A. Blowers
1. Convection Blower
PART NUMBER: 812-4900
NOTE: The convection blower must be removed before
the exhaust blower can be removed.
Side Screws,
Loosen Do Not
Remove
Side Screws,
Loosen Do Not
Remove
Remove back screws and
bend top back leaving it
attached at the bottom
Figure 25.1
Remove 6 screws
Figure 25.2
Figure 25.3
Loosen (do not remove) 2
screws on each side and lift
off blower housing
Remove left side
panel and disconnect
blower wires
Convection Blower
& Housing
5 5 Service Parts Replacement
2. Combustion Blower
PART NUMBER: 812-4400
a. Turn down thermostat, let appliance completely cool
and then unplug appliance before servicing.
b. The convection blower is located at the bottom rear
of the appliance and is housed inside a screen box.
Remove the 2 screws facing forward in the center of
the blower chamber at the very back of the appliance.
c. If an outside air kit is installed on the appliance, these
screws attach the intake air channel piece of the
outside air kit to the appliance. Remove the 2 screws
and pull backwards on the channel and it will slide
down and away from the appliance. The air channel,
collar and outside air hose will be removed as one
piece.
d. There are 2 screws on each side of the housing.
Loosen all 4 screws, but do not remove them. Lift
the blower housing up slightly and slide towards you
(Figure 25.3).
e. Remove the left side panel by loosening 2 screws
(do not remove) and pull side panel away. Unplug
the 2 black blower wires by disconnecting the spade
connectors.
f. To remove blower from the housing, remove 2 screws
in the front of the housing and very carefully bend the
2 housing sides out and bend the back of the housing
away from the blower. This allows for room to access
the back 2 screws and nuts (4 total) that is securing
the blower to the housing.
g. Remove blower and replace with new blower.
h. Re-install in reverse order.
a. Turn down thermostat, let appliance completely cool
and then unplug appliance before servicing.
b. Remove both side curtains by loosening 2 screws (do
not remove) and pull side panels away.
c. Remove 4 screws from the back screen and pivot
the top of the screen toward you leaving the bottom
attached to appliance (Figure 25.1).
d. Remove 2 screws to remove the thermostat block
and disconnect the 2 yellow wires.
e. Remove the 2 screws from the power inlet and rotate
it through the hole and out of the screen, leaving the
wires attached.
f. Disconnect the vacuum hose and both wires (orange
and red) from the vacuum switch attached to the rear
screen.
g. Remove both wires from exhaust blower (blue and
double white).
h. Remove 6 screws using a athead screwdriver or a
1/4” nut-driver. Retain screws for use on replacement
blower (Figure 25.2).
i. Remove exhaust blower and gasket.
j. Install new gasket and blower. Discard blower housing
if not needed.
k. Re-install in reverse order.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Castile - Pellet wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info