Issue GB – W04
REMKO RKL
RKL 490 DC
Mobile Inverter Air Conditioning Unit in Split Design
Operation · Technology · Spare parts
Contents
Read these operating instructions carefully before
commissioning / using the device!
These instructions are an integral part of the system and must always
be kept near or on the device.
This operating manual is a translation of the German original, Version W-04
Subject to modifications; no liability accepted for errors or misprints!
Safety notes
4
Environmental protection and recycling
4
Warranty
4
Intended use
4
Transport and packaging
5
Equipment description
5
Operation
6-7
Installation instructions
7-8
Connector pipes
9-10
Shut-down
11
Troubleshooting and customer service
11
Care and maintenance
12
Electrical connection diagram
13
Exploded view and parts lists
14-17
Technical data
18
Declaration of conformity
19
Made by REMKO
3
Safety notes
Disposal of equipment and
components
Only recyclable materials are used
in the manufacture of the devices
and components.
Help protect the environment by
ensuring that the devices or com-
ponents (for example batteries) are
not disposed in household waste,
but only in accordance with local
regulations and in an environmen-
tally safe manner, e.g. using certi-
fied firms and recycling
specialists or at collection
points.
Intended use
Depending on the model, the
equipment and the additional
fittings with which it is equipped
is only intended to be used as an
air-conditioner for the purpose of
cooling or heating the air in an
enclosed room.
Different or additional use shall
not be classed as intended use.
The manufacturer/supplier assumes
no liability for damages arising from
an unintended use of the equip-
ment. The user bears the sole risk in
such cases.
Using the equipment as intended
also includes working in accord-
ance with the operating manual
and installation instructions and
complying with the maintenance
requirements.
Carefully read the operating in-
structions before commissioning the
equipment for service. It provides
useful tips and information as
well as hazard warnings to prevent
injury or material damage . Fail-
ure to follow the directions in this
manual can result in endangerment
to persons, the environment and
the equipment itself and will void
any claims for liability.
Keep this manual and the refrig-
erant data sheet near the unit.
The unit should be set up and
installed only by qualified per-
sonnel.
The set-up, connection, and
operation of the unit and its
components must be in accord-
ance with the operating condi-
tions stipulated in this manual
and comply with all applicable
local regulations.
Mobile units must be set up
securely on suitable surfaces and
in an upright position. Station-
ary units must be permanently
installed for operation.
Modification of equipment and
components supplied by REM-
KO is not permitted and can
cause malfunctions.
Equipment and components
may not be operated in areas
where there is an increased risk
of damage. Observe the mini-
mum clearances.
The electrical supply is to be
adapted to the requirements of
the equipment.
The operational safety of equip-
ment and components is only
assured if they are fully as-
sembled and used as intended.
Safety devices may not be modi-
fied or bypassed.
Do not operate equipment or
components with obvious de-
fects or signs of damage.
All housing parts and openings
in the device, e.g. air inlets and
outlets, must be free of foreign
objects, fluids, or gases.
The equipment and components
must be kept an adequate dis-
tance from flammable, explo-
sive, combustible, abrasive and
dirty areas or atmospheres.
Touching some parts of the
equipment can result in burns or
other injury.
Installation, repair and mainte-
nance work may be carried out
only by authorised specialists.
Visual inspections and cleaning
can be performed by the opera-
tor as long as power is discon-
nected from the equipment.
To preclude any danger from
the equipment, take appropri-
ate hazard-prevention measures
when performing installation,
repair or maintenance work or
cleaning the equipment.
The equipment or components
are not to be exposed to any
mechanical stresses, extreme
levels of humidity or direct
sunlight.
Warranty
Prerequisites for possible warranty
claims are customer or his accept-
ing representative has completely
filled out the "warranty registration
card" supplied with the unit and
was completely filled out and re-
turned to REMKO GmbH & Co. KG
and placing the unit in service.
