12
12-MENU ENTRIES AND OPERATION
• Use the arrow keys to scroll through and select ‘’Component test’’
• Press “menu” to conrm.
• Use the + - keys to select the test to be carried out.
• Press ‘’menu’’ to conrm and ‘’esc’’ to exit.
k - Chimney sweeper function (for maintenance operators only) -
This function can only be activated when the stove is on and power is supplied, and it forces operation of the boiler at the parameters
P5, with the ventilator (if present) in V5. Any corrections to the loading/smoke ventilation percentage must be read. This state lasts 20
minutes, the countdown is displayed on the panel.
The technician can stop this phase at any moment by quickly pressing the on/o key.
Enable the “Chimney sweeper” function as follows:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to conrm.
• Use the arrow keys to scroll through and select ‘’Chimney sweeper function’’
• Press “menu” to conrm.
• Use the + - keys to select “On” (O by default)
• Press ‘’menu’’ to conrm and ‘’esc’’ to exit.
l - Technical menu
To access the technical menu you must contact the service centre as it requires a password.
Access the “technical menu” as follows:
• Press the “menu” key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu” to conrm.
• Use the arrow keys to scroll through and select ‘’Technical menu’’
• Press “menu” to conrm.
• With the + - keys, select “Product Type”, “Service”, “Counter memories”, “Parameters”.
• Press ‘’menu’’ to conrm and ‘’esc’’ to exit.
INFO MENU
• Product type
• Firmware version
• Software info
• Total hours
• No. of start-ups
• Rpm evacuator
• T. smoke
• Heat exchanger voltage
• Feed screw loading
• Flame