587594
14
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
14
Assembly Instructions for
Service Personnel
Important instructions prior to installation
Ensure that the contents of the package are com-
plete and that the units have no visible damage re-
sulting from transport. Any problems must be com-
municated directly to your contract partner and the
shipping company.
Subsequent complaints will not be acknowledged.
Place the unit in its original packaging as close as
possible to the location where it will be assembled to
prevent damage from transport.
Prior to installation, check that the electrical connec-
tion values and the data on the type plate are
consistent.
Do not install the unit in the direct vicinity of objects
that emit intense heat.
Lights, etc.
Select a location to set up the unit where air can flow
freely in and out of the device.
Observe minimum distance.
Only use the swivel nuts supplied for the refrigerant
pipes. Other components can damage the thread.
Remove the protective caps of the unit connections
just before connecting the refrigerant pipes.
Make sure that the maximum length of 10 or 15 me-
ters for the refrigerant pipes is not exceeded and the
difference in height to the unit is not more than 5 or
8 meters.
The refrigerant pipes may not be bent or pressed.
Make sure that all refrigerant pipes including all con-
nectors and valves are insulated against heat and
sealed against diffusion.
Only add additional refrigerant to the system if the
length of the refrigerant pipes exceeds 5 meters.
See the “Adding refrigerant” section for the addi-
tional refrigerant amounts.
The condensation pipe must be placed at an incline
of at least 2%.
If this pipe is connected to a sewage pipe, an odour
seal must be installed the upper edge of which
may not extend beyond the lower edge of the indoor
unit.
All electrical connections must meet the relevant re-
quirements. The power supply is only connected to
the outdoor unit.
The control line to the indoor units should be laid at the
same time as the refrigerant pipes.
Make sure that the electrical lines have been prop-
erly attached in the electrical terminals.
The indoor unit and outdoor unit of the REMKO air-
conditioner have been adjusted to one another from
a technical standpoint.
The guarantee becomes null and void if third-party
components are used.
Remember that when installing and maintaining air
conditioners, high-pressure refrigerant pipes and
electrical current can pose hazards.
During unit operation, some components in the cool-
ing cycle can reach temperatures of more than
70°C.
Be especially careful when covers are removed.
Preventable installation mistakes
Make absolutely sure to follow the instructions below
when installing the indoor unit:
Place the pipes between the indoor unit and the out-
door unit and keep the length of the refrigerate pipes
as short as possible.
The shut-off valve of the refrigerant pipes may only
be opened once installation is complete.
Always secure electrical lines properly in the electri-
cal terminals.
Not doing so could cause a fire.
Seal open refrigerant pipes with suitable caps and/or
adhesives to prevent moisture penetration.
Avoid bending the pipes unnecessarily.
This minimises pressure loss in the refrigerant pipes
and guarantees that the compressor oil can flow
freely.
If the outdoor unit is mounted above the indoor unit,
you must take steps to recirculate the oil.
See section on oil recirculation.
Do not set up the unit in the direct proximity of de-
vices that emit intense heat, such as glass reflection
surfaces.
If the unit is assembled close to heat emissions, the
amount of warm air expelled by the plate fins of the out-
door unit is reduced.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO ML680 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO ML680

REMKO ML680 Bedienungsanleitung - Deutsch - 28 seiten

REMKO ML680 Bedienungsanleitung - Holländisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info