The warranty conditions are listed
in the "General terms and condi-
tions". Furthermore, only the par-
ties to a contract can strike special
agreements beyond these condi-
tions. For this reason please contact
your contractual partner in the first
instance.
Disposal of packaging
All products are packed for trans-
port in environmentally friendly
materials. Make a valuable con-
tribution to reducing waste and
sustaining raw materials. Only
dispose of packaging at approved
collection points.
Environmental
protection
and recycling
REMKO RKL
4
The device is particularly suited for
flexible operation, but can also be
mounted in a stationary installa-
tion.
The mobile air conditioning unit
is comprised of an indoor unit for
setting up on the floor indoors and
an outdoor unit for wall or ground
installation outdoors. In "cooling"
mode, the output produced by the
compressor precisely matches itself
to requirements, and thereby regu-
lates the nominal temperature with
minimal temperature deviations.
This "inverter-technology" results
in energy savings over conventional
split systems and also reduces noise
emissions to a particularly low level.
The flexible connection pipe serves
to transport the heat outdoors.
The outdoor unit discharges the
absorbed heat to the outdoor air
by means of a heat exchanger
(condenser). The condensate col-
lected during cooling operation is
transported to the outdoor unit
by means of a condensate pump
integrated into the indoor unit and
evaporates via the heat exchanger.
The device filters and dehumidi-
fies the air and thereby creates
a comfortable room climate.
It works fully automatically and
offers numerous additional op-
tions thanks to its microprocessor
control system. The device can be
conveniently operated by means
of the infrared remote control unit
included.
Equipment description
The equipment is shipped in sturdy
transport packaging. Immediately
check the equipment on delivery
and make note of any damage or
missing parts on the delivery note
and inform the forwarding agent
and your contractual partner.
No warranty can be assumed for
later claims.
Transport and
Packaging
Connector pipes
Air filter
Mount for
the outdoor unit
Air intake
Cover
Mains lead with plug
Condensate
drain
Rear view (indoor unit)
Air outlet
Control panel
Recessed grip
Air intake
Indoor unit Outdoor component
Front view
Condenser fan
(back side)
Connector pipes
Air outlet
Conveyor rollers
Carrying
handle
Ventilation louvers
Infrared receiver
5
The system can be operated by means of the control panel on the device or via the standard infrared remote
control unit. The functional operation of the buttons among themselves is identical, however, the designation
can vary. The batteries must be correctly inserted before the infrared remote control is used.
Operation
Legend
"ON / OFF" button
"MODE" button
(Fan speed – mode)
The fan speed is indicated by
means of LEDs in the selected
modes AUTOHIMEDLO or
circulated air modeFAN.
LED "COMP. ON"
(Compressor operation)
The controller controls the cool-
ing output by means of switch-
ing the compressor on or off.
Compressor operation is indicat-
ed by means of the LED. If the
LED flashes, the compressor will
be activated in max. 3 mins.
Button " "
Temperature setting
The desired nominal temperature
can be set with the ▼▲ buttons
in steps of 1°C between 16 and
30°C.
On and off timer
The timer function can be used
to switch the device on or off
automatically in hourly intervals
("▼▲" buttons) by means of
pressing the "SET" button. The
function can be used to program
the switch-on timer when the
device is off and the switch-off
timer when the device is on, for
up to 24 hours. Both timers can
be deleted by means of pressing
the "RESET" button.
AUTO SWING button
The direction of the discharged
air via the oscillating fins can be
adjusted to fixed or oscillating
by pressing the "AUTO SWING"
button.
LED "DRAIN WATER"
If the pump is unable to trans-
port the collected condensate
then this is signalised via an
acoustic alarm in combina-
tion with the flashing "DRAIN
WATER" LED. The device will
be operational again after the
container is emptied by means
of the condensate drain.
Display
The display shows the set nomi-
nal temperature or the residual
time of a programmed timer.
Infrared receiver
The device receives the signals
from the infrared remote con-
trol via the sensor.
