566794
2
Zoom out
Zoom in
Vorherige Seite
1/3
Nächste Seite
MULTIMETER MEDIUM EN - 2
PIN-112
Continuity test
Warning! To avoid electric shocks never measure
connections with live circuits or wires.
1. Switch the function switch to the
position.
2. Insert the banana plug of the black testing wire in
the negative (3)COM connection and the banana
plug of the red testing wire in the positive (5)
connection.
3. Touch the circuit or wire you want to check with
the test probe tips.
4. If the resistance is lower than approx. 100 an
acoustic signal is sounded. The display will also
show the actual resistance.
Diode test
Warning! To avoid electric shocks do not test live
diodes.
1. Insert the banana plug of the black testing wire in
the negative (3) COM input and the banana plug of
the red test wire in the positive (5) connection.
2. Switch the switch to
3. Place the measuring heads on the diode to be
tested (red on (+) anode, black on (-) cathode). The
forward voltage is 400 to 700mV. The reverse
voltage is shown by “1”. Short-circuited equipment
displays a result of nearly 0 mV. An open device is
shown by “1” for both poles.
Measurements DC amperage
Caution! Do not conduct current measurements in
the 10A range that last longer than 30 seconds. If
they last longer than 30 seconds this can cause
damage to the meter and/or testing wires.
1. Insert the banana plug of the black test wire in the
negative (3) COM input
2. For current measurements to 200 mA DC switch
the function switch to the 200mA position and insert
the banana plug of the red test wire in the positive
(5) connection. If the value is too low you can lower
the position to 20mA or 2000μA.
3. For current measurements from 10 A switch the
function switch to 10A and insert the bananaplug of
the red testing wire in the 10A input (4).
4. Switch off the current in the circuit to be
measured. Break the circuit where you want to
measure the current.
5. Place the black measuring head on the negative
side of the circuit. Place the red measuring head on
the positive side of the circuit.
6. Put power on the circuit
7. Read the current on the display. For mA
measurements select a lower mA position with the
function switch to obtain a result with a higher
resolution. The display mentions the decimal point
and the value.
Transistor hFE measurements
1. Switch the range switch to the hFE position
2. Determine if the transistor is an NPN or PNP type
and place the emitter, basis and collector in the
openings in the hFE plug on the front panel.
3. The meter shows the approximative hFE value for
base current 10uA and VCA 2.8V
Replacing the battery
Warning! To prevent electric shocks you must
disconnect the testing wires from any power sources
before you open the cover of the battery
compartment.
1. When the batteries are nearly empty the
message "BAT" appears on the right of the display.
The battery must then be replaced.
2. Follow the instructions for replacing batteries.
See the paragraph on changing the battery in this
manual.
3. Dispose of old batteries at a collection point.
Warning! To prevent electric shocks you may not
use the meter until the cover of the battery
compartment has been replaced and fastened.
Replacing batteries
1. Disconnect the meter's testing wires.
2. Remove the rubber protection
3. Open the battery cover by removing the screw
with a screwdriver.
4. Place the battery in the compartment. Ensure the
correct polarity.
5. Replace the battery cover. Fasten the cover with
the screw.
Opm.: If your meter is not functioning properly you
must check the fusing and the battery to make sure
they are still in working order and correctly fitted.
Replacing the fusing
Warning! To prevent electric shocks you must
disconnect the testing wires from any power sources
before you open the cover of the fuse compartment.
1. Disconnect the testing wires from the meter and
all items to be tested.
2. Remove the rubber protection
3. Open the fusing compartment cover by removing
the screw in the cover.
4. Remove the old fusing from the compartment by
carefully pulling it out.
5. Place the new fusing in the holder.
6. Always use fusing of the correct size and
specification (10A/250V fast-reacting for the 10A
range).
7. Replace the fusing cover. Insert the screw and
tighten firmly.
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Profile PIN-112 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Profile PIN-112

Profile PIN-112 Bedienungsanleitung - Holländisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info