or minimum value, respectively.
Parameters associated with integer commands can be queried using the '?' character. For example, if input A 's
gain is set to 12, and you send 'F04GAINIA? ', the device will respond with a status message of 'F04GAINIA12
'.
6.3. Channel Commands
A command can be a channel command in addition to being one of the other types of commands (integer or
boolean). A channel command means that the command applies to a specific input or output channel. The
channel is specified by a single character (e.g., '1', '2', 'A', 'B', etc.) occurring before any other payload data.
An example of a boolean channel command is the '
AGC' (Automatic Gain Control) command. 'F04AGC30 '
disables the AEC on input channel 3 . After sending this command, the device will respond with a status message
of 'F04AGC30 '.
An example of an integer channel command is the '
GAINI' command, which adjusts the gain on the input
channels. 'F04GAINIA12 ' sets the input gain of channel A to 12 dB. After sending this command, the device will
respond with a status message of 'F04GAINIA12 '.
A wildcard character ('*') can be used as the channel specifier for many of the channel commands. If this is the
case, there are two options for specifying the values for the channels. The first method is to specify a single
value that will be applied to all the channels.
Take the
MUTEI command for example: 'F04MUTEI*1 ' mutes input channels 1-8 and A-D After sending this
command, the device will respond with a status message of 'F04MUTEI*111111111111 '. In this status
message, the device reports the status of all the channels. Since the MUTEI command applies to channels 1-8
and A-D the status of all 12 channels. The first (left most) value corresponds to channel 1 and the last (right
most) value corresponds to channel D .
This leads us to the second method of using a wildcard character: specifying the values for each of the channels.
For example, 'F04MUTEI*101010101010 ' mutes channels 1, 3, 5, 7, A, C and unmutes channels 2, 4, 6, 8, B,
D . In this case, the device will respond with a status message of 'F04MUTEI*101010101010 '.
As an interesting example, consider sending 'F04MUTEI*2 ' after the above example. The device will respond
with a status message of 'F04MUTEI*010101010101 '. Notice that all the states have been toggled.
Queries using the '?' character are straightforward. For example, 'F04MUTEI1? ' might return 'F04MUTEI11 ',
while 'F04MUTEI*? ' might return 'F04MUTEI*111111110000 '.
Using the wildcard character with integer channel commands is similar to using it with boolean commands, but
there are some differences. If we sent 'F04GAINI*10 ', the input gains on channels 1-8 and A-D will all be set
to 10 dB. The device will respond with a status message of 'F04GAINI*ÄÄÄÄÄÄÄÄÄÄÄÄ '. Those weird
characters are the main difference between using wildcards with integer channel commands versus boolean
channel commands. When reporting multiple integer values, the Vortex uses a binary format with one byte per
integer value. This allows for more compact commands and reduces RS-232 and bus traffic. To convert from an
integer value to a byte value, we add 132 to the integer value. In the above example, where the gain is set to 10
dB, we have: 10 + 132 = 142 = 0x8E (hex) = Ä (ASCII). The reason for adding 132 is to allow us to
conveniently represent negative numbers as well as avoid the use of special characters that are normally used in
RS-232 and EF Bus communications.
When using a wildcard character to specify separate values for each channel, you must also use the binary
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Polycom Vortex EF2280 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Polycom Vortex EF2280

Polycom Vortex EF2280 Bedienungsanleitung - Englisch - 62 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info