FAN button
The ventilator speed can be
adjusted by means of pressing
the "FAN" button.
Cooling mode
1. Switch the unit on by means of
the "I / 0" button.
2. Set the temperature selection
switch to the desired nominal
temperature.
3. Select the desired fan mode
to AUTO, HI, MED or LO by
means of the "MODE" button.
Circulated air
1. Switch the unit on by means of
the "I / 0" button.
2. Select FAN mode by means of
the "MODE" button.
The outdoor unit can remain in the
room in circulated air mode.
However, do not hang the outdoor
unit onto the indoor unit.
Dehumidifying mode
Position the indoor unit and the
outdoor unit in the room that is to
be dehumidified.
1. Ensure that the indoor unit can-
not extract warm air from the
outdoor unit.
2. Do not hang the outdoor unit
onto the indoor unit.
3. Please observe: The condensate
formed during dehumidifica-
tion may not be pumped to the
outdoor unit as otherwise it will
be dissipated back into the air
in the room or may run out of
the outdoor unit.
Control panel
FAN
TEMP.
ON/OFF
FUZZY
C
TIMER
MODE
infrared remote control
Infrared transmitter
REMKO RKL
6
Installation instructions
The device is supplied in a fully op-
erational condition and is equipped
as standard with a connection pipe
linking the indoor and outdoor de-
vices, meaning that it is ready for
use. The scope of delivery includes
various accessories for mounting
the outdoor unit.
The indoor unit
The indoor unit is positioned at the
desired location with the air dis-
charge side pointing into the room.
When positioning, ensure there is
a minimum gap of 20 cm around
the device.
Connector pipes
The connector pipes can be
laid through a tilted window
or through a gap in the door.
The connector pipe can be sepa-
rated from the indoor unit, mean-
ing that there is the additional
option of fitting it to a wall open-
ing (Ø min. 60 mm).
Please note the following information
when laying the connector pipes:
The connector pipes may not
be jammed in or kinked.
There may not be any ten-
sion of other mechanical stress
exerted on the connector pipes.
The pipe insulation and the
protective jacket may not be
damaged.
Outdoor component
The outdoor unit expels the heat
from the room into the outside air.
In order to do so, the outdoor unit
can be positioned on the ground
or mounted on an external wall.
Installation on the ground
It is not necessary to use any
mounting accessories when install-
ing the outdoor unit on a patio or
balcony.
The outdoor unit should be po-
sitioned vertically and protected
from direct sunlight. A minimum
gap of 20 cm should be main-
tained from the air discharge side
to the wall.
It must be ensured that the air can
be discharged freely (min. 50 cm
gap to any obstacles).
The connecting pipe is fed through
a gap in the window or door
(Fig. 2 and 3).
20 cm
20 cm
3 Example assembly outdoor unit
2a Absence of minimum gap
2 Minimum clearance to wall
4. Take the condensate drain hose
on the back of the indoor unit
out of its bracket and remove
the plug.
5. Allow the condensate to drain
downwards into a drain or con-
tainer.
Ensure that the external
container does not overflow.
This could result in water
damage.
!
CAUTION
6. Switch the unit on by means of
the "I / 0" button.
7. Set the temperature selection
switch to the lowest nominal
temperature.
8. Set the "MODE" button to the
lowest fan speed "LO".
7
Mounting on an external wall
with wall bracket
Fasten to the wall using the
supplied wall bracket.
Hook the outdoor unit into the
wall bracket and secure it with
the supplied M4 bolts
(Fig 4 and 5).
The wall brackets can be fastened
with the supplied fastening ele-
ments (dowel 6mm and screws).
External wall mounting with
fastening straps
Fastening straps are an additional
option for mounting the outdoor
unit to an external wall or parapet
wall.
Hook the wall bracket onto the
outdoor unit and secure it with
the screws (M4).
Hook one end of the fasten-
ing strap with the spring catch
into the fastening eyelet of the
outdoor unit.
