5 Keys : SET - C/F - DOWN/CH - RF ALARM - SNZ/LIGHT
RCC reception from: DCF
Barometric pressure display
Weather forecast: Sunny, Partly sunny, Cloudy, Rainy and Stormy
Low Battery indicator for outdoor sensor and station
Time,date and week display
Temperature in °C/°F
Indoor temperature (0°C~50°C)
Outdoor temperature (-40°C~60°C)
Indoor humidity (20%-99%)
Outdoor humidity((20%-99%))
Outdoor/indoor temperature and humidity trend
Moon phase display
Alarm and Snooze
Summertime setting
LED back light
Functions
A. START OR RESET
Default time : 2013.01.01 00:00
Default temperature °C
Barometer unit : Hpa
Weather station : partly sunny
DST : ON
The LCD display lights up for 3 seconds when changing new battery or reset-
ting, then with a sound BI the display turns into normal state, after testing
temperature and barometer, and receiving RF for 3 minutes:Then enters in
to RCC reception mode.
B. TIME SETTINGS
In the time display mode Press “SET” for 2 seconds to enter time setting :
Press “SET” to navigate between settings :
Time zone - 12/24HR - Hour - Minute - Year - Month - Day - Barometer - Exit
Press “UP/RCC” once to go ahead one step; press and hold for 2 seconds, go
ahead 8 steps/seconds speed.
Press “DOWN/CH” once to go back one step, press and hold for 2 seconds, go
back 8 steps/seconds speed.
Info :
The pascal (symbol: Pa) is the SI derived unit of pressure, and is defined as one
newton per square meter.[1]
Common multiple units of the pascal are the hectopascal (1 hPa = 100 Pa) which is
equal to one millibar,
Inches of mercury, (inHg and "Hg) is a unit of measurement for pressure. It is still
used for barometric pressure in weather reports, refrigeration and aviation in the
United States.
It is defined as the pressure exerted by a circular column of mercury of 1 inch in
height at 32 °F (0 °C) at the standard acceleration of gravity : 1 inHg = 3386.389 Pa
at 0 °C.
C. ALARM SETTINGS
At standard mode : press ALARM” swift to enter alarm mode
The ALM” will display on the position of weekday .
At ALARM” mode : press ALARM” the alarm icon will appear or disappear (alarm
ON/OFF)
Hold ALARM” enter to alarm setting , the hours starts twinkling
Press ALARM to navigate between settings : hour - minute - exit
Press “UP/RCC” once to go ahead one step; press and hold for 2 seconds, go ahead
8 steps/seconds speed.
Press “DOWN/CH” once to go back one step, press and hold for 2 seconds, go back
8 steps/seconds speed.
After setting : press ALARM” to confirm or do not touch any key for 10s to exit
settings
D. ALARM AND SNOOZE
Default time : am 7:00
With a sound BIBI for 2 minutes ,when setting alarm time is coming
When alarm sounds , press SNZ/LIGHT” to active snooze :the clock will start
beeping again after 10 minutes.
No matter on alarm mode or snooze , press any key except SNZ/LIGHT to exit
and return to normal time mode.
E. INDOOR TEMPERATURE
Temperature range 0°C/32°F +50°C/122°F
Testing cycle : 30 seconds
Temperature resolution +/- 1°C
When the current temperature exceeds the maximum temperature ,it will
show maximum temperature
When the current temperature is lower than the minimum temperature, it
will show the minimum temperature .
When ALRM/RCC/RF the clock will stop checking temperature until ALARM/
RCC/RF stops
Temperature trend
Temperature rise of 1°C/2°F,arrow upward
Temperature drop 1°C/2°F,arrow down
Temperature changes in the scope of 1°C/2°F, arrow displays horizontal.
Temperature compared at the current date and the date before 3 hours,
the clock records data every 30 minutes
F. OUTDOOR TEMPERATURE
Temperature range : -40°C/-40°F +60°C/140°F
Temperature resolution +/- 1°F
When the current temperature exceeds the maximum temperature ,it will
show maximum temperature
When the current temperature is lower than the minimum temperature, it
will show the minimum temperature .
The clock will register RF signal for 3 minutes automatically when power by
battery, then enter RCC receiving
EN
ELTRA NV
Pachtgoedstraat 2
9140 Temse
www.profile.eu
Art. 201100008
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Profile 211000008 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info