LISTED ROOM APPLIANCE, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD . "For Use with
Solid Wood Fuel Only" / APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE COMBUSTIBLE SOLIDE, POUR USAGE
DANS LES MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec Bois Solide Seulement"
PREVENT HOUSE FIRES / PRÉVENTION DES FEUX DE MAISON
Install and use only in accordance with manufacturer's installation and operating instructions. Contact local building or fire
officials about restrictions and installation inspections in your area. Do not obstruct the space beneath appliance. WARNING
- For Mobile Homes: Do not install in a sleeping room. An outside combustion air inlet must be provided and unrestricted
while unit is in use. The structural integrity of the mobile home floor, ceiling and walls must be maintained. The appliance
needs to be properly grounded to the frame of the mobile home. Components required for mobile home installation: Outside
Air Kit, Part Number OAK-ACC. Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling and maximum offsets. Inspect and clean chimney frequently - Under Certain
Conditions of Use, Creosote Buildup May Occur Rapidly. Do not connect this unit to a chimney serving another appliance.
Optional Blower, Part BK-ACC. Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz. Route power cord away from unit. Do not route
cord under or in front of appliance. DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace
glass only with 5mm ceramic available from your dealer. Do not use grate or elevate fire. Build wood fire directly on hearth.
Do not overfire - if appliance or chimney connector glows, you are overfiring. Operate only with the fuel loading door closed.
Open only to add fuel to the fire. / Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant.
Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation
dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil. AVIS - Pour Les Maisons Mobiles : Ne pas
installer dans une chambre à coucher. Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué
lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit être
maintenue intacte. L'appareil de chauffage doit être fixé à la charpente de la maison mobile. Les composants requis pour
l'installation des maisons mobiles: Assemblage d'air extérieur, Numéro de Pièce OAK-ACC. Référez vous aux instructions
du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond
combustibles, et les compensations maximums. Inspectez et nettoyez la cheminée fréquemment. Sous certaines conditions,
il se peut que la créosote s'accumule rapidement. Ne pas connecter cet appareil à une cheminée servant un autre appareil.
tVentilateur Optionnel, Pièce BK-ACC. Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz. Éloignez le fil électrique de
l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. DANGER : Il y a risque de décharge
électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre
céramique de 5 mm disponible chez votre fournisseur. N'élevez pas le feu. Bâtissez le feu de bois directement sur l'âtre. Ne
pas surchauffer. Si l'appareil de chauffage ou le tuyau de cheminée rougissent, vous surchauffez. Opérez l'appareil
seulement lorsque la porte de chargement est fermée. Ouvrez la porte seulement lorsque vous devez ajouter des
combustibles dans le feu.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission standards using crib wood at 1.9 G/HR
This wood heater needs periodic inspection and repair for proper operation. Consult the
owner’s manual for further information. It is against federal regulations to operate this wood
heater in a manner inconsistent with the operating instructions in the owner’s manual.
2023 2024
Dec.Nov.Oct.Sept.Aug.JulyJuneMayApr.Mar.Feb.Jan.
2025
FLOOR PROTECTION:
Floor protector must be a 3/8 (9.5mm) inch min. thickness,
non-combustible material or equivalent, extending beneath
heater and to front/sides/rear as indicated on the diagram
below. Exception: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS
AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.
VENT SPECIFICATIONS: / SPÉCIFICATIONS DE LA VENTILATION :
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
/ MUR SIMPLE : De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a masonry chimney and the referenced clearances. / MUR DOUBLE : De six (6 inches)
(152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de briques, avec espaces libres alloués.
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a spark arrestor. Apply double wall clearances below when installing unit. / MAISON MOBILE : Utiliser
un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double comme mentionné ci-bas.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters) / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar. / REMARQUE : Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.
7033-354F
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES
BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS
.
