815525
29
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
29 04/217027-805J
A. Component Function
1. Control Box
a. The control box is located on right side of appliance,
behind the right side panel.
b. There is a light located inside of the control box. The
internal light will turn green when the appliance has
reached a temperature of 200°F (93°C) in the re pot
and will turn red when it reaches 600°F (315°C).
c. There is also an internal blue light located in the
upper left corner of the control box. When you plug
in the appliance the blue light will automatically start
blinking 1 blink every 10 seconds for 60 seconds and
then will stop.
NOTE: Do NOT open the control box. This will void the
warranty. If you need to plug in or remove the control box
you must rst unplug the appliance.
When describing the location of a
component, it is always AS YOU FACE
THE FRONT OF THE APPLIANCE.
6 6 Reference Materials
8. Heat Output Switch: The heat output switch is located
on the right side of rebox, behind right side panel. The
function of the heat output switch is to regulate the burn
rates; low, medium and high settings.
9. Hopper Switch: The hopper switch is located in the
upper right hand corner of the hopper. This switch is
designed to shut down the feed motor whenever the
hopper lid is opened.
10. Igniter: The igniter is mounted on the base of the re
pot. Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets.
11. Junction Box And Wiring Harness: The junction box
is located on the right side of the appliance, behind the
right front access panel. The junction box and wiring
harness are replaced as one component.
12. Power Supply: The power outlet is located on the
right side of the appliance. Check the wall receptacle
for 120 volt, 60 Hz (standard current). Make sure the
outlet is grounded and has the correct polarity. A good
surge protector is recommended. When operating with
a generator you need at least 600 watts of power, or
with an inverter at least 800 watts of power, available
for the appliance during the start cycle.
13. Red Call Light: The red call light is on the right side
behind the right side panel. The function of the red call
light is to indicate that the thermostat is calling for heat.
14. Reset Button: The reset button is located on the right
side of rebox behind right side panel. The function of
the reset button is to momentarily open the thermostat
circuit, which restarts the system.
15. Thermocouple: The thermocouple is located on
top of the re pot inside the thermocouple cover
(ceramic protection tube). The thermocouple sends a
millivolt signal to the control box indicating the preset
temperatures of the green and red lights have been
obtained.
2. Convection Blower: The convection blower is mounted
at the bottom rear of the appliance. There are 2 impellers,
one on each side of the motor. The convection blower
pushes heated air through the heat exchange system
into the room.
3. Combustion (Exhaust) Blower: The combustion blower
is mounted on the left side of the appliance behind the
left side panel. It is accessible either when the insert
is pulled out onto the hearth or from both hinged side
openings. The blower is designed to pull the exhaust
from the appliance and push it out through the venting
system.
4. Feed System: The feed system is located behind the
rebox and can be removed as an entire assembly. The
assembly includes the feed motor, mounting bracket,
bearing and feed spring (auger). The hollow feed spring
(auger) pulls pellets up the feed tube from the hopper
area and drops them down the feed chute into the re
pot.
5. Fire pot: The re pot is made of high quality ductile iron
and has a cleaning pull-out rod. The oor of the re pot
opens for cleaning when you pull out the rod. Be sure
that the oor returns to a completely closed position or
your appliance will not operate properly.
6. Fuse: The fuse is located on the right side of the appliance
behind the side panel. The fuse will blow should a short
occur and shut o󰀨 power to the appliance.
7. Heat Exchangers: The heat exchangers transfer heat
from the exhaust system into convection air. There are 2
clean out rods located under the heat exchangers.
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Classic Bay 1200 - Pellet - Insert wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Classic Bay 1200 - Pellet - Insert

Quadra-Fire Classic Bay 1200 - Pellet - Insert Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info