Batteries and Charging
Your power chair uses two long-lasting, 12-volt, deep-cycle
batteries. These batteries are sealed and maintenance
free. Since they are sealed, there is no need to check the
electrolyte (fluid) level. Deep-cycle batteries are designed
to handle a longer and deeper discharge. Though they are
similar in appearance to automotive batteries, they are not
interchangeable. Automotive batteries are not designed to
handle a long, deep discharge, and also are unsafe for use
in power chairs.
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
Contact your Quantum Rehab Provider if you have any
questions regarding the batteries in your power chair.
Always use two batteries of the exact same type,
chemistry, and amp-hour (Ah) capacity. Refer to
specifications table in this manual and in the manual
supplied with the battery charger for recommended type
and capacities.
Charging the Batteries
The battery charger is essential in providing long life for your
power chair batteries. It is designed to optimize your power
chair’s performance by charging the batteries safely, quickly,
and easily.
PROHIBITED!
MANDATORY!
WARNING!
PROHIBITED! Removal of grounding prong can
create electrical hazard. If necessary, properly
install an approved 3-ponged adapter to an
electrical outlet having 2-pronged plug access.
PROHIBITED! Never use an extension cord to
plug in your battery charger. Plug the charger
directly into a properly wired standard electrical
outlet.
PROHIBITED! Do not allow unsupervised
children to play near the power chair while
the batteries are charging. Quantum Rehab
recommends that you do not charge the
batteries while the power chair is occupied.
MANDATORY! Read the battery charging
instructions from this manual and in the manual
supplied with the battery charger before
charging the batteries.
WARNING! Explosive gases may be generated
while charging the batteries. Keep the power
chair and battery charger away from sources
of ignition such as flames or sparks and
provide adequate ventilation when charging the
batteries.
WARNING! You must recharge the power chair
batteries with the supplied off-board battery
charger. Do not use an automotive-type battery
charger.
WARNING! Inspect the battery charger, wiring,
and connectors for damage before use. Contact
your Quantum Rehab Provider if damage is
found.
WARNING! Do not attempt to open the battery
charger case. If the battery charger does not
appear to be working correctly, contact your
Quantum Rehab Provider.
WARNING! Be aware that the battery charger
case may become hot during charging. Avoid
skin contract and do not place on surfaces that
may be affected by heat.
WARNING! If the battery charger is equipped
with cooling slots, then do not attempt to insert
objects through these slots.
WARNING! If the battery charger has not been
tested and approved for outdoor use, then do
not expose it to adverse or extreme weather
conditions. If the battery charger is exposed to
adverse or extreme weather conditions, then it
must be allowed to adjust to the difference in
environmental conditions before use indoors.
Refer to the manual supplied with the battery
charger for more information.
BATTERIES AND CHARGING
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quantum Jazzy 1450 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quantum Jazzy 1450

Quantum Jazzy 1450 Bedienungsanleitung - Deutsch - 28 seiten

Quantum Jazzy 1450 Bedienungsanleitung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info