ColourT emp digital thermometer
Instruction manual // item no .:98030
Congratulations on pur chasing your new reer thermomet er . Please read the
instruction manual before using the devic e for the first time in order to be
able to make use of all the advantages it off ers. Please keep the instruction
manual in a safe place for futur e referenc e.
Legend
The following symbols are used in the user manual, on the packaging and
on the type plate of the devic e and the acce ssory:
Caution
Permitted stor age and transport tempera ture and air humidity
Permitted operating t emperature and air humidity
Manufacturer
Observe the user manual
Application part type BF
Disposal according t o the Wast e Electrical and Electronic
Equipment EC directive
Batch designation
IP 22
Protection against entry of solid f oreign bodies with a
diameter of >12.5 mm. Prot ection against dripping water
with a 15° incline.
The CE marking certifies c onformity with the basic require-
ments of the 93/42/EEC guidelines for medical products .
Scope of deliv ery
• Thermometer
• Operation manual
• 1 x 3 V CR2032 battery
Safety instructions
• The thermometer is intended ex clusively to measur e human body
temperature .
• The ColourT emp thermometer is designed to only be used at the
measurement points on the human body that are specified in the
user manual.
• Check the unit for visible damage before e ach use. If you detect any
damage, do not use the unit.
• The thermometer is intended for priv ate use.
• Children should not use the devic e without adult supervision. Medical
products are not to ys.
• Children under 12 should not measure their o wn body temperature
without supervision.
• This thermometer contains small parts that can be sw al lowed or
present a choking hazard for childr en. Always keep the thermometer
out of the reach of childr en!
• Do not open the device , with the exc eption of the cov er on the
battery compartment. No modifications may be made to the devic e.
If a device does not w ork correctly , please c ontact your dealer .
• Keep the battery out of the r each of children as there is a risk of
swallowing.
• The thermometer contains sensitiv e electronic components. Pro tect it
against impacts, bending, high temperatures or dir ect sunlight.
• The minimum measurement time until the sound signal must alw ays
be observed.
• This thermometer is equipped with a flexible measurement tip and
provides more c omfort and safety during measur ement, especially for
small children as well as sleeping persons and persons with limited
consciousness. The tip should no t be bent further than 90°!
• Operation in the vicinity of strong electr omagnetic fields, e.g. next t o
a mobile phone, may lead t o malfunctions.
• In the event of unusual temper ature readings , immediately contact
your GP .
• Please note that portable and mobile HF c ommunication equipment
can affect this devic e. Y ou can obtain more detailed information a t the
customer service addr ess specified, or at the end of the user manual.
Before firs t use
To s witch the device on, pr ess the -button. Y ou wil l hear a short signal
tone. Then, the thermometer carries out a self -test. The display indicates all
the segments (Fig. 1) on screen, lit up in green. The last measur ed value is
then displayed for appro ximately 2 seconds. The thermome ter is ready for
measurement if the display sho ws ‘Lo’ and the ‘°C’ or ‘°F’ symbol blink s.
The current tempera ture is displayed c ontinuously during the measurement,
and the ‘°C’ symbol blinks for the entire me asuring duration. The measur ement
will be completed after about 10 sec onds. The measurement ends as soon
as temperature s tability is achieved. An acoustic signal is pr oduced (3 x 3
slow beeps), the ‘°C’ symbol stops blinking and the me asured temperatur e
is indicated. At temper atures under 37.6 °C (99.7 °F), the display will be
illuminated green.
To pr olong the battery service lif e, switch the thermomet er off after use by
pressing and rele asing the -button. Otherwise, the thermometer will switch
off automatically 10 minutes later , producing a beeping sound.
Y ou can switch between displa ying the temperature in °C or °F . To do this,
press and hold the
-button for 2 seconds until ‘L o’ is displayed. Shortly
before °C starts blinking, press the -button again, until you get the de sired
measurement unit.
LCD-Display ON / OFF Sensor
Fig. 1
Fev er warning
If a body temperature o f more than 37.6 °C (99.7 °F) is detected, a fe ver
warning alarm signal is produc ed (3 x 4 quick beeps), and a display lights
up in red. If temperatur es outside the measuring range ar e detected, the
display indicates ‘Lo ’ for temperatures under 32 °C (90 °F) and ‘Hi’ for ov er
43.9 °C (111 °F).
Last measur ed value display
The last measured v alue is always display ed during the start -up of the
thermometer , for about 2 seconds indicated
Measured v alue dispersion
Temper atures can v ary depending on measurement points. This is normal and
is caused by uneven distribution of t emperature in the human body . Thus ,
for example, y ou can have a temper ature of 36.6 °C if measured r ectally ,
36.1 °C if measured orally , and 35.6 °C if measured axillarily . With multiple
measurements, take 3-minut e breaks betw een them.
Measurement poin ts
Anus (rectal)
This is the most reliable method. It is particularly suited f or infants and small
children. The thermometer tip is carefully inserted 2 - 3 cm into the anus.
Measuring duration: appr ox. 10 seconds
In the mouth cavity (oral)
Small temperature fluctuations from me asurement to measurement ar e normal
in the mouth cavity . They are caused b y uneven temper ature distribution in
the mouth. Insert the thermometer in one of the two he at pockets under the
tongue, to the left and right o f its root. The temperature sensor must hav e
good contact with the tissue. Close the mouth be fore measuring for about
1 minute, bre athing calmly through the nose. Then insert the measuring tip
of the thermometer in the heat pocke t and close the mouth. This way , the
measurement result will not be aff ected by the air you bre athe. Measuring
duration in the mouth cavity: appro ximately 30 seconds
In the armpit (axillar)
From a medical point of view , this measur ement method produces r esults that
are too imprecise. It is thus no t suitable for taking accur ate measurements.
