Allow the system to cool down for 5 minutes before attempting to change attachments.
Turn the Power Switch OFF and unplug the Power Cord from the electrical outlet.
Hold the attachment with one hand while pressing both Attachment Release Buttons with the other hand and pull
gently (Fig. 10).
Gently push the other attachment back into the Hand Piece making sure both side tabs click into place.
NOTE: the longer tab (with gold circuits) must be on top to properly t.
Store the unused attachment in a safe location (such as in the packaging) taking care not to damage the Flash
Window and other components.
The i-LIGHT is equipped with two operating modes: Single Flash Mode and Multi-Flash Mode. Your i-LIGHT device
will automatically be set to Single Flash Mode each time the device is powered ON.
Single Flash Mode: The i-LIGHT will ash each time the Flash Button is pressed. This mode is ideal for precision treat-
ments of the face and small areas.
Multi-Flash Mode: The i-LIGHT device will ash when the Flash Button is pressed and will continue to ash every 3
seconds when the skin contact sensors are fully engaged. The Multi-Flash mode allows you to quickly treat large
areas by simply gliding the hand piece over the skin after each ash.
How to treat:
Place the Flash Window rmly against the skin - ensure the Skin Contact Sensors are fully engaged.
NOTE: When the Skin Contact Sensors are fully engaged you will hear a chirp’ and the Bulb Status Indicator Display
will illuminate green.
Press the ash button to deliver a ash. You should expect to see a bright ash of light (similar to a camera ash) and
you should feel a mild sensation of warmth.
Move to the next area and treat in a grid like pattern to ensure full coverage of the treatment area.
For Single-Flash Mode, press the Flash Button each time you move to the next area.
For Multi-Flash Mode, keep your nger on the Flash Button to keep it depressed and glide to the next area being
sure to keep the Skin Contact Sensors fully engaged. The next ash will be delivered automatically after 3 seconds.
NOTE: During Multi-Flash Mode if you let go of the Flash Button or lose skin contact, simply resume treatment by
repeating the above steps.
Facial Treatment (female use only)
Facial hair can be very dierent to body hair and the skin on the face tends to be sensitive and more likely to be
exposed to the suns UV rays; therefore treating unwanted facial hair is dierent to treating the body – please be sure
to read the Warnings and Safety Precautions carefully before beginning a facial treatment.
IMPORTANT: The Facial Attachment has been specially designed to treat the unique characteristics of female facial
hair. DO NOT use the Body Attachment on the face. See section Changing Attachments’ for more information.
The Facial Attachment is only intended for use on female facial hair below the cheekbone (Fig. 2).
DO NOT use on male beards or facial hair as the results may be permanent or uneven which may produce changes in
facial hair characteristics which may not be desirable.
TREATMENT TIPS
Body Treatment
For best results, avoid overlapping ashes. This helps prevent exposure to more energy than is necessary to suppress
hair growth. It also ensures that you get the maximum use of the Bulb.
For the most eective results, always use the highest intensity operating mode that does not cause discomfort on
the skin. The level you use should feel warm on your skin, but should never cause discomfort.
You may notice that bony areas, such as elbows, shins and ankles, are more sensitive during treatment. This is normal
and should not be cause for alarm. To avoid this sensitivity, try stretching the skin away from the bony area during
treatment.
Facial Treatment
Test on a Patch of Skin – since facial skin tends to be more sensitive, make sure you test on a small patch before
proceeding. See section Test the i-LIGHT on your skin for more details.
Use a Mirror to Guide your Treatments – using a mirror for a good view of the area to be treated and to help ensure
you avoid treating the lips or any other dark spots. If the reected light is unpleasant, you may want to close your
eyes before each ash.
GB
DE
NL
FR
ES
IT
DK
SE
FI
PT
SK
CZ
PL
HU
RU
TR
RO
GR
SI
AE
HR
UA
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Remington IPL6780 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info