MULTIMETER MEDIUM EN - 1
PIN-112
We thank you for the purchase of this Profile
product. Note: It is important that you read this
manual before using the product. Save this manual
for possible use later.
Operating controls and connections
(See figure)
1. LCD
2. Function switch
3. COM (negative) input connection
4. 10A (positive) input connection for 10A DC or
AC measurement
5. Positive input connection
6. HOLD push button
7. Background lighting
Symbols and messages
Continuity
BAT Battery nearly empty
Diode
V
~ AC voltage
V DC voltage
A Direct current
μ Micro (Ampere)
m Milli (Ampere)
k Kilo (Ampere)
Ohm
Danger live voltage
Consult the manual
Safety class II, Double insulated
Operation
Warning: Risk of electrocution. Circuits with high
voltages (both direct and alternating) are very
dangerous and must be very carefully measured.
1. ALWAYS switch the function switch to the OFF
position when the meter is not being used.
2. When "1" appears on the display during a
measurement the value exceeds the range you
have selected. Choose a higher range.
Opm.: With some low AC and DC ranges the
display may show a random, varying measured
value although the testing wires are not connected
to an appliance. This is normal and caused by the
high input sensitivity. The measured value will
stabilise and a correct measurement will be shown
on connection to a circuit.
Display background lighting
Briefly press the backlight key (7). The lighting will
be automatically switched off after 10 seconds.
Hold
With the Hold function you can hold the current
value on the display. Press the HOLD key (6) briefly
to hold the value and press HOLD again briefly to
close the function.
DC voltage measurements
Caution! Do not measure DC voltages when a
motor in the circuit is switched ON or OFF. This can
cause large voltage peaks that could damage the
meter.
1. Switch the function switch to the V position.
Insert the banana plug of the black testing wire in
the negative (3)COM connection and the plug of the
red wire in the positive (5) connection
2. Choose a value 1 step higher than the expected
measurement.
3. Touch the circuit to be tested with the test probes.
Ensure correct polarity (red wire to positive, black
wire to negative).
4. Read off the voltage on the display. The display
will show the correct decimals and value. When the
polarity is reversed the display will show (-) minus
for the value.
AC voltage measurements
Caution! Do not measure AC voltages when a
motor in the circuit is switched ON or OFF. This can
cause large voltage peaks that could damage the
meter.
1. Switch the function switch to the V position.
2. Choose a value 1 step higher than the expected
measurement.
3. Insert the banana plug of the black testing wire in
the negative (3)COM connection and the plug of the
red wire in the positive (5) connection.
4. Touch the circuit to be tested with the test probes.
Read off the voltage on the display. The display will
show the correct decimals, value and symbol.
Resistance measurements
Warning! To prevent electric shocks one must cut
the power supply to the unit to be tested and
discharge all capacitors before resistance
measurements are conducted. Remove the
batteries and take the plugs out of the plug socket.
1. Switch the function switch to the 2000k
position.
2. Insert the banana plug of the black testing wire in
the negative (3)COM connection and the banana
plug of the red testing wire in the (5) positive
connection.
3. Touch the circuit or part to be tested with the test
probe tips. It is best to disconnect a side of the part
to be tested so the rest of the circuit does not
interfere with the resistance measurement.
4. Read off the resistance on the display. The
display will show the correct decimals, value and
symbol. Lower the position if necessary until the
correct resolution is achieved.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Profile PIN-112 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Profile PIN-112

Profile PIN-112 Bedienungsanleitung - Holländisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info