CARE AND MAINTENANCE
13. Connect the battery harness to the new front battery
according to the battery wiring diagram. See figure 21.
14. Connect the battery harness to the new rear battery
according to the battery wiring diagram. See figure 21.
Make sure you tighten the fasteners so that the
connections are secure.
15. Install the new rear battery by lowering it into the power
base. Ensure the actuator is straight up and down next
to the rear battery. Connect the quick release battery
connectors to the new rear battery.
16. Install the new front battery by sliding it into the front
of the power base. Connect the quick release battery
connectors to the new front battery.
17. Reinstall the top cover by sliding the rear of the top cover
under the lip of the rear door and then sliding into place.
18. Reinstall the front cover.
19. Return the seat to an upright position.
20. Reinstall the detent pin into the top of the actuator and
ensure that it is secure. See figure 4.
21. Reinstall six (6) Phillips flat head screws if seat pan was
removed.
22. Tighten the rear pivot hardware.
23. Charge the batteries. See “Batteries and Charging.
Battery Replacement
A battery wiring diagram is printed on a decal located on
the front cover. See the specification table for correct battery
specifications.
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
The batteries in your power chair should only be
serviced or replaced by a Quantum Rehab Provider or a
qualified technician.
Do not replace batteries when seat is occupied.
Power chair batteries are heavy. See specifications
table. If you are unable to lift that much weight, be sure
to get help. Use proper lifting techniques and avoid
lifting beyond your capacity.
Do not mix old and new batteries. Always replace both
batteries at the same time.
Keep tools and other metal objects away from the battery
terminals. Contact with tools can cause electrical shock.
To replace the batteries:
1. Turn off the power to the controller.
2. Make sure that the power chair is in drive mode. See
“Your Power Chair.
3. Loosen the rear pivot hardware until the Nylock nut is a
few threads from being removed.
4. Remove the detent pin from the top of the actuator. See
figure 4. If there is any difficulty in reaching the pin from
under the seat, the seat pan may be removed. Remove
six (6) Phillips flat head screws to remove the seat pan.
5. Pivot the seat toward the rear of the power chair and
support the seat in this position. Take care to ensure that
the recline actuator does not damage the rear door of
the power chair while the seat is pivoted rearward.
6. Remove the front cover by squeezing the release
handles (see figure 21) and lifting the front cover up
and away from the power base.
7. Remove the top cover by lifting it straight up and off of
the power chair.
8. Disconnect the actuator harness.
9. Disconnect the quick release battery connectors. See
figure 1.
10. Remove the front battery from the power base by sliding
it forward and out of the power base.
11. Remove the rear battery by lifting it up and out of the
power base.
12. Disconnect the battery harness from each battery.
PROHIBITED!
WARNING!
WARNING!
MANDATORY!
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quantum Q4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quantum Q4

Quantum Q4 Bedienungsanleitung - Deutsch - 32 seiten

Quantum Q4 Bedienungsanleitung - Holländisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info