PRECAUTIONS BEFORE START-UP
GENERAL PRECAUTIONS
Remove any objects that may burn from the brazier (manual, various adhesive labels or any polystyrene).
Check that the brazier is positioned correctly and rests properly on the base.
The rst start-up may not be successful as the feed screw is empty and does not always manage to load the brazier
with the required amount of pellets in time to light the ame.
CANCEL THE FAILED IGNITION ALARM BY PRESSING AND HOLDING THE ON/OFF KEY FOR A FEW SECONDS. REMOVE THE
PELLETS LEFT IN THE BRAZIER AND REPEAT THE START-UP.
SETTINGS TO BE CARRIED OUT BEFORE THE INITIAL START-UP
After connecting the power cable to the back of the product, turn the switch at the back to position(I). To turn the stove on or o, press
button 1 on the control panel.
The display on the panel will be ON with a ashing ame. When the ame stops blinking, the stove has reached the operating condition
to “supply power”.
The default target room temperature is set at 20°C. To change this setting, follow the instructions in the adjustments menu; do the same
to set the heating water temperature and the speed of the ventilation fan (if provided). To activate an external thermostat, if present, see
the dedicated paragraph.
POWER SUPPLY
When start-up is complete, the panel will display ON with a constant ame at level 3 . The modulation of the ame for higher or
lower power is then controlled autonomously on the basis of reaching the set temperature.
(see also “OPERATING MODE” - “Set Flame”)