587982
38
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
The emission of refrigerant
contributes to climate
change. In case of an
escape, refrigerant with a
lower greenhouse potential
contributes less to global
warming as those with high
greenhouse potential.
This unit contains refrigerant
with a greenhouse potential
of 1975. An escape of 1 kg of
this refrigerant thus has a 1975
times
greater effect on global warm-
ing than 1 kg CO
2
over 100
years. Do not work on the
cooling circuit or dismantle the
unit – always involve specialist
personnel for these tasks.
NOTE
Servicing and repair must be
performed only by specially
trained specialist personnel
and documented accordingly.
NOTE
Servicing and repair
Cooling circuit
Repairs to the cooling circuit must
be documented in the operating
instructions. The following
measures must be observed:
Environmentally sound collec-
tion and disposal of refrigerant
and defective components
Proper and constantly per-
formed repairs with the intend-
ed connection materials and
original spare parts
Long-lasting seal tightness
check according to the
maximum pressure occurring
Long-lasting and proper evacu-
ation and drying of the cooling
circuit
Proper filling with varietally
pure refrigerant and the
corresponding amount
according to the operating
instructions / type plate
Function check of the safety
components
Medium circuit
Repairs to the medium circuit are
to be performed and documented
according to the current regula-
tions and/or regional guidelines.
The following measures must be
observed:
Environmentally sound
collection and disposal of
operating media and defective
components
Proper and constantly per-
formed repairs with the intend-
ed connection materials and
original spare parts
Long-lasting seal tightness
check according to the maxi-
mum pressure occurring
Function check of the safety
components
Proper filling with varietally
pure operating medium
Electrical components
Repairs to the electrical compo-
nents are to be performed and
documented according to the
current regulations and/or regional
guidelines. The following measures
must be observed:
Environmentally sound disposal
of defective components
Proper and constantly per-
formed repairs with original
spare parts
Inspection of the unit and / or
system according to the cur-
rently valid regulations and
guidelines, e.g, protection
against direct contact, damage
to / defects in components,
changes in factory-provided
components, etc.
Testing of the unit and /
or system according to the
currently valid regulations and
guidelines, e.g., equipment for
protection against electrical
shocks / overvoltage / incorrect
rotating field, overcurrent
protection equipment,
display and fault message
notification equipment, locking
mechanisms, etc.
Measurement and assessment
of the unit and / or system
according to the currently valid
regulations and guidelines,
e.g., insulation resistance, loop
impedance, residual current
operated protective devices,
low-impedance connection
of the protective earthing
conductor, earthing resistance,
integration into lightning
protection measures, etc.
When handling refrigerant,
wear corresponding protective
clothing.
!
ATTENTION
The refrigerant used may be
filled only in liquid form.
!
ATTENTION
All service/repairs must take
place when the system is de-
energised.
!
ATTENTION
REMKO KWG
38
38

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO KWG600 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO KWG600

REMKO KWG600 Bedienungsanleitung - Deutsch - 60 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info