ATTENTION:
PROTECTION DU PLANCHER:
Le protecteur de plancher doit être d'un minimum de 3/8
inch (9.5mm) d'épaisseur, de matériel incombustible ou
équivalent, s'étendant du dessous de l'appareil de
chauffage à l'avant, aux cotés et à l'arrière comme indiqué
sur le diagramme suivant. Exception : Les protections
incombustibles du plancher doivent s'étendre en dessous
du conduit de cheminée lorsqu'installées avec une
ventilation à l'horizontale et s'étendre de 2 inches (51mm)
de chaque côté.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Manufactured by:
Fabriqué par :
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1243mm
(49")
minimum
1041mm (41") minimum
Made in U.S.A. of US and imported parts.
/ Fabriqué aux États-Unis-d’Amérique par
des pièces d’origine américaine et pièces
importées.
31M-ACC-C DISCOVERY-II-C
352 Mountain House Road,
Halifax, PA 17032
www.quadrafire.com
Serial No. / N° de série
HF
BARCODE LABEL
TESTED TO:/ TESTÉ À :
ASTM E2515, ASTM E2780, UL1482, ULC S627-00.
R
3100 ACC Series-C
Report / Rapport
0061WS066S
0061WS066E
16" from glass
8"
USA
Fuel loading door
Millennium 31-5/8" Min
39”
minimum
I
NSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP / INSTALLATION : ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE
A B C D E F G H
Discovery-II-C 18.25 (464) 11.75 (298) 28.5 (724) 16 (406) 8 (203) 20 (508) 48 (1220) 12 (305)
31M-ACC-C 18.25 (464) 11.75 (298) 28.5 (724) 16 (406) 8 (203) 20 (508) 48 (1220) 12 (305)
DOUBLE WALL PIPE /
CONDUIT DU MUR DOUBLE
Discovery-II-C 13.5 (343) 6.5 (165) 25 (635) 13 (330) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
31M-ACC-C 13.5 (343) 6.5 (165) 25 (635) 13 (330) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
INSTALLATION: 90° ELBOW OFF TOP OF STOVE THROUGH BACKWALL / INSTALLATION: 90° DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE
SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE
Discovery-II-C 15 (381) 8.5 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1220) 12 (305)
31M-ACC-C 15 (381) 8.5 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1220) 12 (305)
DOUBLE WALL PIPE /
CONDUIT DU MUR DOUBLE
Discovery-II-C 11 (279) 4.5 (114) 20.5 (521) 8.5 (216) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
31M-ACC-C 11 (279) 4.5 (114) 20.5 (521) 8.5 (216) 6.5 (165) 18.5 (470) 48 (1220) 9 (229)
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a
spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove clearances. /
INSTALLATION : ALCÔVE -
Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de
raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de
48 pouces (1219mm) et les dégagements en alcôve référencés
.
DOUBLE WALL PIPE / CONDUIT DU MUR DOUBLE
Discovery-II-C
14.75 (375) 8.25 (210) 26.5 (673) 14.5 (368) N/A N/A 48 (1220)
*
31M-ACC-C
14.75 (375) 8.25 (210) 26.5 (673) 14.5 (368) N/A N/A 48 (1220)
*
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Factory-built chimney. / *Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650°C cheminée bâtit en usine.
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED / VOIR LE FABRICANT POUR LES ESPACES LIBRES DES CONDUIT - PAS TESTÉ
90° OFF TOP
UP & OUT CEILING CLEARANCE
ESPACE LIBRE DU DESSUS DE
L'APPAREIL AU PLAFOND AVEC
90° DE COURBURE
STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU
PLAFOND
G
H
G
H
GA
B
ALCOVE SIDE VIEW /
VUE DE CÔTÉ DE
L'ALCÔVE
B
GA
ALCOVE TOP VIEW /
VUE DU HAUT DE
L'ALCÔVE
C
D
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
AB
C
D
CORNER INSTALLATION/
INSTALLATION DU COIN
E
F
E
F
A. Exemple d’étiquette de numéro de série/de sécurité
Date de fab.
compétentes.