6.1 Assembly (Fig. 1)
First attach left, right and rear table extensions to the table saw (without the brackets)
Mount the base frame and attach it to the table saw
The base frame (13) consists of four table legs with cross braces that must be mounted.
Required tools:
2 combination spanners
▪ Attach the four table legs (19) to the corners of the saw table. Note that the legs on the
rear must be mounted so that the holes for the assembly of the tilt protection devices face
the rear of the machine.
▪ Mount the cross braces A on the front and rear between legs (13).
▪ Mount the cross braces A on the sides between legs (13).
Do this by attaching each cross brace on the inside to each table leg with two screws, washers
and locking nuts.
▪ Push the rubber feet (17) onto the supporting legs.
▪ Finally, fit the four brackets (21) with the table extension and the table legs.
The brackets (21) are fitted through the screw holes in the housing.
Note: Only place the device on a level, skid-proof surface. The device must
not wobble.
6.2 Attaching the tilt protection (Fig. 2)
▪ Bolt the tilt protection to the rear supporting legs using bolts (A), washers, spring washers
and nuts.
6.3 Fitting the parallel fence (Fig. 3)
Insert the parallel fence (12) into the rail of the measuring scale. Check the setting at the
window. Push the locking lever (10) downwards to lock the parallel fence (12) into place. In
order to obtain a perfectly parallel cut, you should check the gap between the fence and the
saw blade at two positions using a meter rule.
6.4 Mounting mitre angle stop (Fig. 4)
The mitre angle stop (11) consists of two parts - the stop plate (A) and the angle adjustment
(B) that must be assembled together.
▪ Insert the stop plate (A) into the gaps of the angle adjustment (B) with both adjusting
screws (C), push into the required position and tighten the adjusting screws.
Push the gliding bar (D) of the mitre angle stop into the required bar of the table surface.
Right-handed operators prefer to push the mitre angle stop into the left bar
of the table surface.
6.5 Mounting the saw blade guard (Fig. 5)
Risk of injury! The saw blade must be at least set to 30mm height.
▪ First, mount the crank (2).
▪ Put the blade in the highest position.
▪ Position the saw blade protection on the cleaving wedge (8) so that bolt (22) engages in
the hole. Push and at the same time tighten the bolt..
6.6 Mounting the extraction hose (Fig. 6)
▪ Place the vacuum hose (5) on the connecting piece of the saw blade guard (7).
▪ Put the vacuum hose (5) on the vacuum connecting piece (23) on the rear of the device