Hygiene when being reused:
When the chair is to be reused, it should be prepared carefully,
and be wiped and treated with spray disinfectant on all surfaces
which could come into contact with the user.
If you need to do this quickly, you must use a liquid, alcohol-
based disinfectant suitable for medical products and devices.
Please pay attention to the manufacturer’s instructions of the
disinfectant you are using.
Wheelchair pulls to one side
Check tyre pressure
Check to make sure wheel turns easily (bearings, axle)
Check the castor angle
Check to make sure both casters are making proper contact
with the ground
Casters begin to wobble
Check the castor angle
Check to make sure all bolts are secure; tighten if necessary
(see the section on torque).
Check to make sure both casters are making proper contact
with the ground
Wheelchair squeaks and rattles
Check to make sure all bolts are secure; tighten if necessary
(see the section on torque).
Apply small amount of lubrication to spots where movable
parts come in contact with one another
Wheelchair begins to wobble
Check angle at which castors are set
Check tyre pressure
Check to see if rear wheels are adjusted differently
10.0 Trouble shooting
11.0 Disposal / Recycling of Materials
NOTE:If the wheelchair has been made available to you free of
charge, then it does not belong to you. If it is no longer required,
follow any instructions given by the organisation issuing the
wheelchair in order that it may be returned to them.
The following information describes the materials used in the
wheelchair in relation to their disposal or re-cycling of the
wheelchair and its packaging.
Specific waste disposal or recycling regulations may be in force
locally and these should take into consideration when disposal
arrangements are made. (This may include the cleaning or
de-contamination of the wheelchair before disposal.)
Aluminium: Castor forks, wheels, sideguards of the chassis,
armrests, frame, footrest, push handle
Steel: Fasteners, QR axle
Plastic:Handgrips, tube plugs, castor wheels, footplates,
armpads
Packaging:Low density polythene bag, cardboard box
Upholstery:Woven polyester with PVC coatings and expanded
combustion modified foam.
Disposal or recycling should be done through a licensed agent
or authorised place of disposal. Alternatively your wheelchair
may be returned to your dealer for disposal.
9.0 Maintenance and care
If your wheelchair should ever get wet, please dry it afterwards.
A small amount of sewing-machine oil should be applied to
quick-release axles approximately every 8 weeks. Depending
on the frequency and type of use, we recommend taking your
wheelchair to your authorised dealer every 6 months to have it
inspected by trained personnel.
If you want to store the wheelchair for a long period of time,
then no further measures are required. Make sure that the
wheelchair is stored at room temperature in a dry place which
is protected from strong sunlight. Before using it again, the
wheelchair should be checked by an authorised dealer.
CAUTION!
Sand and sea water (or salt in the winter) can damage the
bearings of the front and rear wheels. Clean the wheelchair
thoroughly after exposure.
The following parts can be removed and sent back to the
manufacturer/dealer for repair:
• Rear wheels
Armrest
Anti-Tip tubes
These components are available as spare parts. For further
information, please see the spare parts catalogue.
Hygiene measures when being re-used:
Prior to the wheelchair being re-used, it must be carefully
prepared. All surfaces which come into contact with the user
must be treated with a disinfection spray.
To do this, you must use a disinfectant from the DGHM list, e.g.
Antifect Liquid (Schülke & Mayr) for rapid alcohol-based
disinfection for medical products and medical devices, which
must be disinfected quickly.
Please pay attention to the manufacturer’s instructions of the
disinfectant you are using.
In general, a complete disinfection cannot be guaranteed on
seams. We therefore recommend that you dispose of seat and
back slings to avoid microbacterial contamination with active
agents according to § 6 infection protection law.
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quickie Life i wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info