6. POSITIONING, ASSEMBLY AND INSTALLATION
6.1. Positioning the stove with floor support (Standard supply
for 900 Flat and 901 Ducted, optional for 700,650, 550, 500).
The positioning of the stove is decisive for successful even heating
of the room. Before deciding where to place the stove, the following
must be taken into account:
The stove must be installed on a floor with a sufficient carrying ca-
pacity. If the existing building does not meet this requisite, appropri-
ate measures must be taken (i.e. load distribution plate).
The combustion air cannot be obtained from a garage or from an
area without ventilation or exchange of air, but from a free or exter-
nal space.
The stove must not be installed in a bedroom.
Installation is better in a large and central room in the house to en-
sure maximum circulation of the heat.
Connection to the mains supply is recommended using an earth
socket (if the cable supplied is not long enough to reach the nearest
socket, use an extension flush with the ground).
IMPORTANT GENERAL RULES
1.
It is obligatory to create an initial vertical section of 1.5 mt min. to
guarantee the correct expulsion of smoke.
2.
The pipes must be connected to each other with the male connec-
tor turned downwards to guarantee the smoke and condensation
seal through the gasket.
3.
Horizontal sections must never be more than 3 metres long and
the slope must never be less than 3-5%.
4.
The smoke discharge pipe fitting MUST NOT BE CONNECTED to
a flue used by other generators (stoves, chimneys, boilers..) and
to air extraction systems (HOODS, BREATHER PIPES etc...).
5.
The use of draught adjustment/interruption valves is banned.
Where there is poor or excessive draught in the flue, variations
must be made to the stove’s operating parameters. Contact the
Ecoteck authorised technical assistance centre.
Installation in an existing ue:
This type of installation (see Fig. 9) does not require an insulated
flue, since part of the smoke duct has been mounted inside the home
and part of it inside an already existing flue.
Two 45° pipe fittings are fitted in the middle part of the discharge;
you are advised not to install two 90° elbows since ashes would soon
block the flow of smoke, causing problems for the stove’s draught.
(see Fig. 10).
N.B.: The flue for discharging smoke must be made in observ-
ance of UNI 9615-9731, UNI 10683 - EN1856-1 standards both
with regard to the measurements and the materials used for
construction. Dilapidated flues, built with unsuitable material
(asbestos cement, zinc-plated steel etc..), can jeopardise the
ALESSIA (650)
U .M.
Height mm 580
Width mm 665
Depth mm 676
Weight Kg 120
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,3
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 15
Min.-max. autonomy h 6,5 - 30
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
ERIKA (550)
U .M.
Height mm 563
Width mm 560
Depth mm 664
Weight Kg 105
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,3
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 14
Min.-max. autonomy h 6 - 28
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
FLAT STOVE (900)
U .M.
Height mm 587
Width mm 863,5
Depth mm 650
Weight Kg 150
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,4
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 17
Min.-max. autonomy h 6,8 - 34
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
DUCTED STOVE (901)
U .M.
Height mm 1094 - 1281
Width mm 709
Depth mm 649
Weight Kg 163
Diameter of smoke exhaust duct mm 80
Max. volume of heating m
3
243 (90m
2
)
Min.-max. calorific power Kw/h 2,5 - 11
Min.-max. hourly consumption of pellets Kg/h 0,5 - 2,4
Electrical power absorbed during operation W 110
Supply V - Hz 220 - 50
Tank capacity Kg 17
Min.-max. autonomy h 6,8 - 34
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
500
U .M.
Height mm
459
Width mm
461
Depth mm
481,5
Weight Kg
55
Diameter of smoke exhaust duct mm
80
Max. volume of heating m
3
162 (60 m
2
)
Min.-max. calorific power Kw/h
2,5 - 7,5
Min.-max. hourly consumption of pellets Kg/h
0,5 - 1,6
Electrical power absorbed during operation W
110
Supply V - Hz
220 - 50
Tank capacity Kg
8
Min.-max. autonomy h
5 - 16
The data shown above are indicative and not binding. Ecoteck reserves the right to make any modifications for the purpose of
improving the performances of the product.
The data referring to hourly consumption and autonomy have been calculated considering a pellet yield of: 1 kg= 4,7 Kw/h.
INTERNAL FLUE
Lairtight steel sheeting
Covering plate
YES
45° bend, diam.80
Fig.9
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ravelli 900 Camino Flat wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info