve son
propre chemin et pénètre dans les espaces interdentaux. La brosse doit
toucher toute la surface des dents ainsi qu'une faible partie des
gencives.
Si la tête revient en arrière en cours de brossage, cela signifie que vous
avez appuyé trop fort (fig. 17).
Consultez aussi la notice d'instructions de brossage.
- Positionnez (enfoncez et tournez) la tête de brosse double action sur
l'appareil (fig. 12).
- Appuyez sur le bouton (I) pour mettre en marche (fig. 14).
La brosse à dents démarre à grande vitesse.
- Pour régler la vitesse, appuyez sur le bouton (H) (fig. 15)
(types HP 710 et HP 735 uniquement).
Temps minimum de brossage: 2 minutes (fig. 18)
Une durée de deux minutes est considéré comme le temps minimum
nécessaire pour éliminer efficacement la plaque et masser les gencives.
Pour obtenir des résultats encore meilleurs, vous pouvez décider de vous
brosser les dents plus longtemps.
N'oubliez pas que le fluorure contenu dans la pâte dentifrice met un
certain temps pour agir.
(Type HP 735 uniquement) Pour vous aider à vous brosser les dents de
manière plus systématique (fig. 18), l'indicateur de temps de brossage (G)
est activé pendant 10 secondes toutes les 30 secondes.
Après le brossage (fig. 19-21)
Nettoyage
- Mettez votre brosse en marche et rincez-la à l'eau tiède (60°C
maximum).
- L'unité de chargement peut être nettoyée avec un chiffon humide
(débranchez-la avant de la nettoyer).
- (Type HP 735 uniquement) Le boîtier intérieur est amovible; vous
pouvez le laver (il peut passer au lave-vaisselle).
Remplacement des têtes de brosse 2-Action
Vous pouvez vous procure des têtes de brosse 2-Action de rechange
chez votre fournisseur, sous la référence HP 790.
Protection de l'environnement
Pour démonter la pile rechargeable intégrée si vous jetez votre appareil,
voir fig. 22-24.
Note : vous pouvez également envoyer votre appareil à un Centre
Service Agréé. Le personnel se fera un plaisir de vous aider.
Avant d'être démontée, la pile doit être complètement vide. Laissez
l'appareil fonctionner jusqu'à ce que le moteur s'arrête.
Note : Pour démonter la pile, il suffit de dévisser le fond de l'appareil.
Lorsque le fond est dévissé, la brosse à dents n'est plus étanche. C'est
pourquoi la garantie est annulée lorsque la brosse a été ouverte.
Une étiquette est collée sous le fond de l'appareil pour témoigner du fait
qu'il n'a pas été ouvert.
3
CLICKCLICK
4
Important
L'appareil doit toujours être fixé au mur à l'aide des vis et du
support fournis
Première mise en charge : au moins 16 heures.
Le cordon d'alimentation secteur de cet appareil ne se remplace
pas. Si le cordon est endommagé, il faut jeter l'appareil.
Pour une efficacité de brossage et une hygiène optimales, les
têtes de brossage 2-Action doivent être remplacées dès que les
poils commencent à s'écarter ou au moins tous les trois mois.
Nous vous recommandons d'utiliser votre brosse à dents deux
fois par jour pendant au moins deux minutes.
La pile rechargeable intégrée contient des substances
susceptibles de polluer l'environnement.
Si vous jetez votre appareil, veuillez enlever la pile
rechargeable intégrée (fig. 22-24) et la déposer dans un
container prévu à cet effet. Reportez-vous au paragraphe
"Protection de l'environnement".
4203 000 42725
;
HP 510/610/710/735
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Philips jordan hp 610 xh extra handle wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info