719938
9
Zoom out
Zoom in
Vorherige Seite
1/200
Nächste Seite
9
ENGLISH
Express Mode F
Express Mode provides the user with a time friendly option for treatments. You may treat larger areas with this mode at
a faster rate, but it may be less eective and will take a few more treatments to see the desired results.
NOTE: Whenever the device is turned on, it automatically defaults to Power Mode (Full Power).
If you wish to select an alternative mode, press and hold the desired button to illuminate it.
Once you have decided and chosen which operating mode is right for you, put the treatment window rmly against
your skin.
The device is now ready to trigger the rst ash. To deselect the Sensitive or Express Mode, simply press the
selected button again and the unit will revert back to Power Mode with only the Flash Button illuminated.
TREATMENT
CHANGING ATTACHMENTS
Your i-LIGHT comes with two separate Treatment Caps.
The Body Treatment Cap is for use on larger areas such as body hair.
The Precision Treatment Cap is intended for use on smaller areas such as female facial hair, underarms and bikini
area.
To change attachments:
WARNING: Always ensure the unit is OFF and the power cord is disconnected before removing the Treatment Cap.
Allow the system to cool down for 5 minutes before attempting to change the Treatment Cap
1. Turn the Power Switch OFF and unplug the Power Cord from the electrical outlet.
2. Hold the device with one hand while gently pulling the Treatment Cap with the other (Fig. 13).
NOTE: Treatment Caps are magnetically held onto the device and should pull o easily.
TIP: Store the unused Treatment Cap in a safe location taking care not to damage the ash window and other
components.
3. Gently push the other Treatment Cap back onto the device making sure it clicks into place.
How to treat:
1. Place the Flash Window rmly against the skin - ensure the Skin Contact Sensors are fully engaged. If the
Skin Contact Sensors are in full contact, the ash button on the device will pulse white and the LEDs on
the side of the hand piece will light up indicating the device is ready to ash.
NOTE: If the Skin Contact Sensors are NOT in full contact with the skin, the device will not operate if you press the
Flash Button and it will beep. Double check that the Skin Contact Sensors are in full contact with the skin.
2. Press the ash button to deliver a ash. You should expect to see a bright ash of light (similar to a camera ash)
and you should feel a mild sensation of warmth.
3. Move to the next area and treat in a grid like pattern to ensure full coverage of the treatment area.
For single-ash mode, press the ash button each time you move to the next area.
For multi-ash mode, keep your nger on the ash button to keep it depressed and glide to the next area being
sure to keep the Skin Contact Sensors fully engaged. The next ash will be delivered automatically after 3 seconds
(in Full Power Mode).
During multi-ash mode if you let go of the ash button or lose skin contact, simply resume treatment by
repeating the above steps.
Facial Treatment (female use only)
Facial hair can be very dierent to body hair and the skin on the face tends to be sensitive and more likely to be
exposed to the sun’s rays; therefore treating unwanted facial hair is dierent to treating the body – please be sure to
read the Warnings and Safety Precautions carefully before beginning a facial treatment.
IMPORTANT: The Precision Treatment Cap has been specially designed to treat the unique characteristics of female
facial hair. We would therefore advise against using the Body Treatment Cap on the face as this has been designed to
treat large areas below the neck. See section ‘Changing Attachments’ for more information.
The Precision Treatment Cap is intended for use on female facial hair on the cheek, sideburn, chin, neck area and above
the lips (Fig. 2). It can also be used on other smaller areas such as the underarms and bikini area.
DO NOT use on male beards or facial hair as the results may be permanent or uneven which may produce changes in
facial characteristics which may not be desirable.
GB
DE
NL
FR
ES
IT
DK
SE
FI
PT
SK
CZ
PL
HU
RU
TR
RO
GR
SI
BG
AE
HR
UA
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Remington IPL8500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info