5.10 Schéma électrique
PLA-300024917-03
SCHEMA DE PRINCIPE - STROMLAUFPLAN - PRINCIPLE DIAGRAM - AGC - GSCR - CALORA TOWER GAS DE -
CALORA TOWER GAS Si BE
1
2
3
4
5
6
RL_VI
CH OHW
X11
RL_BO_PUMP RL_SAN_PUMP
PCU-192
S ECS
12
X20
C
S.DHW
+-
21
F 6,3AT
1
2
3
4
5
6
X2
Boiler Lighting
SCU D4
SONDE
ECS
+
-
T.A
S EXT
RLBLOT
X12
23
X4
San Pump
32
VG
15
X21
X6
43
X22
2
213
SI
X5
234 5
124 5
VN
X91
X9
1
2
1
0
X117
H.L
10 11 23
X8
12
X41
BO Pump
12
X116
123 4
235 4
PSU X11
X111
31
31
Pressure
sensor
2
896
C
1
2
Return
sensor
7
2
C
1
2
X112
X114X115
X10
SPL1
1
2
1
Flow
sensor
11
123
Inv. valve X121
X121
12
3
X7
31
X2
4132
X3
3 2
X1
LN
230V / 50 HZ
J1
21
3
J10
C
C
12
12
SONDE
SYST
J5
INTERFACE HOMME - MACHINE
HMI
POMPE CHAUDIERE
ALIMENTATION
230V/50HZ
FUSIBLE 6.3A TEMPORISE
F6.3AT
BO PUMP
ZG
INTERRUPTEUR GENERAL
POMPE SANITAIRE
SAN PUMP
SONDE EXTERIEURE
SONDE EXT
SONDE EAU CHAUDE SANITAIRE
SONDE ECS
TA
TITANE ACTIVE SYSTEME
PWM BO PUMP
X116
VANNE D'INVERSION
X121
THERMOSTAT LIMITEUR HAUT (H.L)
X117
TEMPERATURE DEPART
X115
TEMPERATURE RETOUR
X114
CONNECTEUR BUS SU
X111
SONDE DE DEPART
SONDE DEP
SONDE EAU FROIDE SANITAIRE
SONDE DHW in
UNITE DE CONTRÔLE PRIMAIRE
PCU
NEUTRE
N
PHASE
CONNECTEUR CIRCUIT IMPRIME SCU/PCU
J-/X1...X20
X21
VANNE GAZ
MANOMETRE EAU
L
X112
VENTILATEUR
X91
BO PUMP 230V
X41
TRANSFORMATEUR D'ALLUMAGE
X22
UMSCHALVENTIL
HOCH TEMPERATURWÄCHTER (H.L)
VORLAUFTEMPERATUR
RÜCKLAUFTEMPERATUR
BUS SU STECKER
VORLAUFFÜHLER
SANITÄR KALTWASSERFÜHLER
PRIMÄRE STEUEREINHEIT
NULLEITER
PHASE
LEITERPLATTE STECKER SCU / PCU
SNITTSTELLE MENCH MACHINE
KESSEL PUMPE
NETZANSCHLUSS
GASVENTIL
SICHERUNG 6.3A TRAEGE
WASSER MANOMETER
GEBLÄSE
BO PUMP 230V
ZÜNDTRAFO
HAUPTSCHALTER
SANITÄR PUMP
AUSSENFÜHLER
WARMWASSERFÜHLER
TITANE ACTIVE SYSTEM
PWM BO PUMP
SHIFTING VALVE
X121
HIGH LIMITER THERMOSTAT (H.L)
X117
FLOW TEMPERATURE
X115
RETURN TEMPERATURE
X114
BUS SU CONNECTOR
X111
FLOW SENSOR
SONDE DEP
SANITARY COLD WATER SENSOR
SONDE DHW in
PRIMARY CONTROL UNIT
PCU
NEUTRAL
N
PHASE
PRINTED CIRCUIT BOARD PLUG SCU/PCU
J-/X1...X20
HUMAN MACHINE INTERFACE
HMI
BOILER PUMP
MAIN SUPPLY
230V/50HZ
X21
