The MCACC PRO menu
11
3 If you selected ‘Reverb Measurement’, select EQ ON or EQ OFF, and then START.
The following options determine how the reverb characteristics of your listening area are displayed in
Reverb View:
! EQ OFF – You will see the reverb characteristics of your listening area without the equalization performed by
this receiver (before calibration).
! EQ ON – You will see the reverb characteristics of your listening area with the equalization performed by this
receiver (after calibration). Note that the EQ response may not appear entirely flat due to adjustments neces-
sary for your listening area.
The calibration corresponding to the currently selected MCACC preset will be used when EQ ON is
selected. To use another MCACC preset, press MCACC to select the MCACC memory you want to store.
After auto calibration with EQ Type : SYMMETRY (Auto MCACC, etc.), the graph for the inferred reverb
characteristics can be displayed by selecting Reverb View. To display the actually measured reverb char-
acteristics after EQ calibration, measure with EQ ON.
When the reverb measurement is finished, you can select Reverb View to see the results on-screen. See
Professional Calibration EQ graphical output on page 117 for troubleshooting information.
4 If you selected ‘Reverb View’, you can check the reverb characteristics for each channel.
Press RETURN when you’re done.
The reverb characteristics are displayed when the Reverb Measurement measurements are conducted.
Use k/l to select the channel, frequency and calibration setting you want to check. Use i/j to go back and
forth between the three. The reverb characteristics graph before and after EQ calibration can be displayed by
selecting Calibration : Before / After. Note that the markers on the vertical axis indicate decibels in 2 dB steps.
5 If ‘Advanced EQ Setup’ is selected, select the MCACC memory to be stored, then enter the
desired time setting for calibration, and then select START.
! To specify the place where the MCACC memory is to be stored, press MCACC to select the MCACC memory
you want to store.
Based on the reverb measurement above, you can choose the time period that will be used for the final frequency
adjustment and calibration. Even though you can make this setting without reverb measurement, it is best to use
the measurement results as a reference for your time setting. For an optimal system calibration based on the
direct sound coming from the speakers, we recommend using the 30-50ms setting.
Use k/l to select the setting. Use i/j to switch between them.
Select the setting from the following time periods (in milliseconds): 0-20ms, 10-30ms, 20-40ms, 30-50ms,
40-60ms, 50-70ms and 60-80ms. This setting will be applied to all channels during calibration.
When you’re finished, select START. It will take about 2 to 4 minutes for the calibration to finish.
After the Acoustic Calibration Equalization is set, you are given the option to check the settings on-screen.
Precision Distance
SC-LX88 only
Before using this function, perform the Full Auto MCACC Setup procedure (see page 49 ). Performing the Full
Auto MCACC procedure corrects the distance to a precision of 1 cm, but the Precision Distance function lets
you adjust the distance to the speakers (their position) with a precision of under 1 cm. Here, rather than correct
the numerical value of the distance, actually move the physical positions of the speakers to fine-adjust (the sub-
woofer cannot be adjusted). The input from the microphone is indicated on the screen. Fine-adjust the positions
of the speakers so that the gauge reading is maximum. The detailed distance adjustments that were previously
performed by skilled installers by ear can easily be performed watching the gauge on the monitor. Place the
microphone in the same position as when the microphone was connected and the Full Auto MCACC operation
was performed.
1 Select ‘Precision Distance’ from the Manual MCACC setup menu.
2 Fine-adjust the positions of the speakers in sequence, starting from the front right channel.
Test pulses are output from the speaker for the selected channel and from one other speaker. Move the position
of the selected speaker 1 cm towards or away from the microphone. Watch the screen when doing so, and fine-
adjust the positions of the speakers so that the gauge reading is maximum. Also, the channel serving as the stan-
dard differs according to the channel being adjusted. Do not move the speaker serving as the standard channel.
The maximum gauge reading is 10.0. (If the reading stays under 10.0, adjust the speaker for the maximum value.)
! If the microphone is placed in a different position from when the Full Auto MCACC or Auto MCACC proce-
dure was performed, it may not be possible to adjust properly. In this case, we recommend performing the
procedure at Fine Speaker Distance on page 97 in the Manual MCACC measurements, then performing
the adjustment described here without moving the microphone.
! The adjustment here is for adjusting for an error of 1 cm or less (not adjustable with the Auto MCACC Setup).
0.0 may be displayed after distance correction with the Auto MCACC Setup, but even in this case this adjust-
ment allows you to optimize the correction. Note that if the Auto MCACC Setup is performed after completing
the fine-adjustment here, the correction precision will drop to about 1 cm.
! Like with the Auto MCACC Setup, perform this adjustment in as quiet an environment as possible. 0.0 will be
displayed if abrupt noise is input during the adjustment.
! The distance for all the channels can only be made uniform even if the R (front right) channel is adjusted in
the proper order.
! Be very careful not to tip the speakers over when moving them.
! The result of the adjustment performed here can be checked by listening to the test pulses output at the
Precision Distance (the test pulses will be more centrally positioned between the speakers than before the
adjustment was performed). Be careful not to change the distance values at this time.
3 When you’re finished, press RETURN.
You will return to the Manual MCACC setup menu.
 
99

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Pioneer SC-LX78-S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Pioneer SC-LX78-S

Pioneer SC-LX78-S Kurzanleitung - Deutsch - 76 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Deutsch - 151 seiten

Pioneer SC-LX78-S Kurzanleitung - Englisch, Holländisch - 76 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Holländisch - 146 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Dänisch - 424 seiten

Pioneer SC-LX78-S Kurzanleitung - Französisch - 76 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Französisch - 145 seiten

Pioneer SC-LX78-S Kurzanleitung - Italienisch - 76 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Italienisch - 144 seiten

Pioneer SC-LX78-S Kurzanleitung - Spanisch - 76 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Spanisch - 146 seiten

Pioneer SC-LX78-S Bedienungsanleitung - Schwedisch, Norwegisch, Finnisch - 424 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info