GENERATOR ENCLOSURES
Some installations require the Genset to be mounted inside an enclosure. Enclosures are
generally constructed of heavy gauge sheet metal, and completely insulated. Enclosures are
typically installed in RV’s with large unobstructed compartments. The major advantage to
installing a Genset in an enclosure is to achieve a significant reduction in the unit’s sound level.
In order to maintain the ambient temperature within the enclosure a forced cool air
system is generally employed. Two blower fans capable of producing a minimum of 465 CFM
each should be mounted at the generator end of the enclosure. Cooling air circulates around the
generator end and engine, forcing excess heat to exit through an air duct outlet to the outside air.
Since hot air will rise the air duct outlet opening should be located near the inside top surface of
the enclosure, the opening should be approximately 25 square inches.
Openings in the base of the enclosure and compartment floor are required for the engine
exhaust pipe, oil drain hose and engine breather hose. Other holes for fuel lines, electrical leads,
remote radiator hoses, etc. are usually located in the rear wall of the enclosure. Be sure to seal
around these items to prevent fumes or vapors from entering the vehicles compartment. Two
hinged doors at the front of the enclosure enable unobstructed access to the engine and control
box for routine maintenance. A removable service panel in the rear wall of the enclosure
facilitates servicing the back side of the Genset.
The clearance between the enclosure and the vehicles compartment walls is another
consideration. Except for the rear wall of the enclosure the clearances at the top, sides and front
can be minimal. A ½” gap per side is enough clearance for easy installation or removal. At the
rear of the enclosure the compartment depth must be large enough to accommodate the two
blower fans and system connections. A minimum of 10” between the enclosure and rear
compartment wall is required for this area. Also, remember a 400 sq. inch free air opening is
required to supply the forced air cooling system. See section on “Air Requirements” for details.
Dimensions and layouts are provided for your planned installation, be sure to follow all
requirements. Power Technology’s Customer Service Department is available to answer any
questions you may have concerning your Genset and installation.
IMPORTANT: When installing a RV generator set the installation must comply with the
current Safety Standards of ANSI / RVIA EGS-1-2003, ANSI A 119.2 / NFPA 501C and
applicable articles of ANSI / NFPA 70 of the National Electrical Code. Generator set
installations must also comply with state and local requirements.
IMPORTANT: An enclosure manufactured by any person (s) other then Power Technology
must follow the requirements set forth in this manual. All specifications must be adhered to;
failure to do so may affect your Power Technology Southeast, Inc. Limited Warranty.
7
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für PowerTech PTRV-17.5KT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info