Hook the other end of the fas-
tening strap into the eyelet bolt
which is to be attached to the
on-site external wall or parapet
wall (Fig. 7).
Ensure sufficient stability.
20 cm
max. 1.8 m
Spring catch
Fastening eyelet
Safety
bolt M4
Eyebolt
Safety bolt M4
353 mm
220 mm
Should this not be suitable for the
characteristics of the wall then
the fastening elements should be
selected on site to ensure suitable
holding force.
When mounting, ensure that the
cable is not stressed and that the
insulation is not damaged in the
process.
Maintain the minimum gaps.
The air outlets of the indoor and
outdoor units may not be blocked.
Mounting height
The outdoor unit (lower edge) may
only be mounted max. 1.8 m
above the installation level of the
indoor unit (Fig. 6). If the outdoor
unit is mounted below the installa-
tion level of the indoor unit, then
the height difference may not
exceed 1.5 m.
4 Required air circulation
5 Gaps assembly bracket 6 Max. assembly height 7 Assembly with fastening straps
Depending on weather conditions it is possible that condensate will
run out of the condensate drain on the rear of the outdoor unit.
This is a normal process. Select the installation site for the outdoor
unit in such a way as the draining water cannot cause any form of
damage or hook up the connection to a drain.
NOTE
REMKO RKL
8
Connector pipes
The device can be disconnected
and reconnected approx. 7
times without experiencing
a noticeable loss of cooling per-
formance, assuming the work is
carried out properly.
In doing so, the following proce-
dure must be adhered to:
1. Switch the unit off.
2. Remove the mains plug from
the mains socket.
3. Remove the 2 screws from the
cover on the rear side of the
device (Fig 8).
4. Remove the cover from the unit.
5. Unscrew the cable strap from
the connection pipe (Figure 9).
6. Push in the side clips on the
plugged connection and pull
the plug out of the socket
(Figure 9).
7. Remove the upper section
from the bracket by means of
unscrewing the two screws
(Figure 9).
8. Unscrew the condensate drain
hose (Fig 9).
9. Unscrew the left-hand union
nut with the SW 24 open-end-
ed spanner provided. In doing
so, use the second SW 21
open-ended spanner to hold
the lower coupling section still
(Fig. 10, page 10).
The connection pipe is connected
to the indoor unit with quick-
release couplings.
This offers the option of discon-
necting the connection pipe for
purposes of assembly without the
risk of losing refrigerant.
The unit must be disconnected
from the mains supply during
the entire process! It may only
be switched back on when all
of the connections have been
made and checked. The fas-
tenings and all of the covers
must be attached beforehand.
!
CAUTION
Connector pipes
Cable strap
Plug connection
Condensation hose
Cable strap
9
Dismantling the connection pipe
It is possible that residual fluid
can leak out of the the con-
densate hose.
NOTE
Cover
Screws
8 Rear view - indoor unit
Never twist the the fixed lower
section.
!
CAUTION
Instructions for disconnecting the
connector pipes:
Disconnect the devices only im-
mediately before assembly and
only leave the devices discon-
nected for as long as is abso-
lutely necessary.
Before the pipes are reconnect-
ed, it is to be ensured that there
is no dirt, moisture or other for-
eign bodies in the quick release
couplings which could impair
their function.
Always mount the cable strap
as soon as the pipelines are
connected.
The pipelines may only be
disconnected and connected by
authorised specialist engineers.
Suitable protective gear must
be worn when connecting or
disconnecting the connection
pipe.
!
CAUTION
9
10. Screw continuously until the
connection is disconnected.
11. Unscrew the right-hand union
nut with the SW 24 open-end-
ed spanner provided.
In doing so, use the second
SW 21 open-ended spanner to
hold the upper coupling sec-
tion still (Fig. 11).
12. Screw continuously until the
connection is disconnected.
13. Screw the protective caps
provided onto the 4 coupling
halves (Fig. 12).
