5500 Series Rotor Operation Guide
Full/Part Circle Operation
(Refer to Figure 1 on fold-out page)
All 5500 Series rotors are factory preset to part-circle at approximately 180 degrees.
Full-Circle Operation
Insert a flat blade screwdriver into the center adjustment slot on the top of the rotor. Turn the
screwdriver clockwise so the blade is aimed toward the full-circle icon.
Part-Circle Operation
Insert a flat blade screwdriver into the center adjustment slot on the top of the rotor. Turn the
screwdriver counter clockwise so the blade is aimed toward the part-circle icon. Use the following
instructions to adjust the arc settings.
Arc Adjustment
Important facts:
The rotor may be adjusted to any arc between 50° - 330° and full circle.
Both right and left edges of the arc can be independently adjusted.
One full 360 degree turn of the arc adjustment screw will change the arc edge approximately 120
degrees. Three full turns of the arc adjustment screw will rotate the trip edge completely around to
the starting point. This is significantly different than most other rotors.
The edges of the arc cannot be felt when rotating the nozzle turret by hand. There is a light click
sound at the arc edge. If the nozzle turret is rotated past the trip point, another click may be heard.
This is the Memory Arc
®
function activating. No damage has occurred to the rotor. The rotor will click
once again as it is turned back into the area between the arc edges.
The nozzle turret can be rotated by hand at any time in either direction with no damage to the rotor.
The nozzle housing may be rapid advanced by hand to speed the arc setting process.
The arc of the rotor cannot be set to less than 50 degrees. If the 50-degree minimum is reached
during adjustment, a hard stop will be felt on the adjustment screw. To continue moving the arc edge,
move the other edge in the same direction first. Then return and continue moving the first edge. If the
adjustment screw is forced beyond the fixed stop, it will ratchet and click loudly a few times before
damage occurs.
Setting the arc - Method #1:
1. Adjust both arc edges of the rotor larger than desired.
2. To adjust the left arc edge, trip the rotor so that it is rotating counter clockwise.
3. Grip the nozzle housing to halt the rotation at the desired trip point.
4. With the rotor aimed at the desired trip point, slowly turn the left adjustment screw in the clockwise
direction until the torque of the nozzle turret is eliminated. This is a very subtle feel. The click sound
of the trip may also be heard.
5. Verify trip point during normal operation.
6. Repeat the procedure for the right side trip. The rotor must be tripped to rotate clockwise and the
right edge adjustment screw should be turned counter clockwise to reduce the arc until it trips.
Setting the arc - Method #2:
1. Determine where the edges of the arc are by rotating the nozzle turret by hand and listening for the
click sound or observe the trip during operation of the rotor.
2. Use the arc adjustment screws to increase or decrease the arc until the trip is at the desired
location.
Nozzle Installation
(Refer to Figure 2 on fold-out page)
1. Insert the Pull-up Tool into the socket in the top of the rotor and twist 90 degrees. Pull the riser up to
gain access to the nozzle opening and use the hold up tool to support the riser in this extended
position.
2. Loosen the nozzle retainer screw until it no longer obstructs the nozzle opening in the nozzle
housing.
3. Using both thumbs, press the color-coded nozzle firmly into the opening until it is flush with the
nozzle turret.
4. Tighten the nozzle retainer screw. The screw threads must engage the front surface of the nozzle to
ensure proper seating of the nozzle.
5. To remove the nozzle, loosen the nozzle retainer screw and insert a flat-bladed screwdriver into the
Side Pry™ feature on the lower right edge of the nozzle to pry it loose.
Figure 1 Key
A = Part Circle Icon
B = Full/Part Circle Adjustment Slot
C = Left Edge Arc Adjustment Slot
D = Pull-up Tool Slot
E = Nozzle Retainer Screw
F = Full Circle Icon
G = Right Edge Arc Adjustment Slot
Figure 2 Key
X = Nozzle Retainer Screw Slot
Y = Pull-up Tool Slot
Z = Side Pry™ Slot
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für RAINBIRD 5500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von RAINBIRD 5500

RAINBIRD 5500 Bedienungsanleitung - Holländisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info