587986
49
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
Spare parts list
When ordering spare parts, please indicate both the reference number and the machine number (see model plate)!
No. Designation
KWG 950
(P, SP)
KWG 950
(P, SP) SLN
KWG 1100
(P, SP)
KWG 1100
(P, SP) SLN
KWG 1300
(P, SP)
KWG (SLN) as of serial number 1033...05... 1033...35... 1033...06... 1033...36... 1033...07...
KWG P (SLN) as of serial number 1033...15... 1033...45... 1033...16... 1033...46... 1033...17...
KWG SP (SLN) as of serial number 1033...25... 1033...55... 1033...26... 1033...56... 1033...27...
1 Control panel, compressor unit 1120700 1120700 1120700 1120700 1120700
2 Fan panel 1120701 1120701 1120701 1120701 1120701
3 Roof panel 1120705 1120705 1120705 1120705 1120705
4 Side panel 1120706 1120706 1120706 1120706 1120706
5 Side panel 1120709 1120709 1120709 1120709 1120709
6 Transport bracket 1120711 1120711 1120711 1120711 1120711
7 Air-cooled condenser, right 1120712 1120713 1120713 1120713 1120725
8 Air-cooled condenser, left 1120726 1120727 1120727 1120740 1120740
9 Condenser fan 1120749 1120750 1120749 1120750 1120749
10 Evaporator 82-100 1120754 1120754 1120755 1120755 1120757
11 Compressor SCP 400 2 x 1120763 2 x 1120763 - - 2 x 1120763
11 Compressor SCP 510 1 x 1120764 1 x 1120764 1120764 1120764 2 x 1120764
12 Circulation pump (P, SP) 370-1 1120767 1120767 1120767 1120767 -
12 Circulation pump (P, SP) 370-2 - - - - 1120768
13 Diaphragm expansion vessel 8 litres (P, SP) 1120771 1120771 1120771 1120771 1120771
14 Safety valve, medium circuit, 6bar (P, SP) 1120773 1120773 1120773 1120773 1120773
15 Medium storage tank (SP) 1120775 1120775 1120775 1120775 1120775
16 Pressure gauge 1120776 1120776 1120776 1120776 1120776
17 Medium circuit pressure switch (SP) 1120781 1120781 1120781 1120781 1120781
16 Controller cover 1120777 1120777 1120777 1120777 1120777
17 Victaulic coupling with rubber seal 1120692 1120692 1120692 1120692 1120694
18 Victaulic nipple 100mm 1120693 1120693 1120693 1120693 1120695
Spare parts without illustration
High pressure monitor 1120782 1120782 1120782 1120782 1120782
Low pressure monitor 1120783 1120783 1120783 1120783 1120783
Complete expansion valve 1120785 1120785 - - 1120785
Complete expansion valve 1120787 1120787
Pressure transducer, cooling circuit 1120796 1120796 1120796 1120796 1120796
Safety valve, cooling circuit 44bar 1120797 1120797 1120797 1120797 1120797
Differential pressure switch SFS-90 - - - - 1120803
Differential pressure switch SFS-105 1120802 1120802 1120802 1120802 -
Phase sequence relay 1120804 1120804 1120804 1120804 1120804
Controller IPS 408D-11010 1120805 1120805 1120805 1120805 1120805
Controller IPS 408, programmed 1120847 1120848 1120849 1120850 1120851
Controller expansion IPEX60 - - - - 1120852
Transformer 400/230 1120853 1120853 1120853 1120853 1120853
Transformer 230/24 30VA 1120854 1120854 1120854 1120854 1120854
Transformer 230/24 10VA 1120855 1120855 1120855 1120855 1120855
Medium inlet/outlet sensor, environment 1120856 1120856 1120856 1120856 1120856
Compressor contactor 1120860 1120860 1120860 1120860 1120860
Circulation pump contactor (P, SP) 1120861 1120861 1120861 1120861 1120861
Condenser fan contactor 1120861 1120861 1120861 1120861 1120861
Fan control, winter fan control 1120863 1120863 1120863 1120863 1120863
Crankcase heater 1106368 1106368 1106368 1106368 1106368
49
49

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO KWG1100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO KWG1100

REMKO KWG1100 Bedienungsanleitung - Deutsch - 60 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info