POWDP1570 EN
Copyright © 2018 VARO P a g e | 8 www.varo.com
▪ Solid green: charged.
▪ Solid green and red: battery or charger damaged.
Note: If the battery does not fit properly, disconnect it and confirm that the
battery pack is the correct model for this charger as shown on the
specification chart. Do not charge any other battery pack or any battery
pack that does not securely fit the charger.
1. Frequently monitor the charger and battery pack while connected.
2. Unplug the charger and disconnect it from the battery pack when finished.
3. Allow the battery pack to cool completely before using it.
4. Store the charger and battery pack indoors, out of reach of children.
NOTE: If battery is hot after continuous use in the tool, allow it to cool down
to room temperature before charging. This will extend the life of your
batteries.
NOTE: Remove battery pack from charger stand which use your thumb or
fingers, press the battery’s release button in and pull the battery pack off at
the same time.
9.2 Battery capacity indicator (Fig. 1a)
There are battery capacity indicators on the battery pack; you can check the capacity status of
the battery if you squeeze the button (12). Before using the machine, please press switch
trigger to check if the battery is full enough for properly working.
Those 3 LED might show the status of the capacity level of the battery:
3 LED’s are litt: Battery fully charged.
2 LED’s are litt: Battery 60% charged.
1 LED is litt: Battery almost discharged.
9.3 Inserting and removing the battery (Fig. 2)
WARNING: Before making any adjustments ensure the drill is switched off
with the direction of rotation selector in the centre position
▪ Remove the battery: press the battery release latch in and at the same time pull the
battery pack off.
▪ To insert the battery, push the battery pack onto the contacts of the tool.
9.4 Fitting and changing tools (Fig. 3)
The device is equipped with a SDS-plus attachment system.
▪ Clean tools and grease with a thin layer of machine grease before fitting.
▪ Pull back fastening sleeve and hold.
▪ Push and rotate the dust-free tool into the tool holder as far as it will go. The tool will lock
automatically.
▪ Check that it has locked by pulling the tool
9.5 Removing SDS-plus tool
Pull back fastening sleeve, hold and remove tool.
Accessories can be hot after use. Don’t touch the tip of accessory by hand!
Please always use protective gloves to remove accessories.