A. Sample of Serial Number / Safety Label
LOCATION:UNDERASHLIP,PULLOUTTOVIEW
NOTE: Clearances may only be reduced by means approved by the regulatory authority having
jurisdiction
and Welcome to the Quadra-Fire Family!
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and operating
instructions.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling.
WARNING - For Mobile Homes: Do not
install in a sleeping room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the mobile home floor, ceiling
and walls must be maintained. The insert must be properly grounded to the frame of the
mobile home. A complete relining of the chimney system with a 6 inch (152mm) diameter
listed stainless liner is required. Must be equipped with a spark arrestor cap. Outside Air
comes standard on the insert and must be installed before operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to national
and/or local codes. Do not remove brick or mortar to accommodate insert. Installation
requires a 5 foot minimum length of a starter pipe into existing chimney with airtight face
seal. A full reline with listed liner strongly reccomended.
Install only on a non-combustible hearth.
Approved for installation and use in factory built zero-clearance fireplaces conforming to
minimum fire chamber specifications. A complete relining of the chimney system with a 6
inch (152mm) diameter listed stainless liner is required.
In Canada a full length 6 inch (152mm) S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use, creosote
buildup may occur rapidly.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route
power cord away from unit. Do not route cord under or in front of appliance. Electrical
Rating: 115 VAC 1.4 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on hearth (firebrick).
Do not
overfire. If heater or chimney connector glows, you are overfiring.
Operate only with doors
closed. Open only to add fuel to the fire. Replace glass only with 5mm ceramic available
from your dealer.
DO NOT REMOVE THIS LABEL
HOT WHILE IN
OPERATION DO NOT
TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE
NAMEPLATE AND INSTRUCTIONS.
CAUTION:
Factory-Built Floor
Protection under Hearth
Extension
Thermal & Ember Protection
Floor height 0 to 4.5 inches below
Insert Base: Materials with R value of
2.9 required.
Ember Protection Only
Greater than 4.5 inches below Insert
Base.
LISTED ROOM HEATER, SOLID FUEL TYPE
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
Made in U.S.A. of US and
imported parts.
7094-800A
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 crib wood particulate emission standards at 1.9 g/hr for single burn rate heaters.
This single burn rate wood heater is not approved for use with a flue damper.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
Mfg by:
352 Mountain House Road
Halifax, PA 17032
www.quadrafire.com
R
Serial No. / N° de série
HF
BARCODE LABEL
EXPEDITION I
CONFORMS TO UL STD 1482 AND CERTIFIED TO ULC STD S628
21-670
21-661
Side Wall
FF
Fuel Door
Insert
BB
Fascia
or Trim
Maximum Mantel Depth - 12 inch (305mm)
Mantel
Hearth Extension
AA
C
C
D
D
E
E
Minimum Clearances To Combustible Material
Masonry, Heat Circulating & Factory-Built
Refer to Clearances on other label for Canada
A Sidewall to Center of Appliance 24.5 in.
B Mantel to Bottom of unit 44.75 in.
C Top Trim to Bottom of unit 42.5 in.
D Side Trim to Center of Appliance 23.75 in.
E Hearth Extension from Glass 16 in.
F H
earth Extenson from Fuel Loading Door
8 in.
USA ONLY
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
2022 2023 2024
SAMPLE
Test Lab &
Report Number
Mfg Date
Serial Number
Model Name
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Expedition I wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Expedition I

Quadra-Fire Expedition I Bedienungsanleitung - Französisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info