DOUBLE OPEN JAW
AC CLAMP MULTIMETER
1. SAFETY INFORMATION
The following safety information must be observed to insure
maximum personal safety while operating this meter.
1.1 Do not operate the meter if the body of meter or the test lead
look broken.
1.2 Check the main function dial and make sure it is at the correct
position before each measurement.
1.3 Do not perform resistance test on a live power system.
1.4 Do not apply voltage between the test terminals and test
terminal to ground that exceed the maximum limit record in this
manual.
1.5 Exercise extreme caution when measuring live systems with
voltage greater than 60V DC or 30V AC.
1.6 Change the battery when the " " symbol appears to avoid
incorrect data.
2. Panel Layout
1Rotary Switch: use this switch to select functions and ranges
2Data HOLD keyIn any range, push the key, the present
display value will be locked and the " DH " symbol will appear,
push it again to exit the HOLD function and the "DH" symbol will
disappear.
3 Back light button: Push the LIGHT button to light the
backlight, it will automatically go out after approximately 5
seconds.
4) LCD Display
5Ω Input Jack, COM Input Jack, V-Jack
3. SPECIFICATIONS
3.1 GENERAL SPECIFICATIONS
Display: 3 1/2 digit LCD with a max. reading of 1999.
Polarity: Automatic negative polarity indication.
Zero adjustment: Automatic.
Overrange indication: Only the "1" or "-1" display.
Low battery indication: " "
Safety Standards: The meter is up to the standards of IEC1010
Double Insulation, Pollution Degree 2, Overvoltage Category I.
Data hold: Push the DH switch to "ON" and the DH sign will
appear on the display.
Clamp opening size: 34mm.
Operating Environment:
Temperature: 040 (32104°F), humidity80%RH.
Storage Environment:
Temperature: -2060 (-4140°F), humidity90%RH.
Power supply: 3×1.5V AAA batteries.
Dimension: 179(H)×73(W)×26(D)mm.
Weight: Approx. 325g (including battery).
3.2 ELECTRICAL SPECIFICATIONS
Accuracy is specified for a period of 1 year after calibration and at
18°C to 28°C (64°F to 82°F) with relative humidity to 75%.
3.2.1 DC Voltage
Range
Accuracy
Resolution
500V
1.0% of rdg+5digits
1V
Overload protection: 500V DC/500Vrms AC
Impedance: 10MΩ
3.2.2 AC Voltage
Range
Accuracy
Resolution
500V
0~400V
1.2% of rdg+8 digits
1V
400~500V
1.8% of rdg+20 digits
1V
Average sensing, calibrated to rms of sine wave
Frequency: 50100Hz
Overload protection: 500V DC/500Vrms AC
Impedance: 10MΩ
3.2.3 AC Current
Range
Accuracy
Resolution
2A
3.0% of rdg+10 digits
1mA
20A
3.0% of rdg+10 digits
0.01A
400A
3.5% of rdg+10 digits
1A
Average sensing, calibrated to rms of sine wave
Frequency: 5060Hz
Overload protection: AC 400A within 60 seconds
3.2.4 Resistance
Range
Accuracy
Resolution
200Ω
±(1.5% of rdg+15 digits)
0.1Ω
20kΩ
±(1.0% of rdg+15 digits)
10Ω
2000kΩ
±(1.5% of rdg+15 digits)
1kΩ
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Profile PIN-146 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info