Electrical wiring
The units are operated with
230 V 50 Hz alternating current
The electrical
connection is made
using a built-in
mains cable with
earthed safety plug
Extensions to the connection
cable may only be carried out
by authorised electricians,
subject to the length of
the cable, connected load
of the unit and taking into
consideration how the unit is
used at its location
s
s
s
Control panel
All rotary knobs and the
corresponding indicator lights are
located on the control panel.
“Container full” display
“Hot gas defrosting” display
“Timer activated” display
Display for temperature
indication and timer setting
Display to show and adjust the
relative humidity
“Power ON/OFF” key
Key for fan speed
Key for “1 to 24 hrs” timer
(in 1 hour steps)
Key to adjust the hygrostat
from 30 to 90 % RH in 5 %
steps
Changeover button to display
in °C or °F
Switching the units on
Connect the unit's power plug
to a properly installed mains
socket
Press the power key []
Use the [] key to select the
(min/max) air volume
The electrical connection to the units
must be made at feed-points with
residual current devices in accordance
with VDE 0100, Section 704.
When installing the units in
extremely damp environments such
as laundry rooms, showers etc., the
unit must secured with a residual
current device provided by the
customer in accordance with the
regulations.
NOTE
In room temperatures
below
10 °C
and relative
humidity below
40 %
,
economical use of the unit can
no longer be guaranteed.
NOTE
When the units are connected
to the power supply, they beep
quickly and the displays flash
once.
NOTE
Adjusting the humidity level
The unit’s dehumidification power
is entirely dependent on the
conditions inside the room, the
room temperature, the relative
humidity and observance of the
notes in the “Set-up” chapter.
The higher the room temperature
and relative air humidity, the
higher the dehumidification power.
A relative humidity of around
45 to 60 % is recommended for
living rooms.
However, the air humidity
should not exceed 40 to 45 % in
warehouses, archives, etc.
Unit initial settings:
Fan speed = min.
Humidity = 60 % RH
Use the [] buttons to select
the required humidity (% RH)
The set value is shown on
the display [] for around
10 seconds
The humidity level can be
adjusted in 5 % steps
from 30 - 90 % RH
In normal operating mode, the
display [] shows the current
humidity level in % RH
The display [] shows the
current room temperature
in °C or °F
The display is changed over
using the [] key
All cable extensions must only
be used in fully un-reeled or
reeled off condition.
CAUTION
!
The units are only permitted
to be operated with the outlet
grill clear in order to prevent
overheating.
CAUTION
!
NOTE
At a humidity of < 30 %,
the “LO” indicator is shown
and, at > 90 %, the “HI” is
shown on the display [
]
.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO ETF460 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO ETF460

REMKO ETF460 Bedienungsanleitung - Deutsch - 20 seiten

REMKO ETF460 Bedienungsanleitung - Holländisch - 20 seiten

REMKO ETF460 Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info