REMKO PGT (E) series
Unit description
The units are mobile fan-assisted
air heaters (WLE) directly fired
with liquid gas, without a heat
exchanger.
The units operate without
an exhaust gas connection
and are designed exclusively
for commercial use.
The units are equipped with
integrated power regulation
for the stepless control of
the heating capacity, quiet and
low-maintenance axial fans,
robust gas burners with thermal
flame monitoring, electric solenoid
valves, electric ignition, room
thermostat socket and mains cable
with earthed safety plug.
The units conform to
the fundamental health and safety
requirements of the appropriate
EU stipulations, and are simple
to operate.
The units are EC type-tested,
DVGW-registered and approved
for EU countries.
The units may be used among
other things for the following:
Drying newly completed
buildings
Spot heating of outdoor
workplaces
Spot heating workplaces
in open, non-flammable
manufacturing facilities and
halls
Temporarily heating enclosed
spaces with a sufficient fresh air
supply
De-icing machines, vehicles and
non-combustible warehoused
goods
Maintaining the temperature
of frost-sensitive parts
Operating sequence
Moving the operating switch
to the “I” position puts
the supply air fan into operation
and the program sequence
for the automatic burner is started.
After a few seconds, the electric
solenoid valve opens the gas
supply to the burner. The liquid
gas is transported through a nozzle
under pressure into the mixing
tube. Here, the gas is enriched
with a quantity of oxygen aligned
with the unit output.
The gas/air mixture is ignited
at the burner head by an
electric ignition spark. Ignition
is automatically ended as soon
as a flawless flame burns, and
the automatic burner has taken
over the flame monitoring.
Regulation of the min/max heating
capacity can be implemented on a
stepless basis during unit operation
on the integrated “power
regulation”.
Monitoring the units
It is possible to safely monitor all
functions with the safety devices
of the units.
In the event of irregularities or if
the flame is extinguished, the units
are switched off and interlocked.
Safety
temperature limiter (STB)
The units are equipped with a
safety temperature limiter (STB),
which interrupts the gas supply in
case of overheating and electrically
interlocks the unit.
A manual reset of the STB can only
be implemented after the units
have cooled down.
The STB is reset by actuating
the reset key 2.
1. Unscrew the protective cap 1.
2. Push in key 2.
3. Screw the protective cap 1 back
on again.
Automatic burner
In the event of irregularities
or if the flame is extinguished,
the automatic burner switches
off and interlocks the units.
The unit's fault lamp will light up
in this case.
The automatic burner is unlocked
by pressing the malfunction
button.
The automatic burner can
be unlocked after a waiting time
of approx. 60 sec.
1
2
CAUTION
If the safety temperature
limiter has been triggered,
the cause of the malfunction
must be identified and rectified
before a reset is performed.
NOTE
Before resetting safety
equipment, the cause
of the malfunction must
be identified and rectified.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

remko-pgt-100

Suche zurücksetzen

  • Schalter auf Heizen Gerät zündet aber der Lüfter läuft nicht an Eingereicht am 14-12-2022 08:14

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO PGT 100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO PGT 100

REMKO PGT 100 Bedienungsanleitung - Deutsch - 28 seiten

REMKO PGT 100 Bedienungsanleitung - Holländisch - 24 seiten

REMKO PGT 100 Bedienungsanleitung - Französisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info