815522
29
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
29 12/237021-802L
When describing the location of a
component, it is always AS YOU FACE
THE FRONT OF THE APPLIANCE.
A. Component Functions
1. Control Box
a. The control box is located on upper right side of
appliance, behind the right side panel and above the
vacuum switch.
b. There is a light located inside of the control box. The
internal light will turn green when the appliance has
reached a temperature of 200°F (93°C) in the re pot
and will turn red when it reaches 600°F (315°C).
c. There is also an internal blue light located in the
upper left corner of the control box. When you plug
in the appliance the blue light will automatically start
blinking 6 times in a row for 60 seconds and then will
stop.
NOTE: Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the control box
you must rst unplug the appliance.
6 6 Reference Materials
8. Heat Output Switch: The heat output switch is located
on the upper right rear panel. The function of the heat
output switch is to regulate the burn rates; low, medium
and high settings.
9. Hopper Switch: The hopper switch is located in the
upper right hand corner of the hopper. This switch is
designed to shut down the feed motor whenever the
hopper lid is opened.
10. Igniter: The igniter is mounted on the base of the re
pot. Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets.
11. Junction Box And Wiring Harness: The junction box
is located on the right side of the appliance, behind the
right side panel. The junction box and wiring harness
are replaced as one component.
12. Power Supply: The power outlet is located behind
the control box on the back of the appliance, lower left
corner. Check the wall receptacle for 120 volt, 60 Hz
(standard current). Make sure the outlet is grounded
and has the correct polarity. A good surge protector is
recommended.
13. Red Call Light: The red call light is on the side of the
junction box, next to the fuse. The function of the red
call light is to indicate that the thermostat is calling for
heat.
14. Reset Button: The reset button is located on the back
of the appliance in the upper right corner below the heat
output control switch. The function of the button is to
momentarily open the thermostat circuit, which restarts
the system.
15. Thermocouple: The thermocouple is located on
top of the re pot inside the thermocouple cover
(ceramic protection tube). The thermocouple sends a
millivolt signal to the control box indicating the preset
temperatures of the green and red lights have been
obtained.
16. Thermostat: The appliance is designed to run on a 12
volt AC thermostat. The heat anticipator should be set
on the lowest setting available.
2. Convection Blower: The convection blower is mounted
at the bottom rear of the appliance. There are 2 impellers,
one on each side of the motor. The convection blower
pushes heated air through the heat exchange system
into the room.
3. Exhaust Blower: The exhaust blower is mounted on
the right side of the appliance. The exhaust blower is
designed to pull the exhaust from the appliance and
push it out through the venting system.
4. Feed System: The feed system is located on the right
side of the appliance and can be removed as an entire
assembly. The assembly includes the feed motor,
mounting bracket, bearing and feed spring (auger). The
hollow feed spring (auger) pulls pellets up the feed tube
from the hopper area and drops them down the feed
chute into the re pot.
5. Fire pot: The re pot is made of high quality ductile iron
and has a cleaning pull-out rod. The oor of the re pot
opens for cleaning when you pull out the rod. Be sure
that the oor returns to a completely closed position or
your appliance will not operate properly.
6. Fuse: The fuse is located on the front of the junction
box next to the red call light. The fuse will blow should a
short occur and shut off power to the appliance.
7. Heat Exchangers: The heat exchangers transfer hot air
from the exhaust system into convection air. Remove the
stainless steel top bafe to access the heat exchangers.
There are 2 clean out rods located under the heat
exchangers.
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Castile - Pellet wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info