SENSOR INSTRUCTIONS
FUNCTION :
Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime
and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than
3LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to
the testing pattern.
SENS adjustable: It can be adjusted according to using location; low sensitivity with 5m for detection
distance; high sensitivity with 12m, it fits for large room.
Time-delay is added continually: When it receives the second induction signals after the first
induction, it will compute time once more on the rest of the first time-delay basic (set time).
Time-delay adjustment: It can be set according to the consumer’s desire. The minimum time is
10sec±3sec. The maximum is 7min±2min.
Good sensitivity Poor sensitivity
TEST :
Turn the SENS knob clockwise on the maximum, turn the TIME knob anti-clockwise on the minimum,
turn the LUX knob clockwise on the maximum(SUN).
When you switch on the power, the controlled load is not working. Preheat 30 seconds later, when the
sensor gets the induction signal, the load will be turned on. After the load is turned off, it will be
turned on again when the sensor gets induction signal within 5~15 sec.
After the first is out, make it sense again after 5~10sec. The load should work. When there is no
induction signals in the sensor, the load should be stopped working.
Turn LUX knob anti-clockwise on the minimum. If it is adjusted in the less than 3LUX(dark), the load
and sensor should not work when testing in daylight. If you cover the detection window with the
opaque objects (towel etc), the load work. Under no induction signal condition, the load should stop
working within 5-15sec.