815525
26
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
26 04/217027-805J
A. Blower
1. Combustion (Exhaust) Blower Replacement
PART NUMBER: 812-3381
a. Prep appliance from the blower removal:
i. Disconnect the appliance from the electrical outlet.
ii. Remove panel set and disconnect ue.
iii. Pull appliance out onto the hearth.
iv. Remove the right-side access panel, then slide out
the right-side panel of the appliance, held in place
with 2 screws, to expose the exhaust blower.
b. Remove existing blower (Figure 26.1):
i. Use the 11/32” wrench or nut driver to loosen and
remove the (6) nuts holding the motor mount plate
to the blower housing on your appliance.
ii. Remove the washer from beneath the terminal
ring on the grounding wire.
iii. Pull motor/mounting plate from blower housing.
iv. Scrape o󰀨 the old gasket material from
blower housing.
c. Install new blower:
i. The blower and blower housing is shipped as a
appliance in this kit. It is necessary to separate
them at this point.
ii. Use 11/32” wrench or nut driver to loosen and
remove the (6) nuts holding the motor mount plate
to the blower housing.
iii. Remove the washer from beneath the terminal
ring on the grounding wire.
iv. Pull motor/mounting plate from blower housing
and discard or set aside the blower housing.
v. Carefully remove gasket from new housing and
set onto the appliance blower housing.
d. Reinstall blower to blower housing:
i. Install blower on housing ensuring that wiring exits
at the 12 o’clock position. Place washer and then
grounding wire on nearest mounting plate stud.
ii. Use nuts removed in step A1 to secure blower to
housing.
iii. Reconnect wiring. Use Jumper wire if necessary.
Reconnect power supply.
e. Re-install appliance:
i. Reassemble right side panel to appliance with 2
screws previously removed.
ii. Push appliance back into the hearth.
iii. Reconnect ue and re-install panel set; plug in
appliance to electrical outlet.
Figure 26.1
Blue Wire
White Wires
Housing Bolts
Blower Mounting
Screws
5 5 Service Parts Replacement
2. Convection Blower Replacement
PART NUMBER: 812-4900
a. The blower is located at the bottom rear of the insert.
If an outside air kit is also installed, you will rst need
to remove the outside air ange by removing the 2
screws using a Phillips head screwdriver. You do not
need to remove the ex pipe from the ange.
b. Remove panel set and disconnect ue.
c. Pull appliance out onto the hearth.
d. Remove left access panel and then slide out left side
panel of appliance to expose the convection blower.
Loosen wing nut on the vacuum switch and remove
vacuum switch to allow room to remove the blower.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white
and the wires from the blower are black.
f. The blower is held in place with a magnet. A wing
nut and plate are installed at the factory for shipping
purposes only. This can be removed once the
appliance is installed. Lift up blower from the magnet
and remove.
g. Re-install in reverse order.
Shock Risk.
Do NOT remove grounding prong
from plug.
Plug directly into properly grounded 3
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front
of appliance.
CAUTION
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Classic Bay 1200 - Pellet - Insert wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Classic Bay 1200 - Pellet - Insert

Quadra-Fire Classic Bay 1200 - Pellet - Insert Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info