GAS VALVE
FUSE 6.3A DELAYED
F6.3AT
PRESSURE SENSOR
BO PUMP
L
X112
FAN
X91
BO PUMP 230V
X41
IGNITION TRANSFORMER
X22
ZG
MAIN SWITCH
SAN PUMP
SANITARY PUMP
OUTSIDE SENSOR
SONDE EXT
DOMESTIC HOT WATER SENSOR
SONDE ECS
TA
TITANE ACTIVE SYSTEM
PWM BO PUMP
X116
OMKEERKLEP
HOOG BEGRENZINGS THERMOSTAT (H.L)
AANVOER TEMPERATUUR
RETOURTEMPERATUUR
BUS SU STEKKER
AAN VOELER
SANITAIR KOUD WATER SENSOR
EENHEID PRIMARE CONTRÔLE
NULLEIDER
FASE
AANSLUITKLEM SCU/PCU
DE INTERFACE MAN MACHINE
KETTEL PUMP
VOEDING
GASKLEP ONTSTEKING
SMELTLOOD 6.3A
WATER MANOMETER
VENTILATOR
BO PUMP 230V
ONTSTEKINGSTRANSFO
ALGEMENE SCHAKELAAR
SANITAIRE POMP
BUITEN VOELER
SANITAIR WARM WATER SENSORS
TITANE ACTIVE SYSTEM
PWM BO PUMP
ENTREE
0-10 V
EINTRITT INLET
0-10 V
INGANGSAN
ACCELERATEUR CIRCUIT A
A
KESSELKREISPUMPE KREIS A HEATING PUMP CIRCUIT A
A
VERWARMINGSPOMP KRING A
POMPE DE CHARGE SPEICHERLADEPUMPE LOAD PUMP VUL POMP
UNIQUEMENT AVEC BALLON H.L
NUR MIT H.L SPEICHER ONLY WITH HIGH LOAD TANK ALLEEN MET H.L BOILER
ZG
43
ZG
21
RELAIS TELEPHONIQUE FERNSPRECHRELAIS
TELEPHONE RELAY TELEFONISCH RELAIS
SONDE D'AMBIANCE (A)
SONDE AMB A
RAUMFÛHLER (A) ROOM SENSER (A)
SONDE AMB A
RUIMTECIRCUIT (A)
UNITE DE CONTRÔLE SECONDAIRE
SCU
SEKUNDÄRE STEUEREINHEIT SECONDARY CONTROL UNIT
SCU
EENHEID ONDERGESCHIKTE CONTRÔLE
HMI
V3V
VANNE 3 VOIES DREIWEGEMISCHER
V3V
THREE WAY VALVE 3 WEGMENKRAAN
L NNL N
A
B
V3V
N
B
L21
+TS
2
J7
SONDE
EXT
12
C
SONDE
DEP C
12
C
SONDE
DEP B
12
C
SONDE
AMB A
12
SONDE
AMB B
12
SONDE
AMB C
12
1234
31
J6
1
J7
0 -10 V
12
RL-V3VALIM
RL-V3VOF
RL-PB
RL-PA RL-ECS T
CALORA TOWER GAS 15Si BE - 25Si BE - 35Si BE 5. Installation
15/03/2016 - 7605048-001-07 65
67

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Remeha Calora Tower Gas 15Si wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Remeha Calora Tower Gas 15Si

Remeha Calora Tower Gas 15Si Bedienungsanleitung - Deutsch - 52 seiten

Remeha Calora Tower Gas 15Si Bedienungsanleitung - Holländisch - 44 seiten

Remeha Calora Tower Gas 15Si Installationsanweisung - Holländisch - 148 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info