The reason is that c ontact between the tempera ture sensor and the armpit
is much worse than contact in the case of or al or rectal measurements.
This results in there being no temper ature balance betw een the tempera-
ture sensor and the tissue, which is nec essary for a reliable me asurement.
Measurement
methods
Recommended
measuring duration
Aver age deviation
for the rectal method
in the anus until the sound signal
–
in the mouth cavity until the sound signal - 0,4 °C to - 1,5 °C
in the armpit
min. 5 Min.
- 0,7 °C to - 2,0 °C
Changing the batteries
If the display shows an symbol, the battery is empty and require s a
replacement. Replace the depleted ba ttery with one of the same type. T ake
the following steps to do this:
Open the battery compartment using a c oin. Remove the empty batt ery
and insert a new battery (CR 2032). Please take car e to ensure the corr ect
installation position. The ‘+’ symbol on the battery must point upw ards. Then
screw the battery c ompartment lid back onto the housing. Y ou can find the
appropriate batterie s in watch or electric applianc e stores.
Used batteries should not be disposed of toge ther with normal household
waste . Y ou are legally required to properly dispose of ba tteries. Dispose of these
at your electric goods stor e or your local recyclable material c ol lection station.
B
a
t
t
e
r
y
C
R
2
0
3
2
B
a
t
t
e
r
y
C
R
2
0
3
2
B
a
t
t
e
r
y
C
R
2
0
3
2
O
P
E
N
C
L
O
S
E
Battery co ver
CR2032 Battery
Notes on handling batterie s
• If a battery cell leak s out onto your skin or eye s, wash the affect ed
area with w ater and seek medical help .
• If a battery has leaked, put safety glo ves on and clean the batt ery
compartment with a dry cloth.
• Protect batterie s from exc ess heat
Risk of swallo wing!
Small children can swallow batt eries and choke on them. Keep batteries
away fr om small children!
Metrological c ontrol
As a rule, checking the thermometer’ s precision is not required. F or devices
used in Germany for medical practic e, the Medical Products Opera tor
Ordinance of 29 June 1998 (in the v ersion announced on 21 August 2002,
last amended by Article 4 of the law of 29 July 2009) r equires metrological
control aft er 2 years. Gauging offic es provide paid metrological inspections .
Cleaning and disinfection
• Disinfect the thermometer and the measuring tip with alc ohol
(75% isopropyl alcohol). All pharmacies sell alc ohol cleaning pads
from various manuf acturers, with which you can c ompletely wipe
the device.
• Wipe the thermometer dry with a soft cloth.
• DO NOT BOIL OR W ASH IN DISHWASHER. This wil l negatively affect the
functional capacity of the thermometer and will void the warr anty .
• Do not clean the devic e with chemical thinners and solvents.
• Store the thermometer in a dry , dust -free, clean plac e awa y from
direct sunlight.
Microbial c ontamination
Because complete disinf ection is often not possible in household use, it is
highly recommended to pr ovide an individual thermometer to e ach patient.
Disposal instructions
Batteries must be disposed of appropriat ely . Appropriate bins for
battery disposal are av ailable for this purpose at retail shops that
sell batteries, and at c ommunal collection points.
After the end of its service lif e, please dispose of the devic e correctly through
a community collection point for w aste electrical products.
Legal basis for marketing the de vice in the EU:
The manufacturer w as certified acc ording to the guidelines of 93/42/EEC
for medical products. This devic e complies with the EN60601 - 1- 2 Europe an
standard on electromagnetic c ompatibility and meets the requirements
of EN 12470 - 3.
W arranty
Please retain your r eceipt, the instruction manual and product number .
Warr anty claims or claims under other promises of guarant ee must be
proces sed by the dealer . The statutory warr anty period is 2 years from the
date of purchase. Liability f or defects does not include damage caused by
inappropriate handling. The purchase rec eipt and a description of the defect
are required for w arranty claims.
The technical specification, instructions and charact eristics of the product
described herein have been c ompiled to the best of our knowledge and
belief , and are correct at the time of printing. Any instructions pro vided
by reer should be corr ect and reliable. Neverthele ss, reer does not ac cept
liability for potential errors in this document and r eserves the right to make
changes to the product design and/or specifications without prior notic e.
T echnical data
Type: ColourT emp digital thermometer
Item number:
98030
Measuring range: 32,0°C to 43,9°C (90°F~111°F)
Measuring accur acy: ±0.1 °C (±0.2 °F) in water bath, in the range
35.0~42.0 °C (95 °F~107.6 °F)
±0.2 °C (±0.4 °F) at an ambient temperatur e
of 22 °C (71.6 °F)
Measuring units: Centigrade and F ahrenheit (° F)
Fever w arning:
acoustic and optical w arning >37,6°C (99,7 °F)
Display: LCD display
Battery type: 1 x CR2032 (included)
Net weight:
27g
Ambient temperature
Operating
+10 °C to +31 °C at 30—85% relative air
humidity
Storage/T ransport
+0 °C to +50 °C at 25—90% relative air
humidity
WellKang Ltd, Suit e B, 29 Harley Str eet LONDON W1G 9QR, England, United
Kingdom
Cotr onic Technology L td
Floor 4~6,Block 7, west of ZhouShi Road, XiXiang S treet, Bao An Zone,
ShenZhen, GuangDong, China
Sales and customer servic e:
reer GmbH • Muehlstr . 41 • 71229 Leonberg • Germany • www .reer .de