Note: During an application, you can switch between the two rotation directions of the massage heads 5 and switch the heating function on and off according to your personal
preference.
The integrated automatic switch-off automatically switches the product off after the maximum operating time of 15 minutes. This is not a malfunction. After the automatic switch-
off, you can immediately switch the product on again and use it (e.g. for massages on other body areas, other people). However, make sure not to exceed the maximum usage time
of 15 minutes per body zone.
You operate the product with the control panel 7 (see fig. A).
Press the on/off button 9 once to switch on the product. The signal light above the on/off button 9 lights up red, indicating that the product is switched on.
To switch the product off, press the power button 9 again. The red signal light above the power button 9 turns off, indicating that the product is switched off.
To start the massage function, press the 10 button once or the 11 button once when the product is on. The signal light above the corresponding button lights up green,
indicating that the massage heads 5 rotate in the corresponding direction 10 Change of direction: the massage heads 5 rotate in the opposite direction.
11 Direction change button: The massage heads 5 rotate in the opposite direction.
To switch on the heating function, press the heating button 6 when the product is switched on. The signal light above the heating button 6 lights up red to indicate that the heating
function is on.
To switch off the heating function, press heating button 6 again. The red signal light above the heating button 6 goes out, indicating that the heating function has been switched off.
Using the product without the top
Improper use of the product may result in damage to the product.
Do not use the product sitting down. Never lie or sit on the product. the product.
Open the zip 2 completely (see fig. C).
Remove the upper part 13 upwards from the lower part 8.
Plug the appliance plug 4 into the socket 3.
Plug the mains adapter 12 into a socket to establish the mains connection for the product.
Place the lower part 8 with the massage heads 5 on the body parts such as the shoulders or back and then gently lean against the backrest of the chair (see fig. B). The lower part 8
is now between your body and the backrest of the chair. Take care not to lean too hard against the base 8 during use to avoid overloading the product.
Switch the product on at control unit 7 and operate it during use with control unit 7 (see section “Operating the product with the control unit”).
Switch the product off at control unit 7 to cancel the massage in progress. Or:
Use the product for a maximum of 15 minutes.
After 15 minutes of use, the product switches off automatically (automatic switch-off). Unplug the mains adapter 12 to disconnect the product from the mains.
Unplug the appliance 4 from the socket 3 .
CLEANING CARE AND STORAGE
Ensure that no water or other liquids get into the interior of the product, the control panel or the power supply unit.
7 or the plug-in power supply unit 12
Unplug mains adapter 12 from the mains outlet before cleaning.
Let the product cool down completely.
Do not clean the product in the dishwasher.
Do not use aggressive detergents or hard brushes!
Do not bleach.
Do not use bleaching agents (such as heavy-duty detergents).
Do not tumble dry.
Do not iron.
Do not dry clean.
Soft wash programme 30 °C
Open the zip 2 completely and remove the top part 13 from the bottom part 8 (see fig. C).
Clean the bottom part 8 and the control part 7 with a slightly damp cloth and water.
For heavier soiling, you can also use a light soap solution. However, always ensure that the cloth is only slightly damp to prevent moisture from penetrating the product or the
control panel 7.
Clean the top 13 by washing it by hand or in the washing machine (gently at 30 °C).
Allow the top 13 to dry completely.
After cleaning, reassemble the top 13 and bottom 8 and close the zip 2 .
Protect the product from direct sunlight.
Do not place objects or anything similar on the product.
Store the product out of the reach of children, tightly closed and at a storage temperature between 5 and 20 °C (room temperature). room temperature).
Store the device and all parts in the original packaging in a dry environment if you are not going to use it for a long time.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für QLT HAC22043 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.