14. Ensure that there is a wall
opening available of Ø 60 mm
in the event that the connec-
tion pipe is to be fed through
a wall.
15. After the placement or mount-
ing of the indoor unit and
outdoor unit is complete, the
connection pipe can be hooked
up to the indoor unit in the op-
posite order.
16. After making the connections,
check the quick-release cou-
plings for leaks.
Protective caps
Protective caps
12 Screw on protective caps
Do not stop screwing in the
event that refrigerant escapes
and a slight hissing sound is
heard.
NOTE
Never twist the the fixed upper
section.
!
CAUTION
Do not stop screwing in the
event that refrigerant escapes
and a slight hissing sound is
heard.
NOTE
Release counter pressure
10 Unscrew the left-hand union nut
Cable strap
dismantle
tighten
11 Unscrew the right-hand union nut
release counter
pressure
release
tighten
REMKO RKL
10
Shut-down
Temporary shut-down
If it is planned to shut down the
equipment for longer periods e.g.
during the winter, proceed as fol-
lows:
1. Allow the equipment run for
2-3 hours in circulation mode.
This extracts any residual hu-
midity from the unit.
2. Shut down the equipment by
pressing the "I / 0" button on
the operating panel. Only then
The unit has been manufactured using state-of-the-art production methods and tested several times to ensure
its correct function. If malfunctions should occur, please check the unit as detailed in the list below. If all func-
tional checks have been carried out and the device still fails to operate properly, then please notify your nearest
specialist dealer.
Troubleshooting and customer service
Fault Possible cause Remedial measures
The unit does not start
Mains failure
Check voltage and if necessary wait until
power is back on
Mains fuse or controller fuse faulty Arrange to have exchanged
Mains plug not inserted in socket Insert mains plug
Condensate container full, display "DRAIN
WATER" flashes
Empty container via condensate drain hose
Timer mode active
Wait for timer period to expire or
press "I / 0" button again
The unit is running with
Reduced ventilation output
Used air or outlet openings soiled or blocked
by foreign bodies
Clean the openings
Remove foreign bodies
Filter soiled
Clean the filter in accordance with the instructions
Outdoor unit soiled
Clean the fins on the inside of the outdoor
unit
Cooling load of the room excessive Reduce the thermal load
Condensate leaks out of
the unit
Device standing at an angle Position vertically, ensure stable positioning
Plugs missing from condensate
drain hose
Seal the hose so that it is watertight again
should you pull out the mains
plug and wind up the cable.
3. Empty the internal condensate
container via the condensate
drain hose on the rear side of
the indoor unit.
4. Make sure that there is no
condensate in the outdoor unit
before storing the indoor and
outdoor unit indoors. To drain
the condensate, remove the
plug from the outdoor unit.
5. Clean the filter and the plastic
surfaces.
6. Hang the outdoor unit onto the
indoor unit.
7. Cover the equipment with
a synthetic tarpaulin to protect
it against dust.
8. Store the equipment in a cool
and dry location away from
direct sunlight.
Permanent shut-down
The entire system should only be
dismantled by a specialist firm
familiar with all environmental
aspects involved.
REMKO GmbH & Co. KG or your
sales partner will be be pleased to
provide details of refrigerant spe-
cialists in your area.
Never switch off the equip-
ment by pulling out the mains
plug.
NOTE
11
Care and maintenance
Regular care and observation
of some basic points will ensure
trouble-free operation and a long
service life of the unit.
The device should be checked and
thoroughly cleaned after each pro-
longed use, but in any case at least
once per year.
The entire plant is designed as
a maintenance free, hermetically
sealed system and may only be
maintained or repaired by specialist
authorised firms.
Clean the equipment using a
damp cloth.
Do not use a jet of water.
Do not use any caustic, abra-
sive or solvent-based cleaning
products.
Only use suitable cleaning
agents, even in the event of
severe soiling.
Empty the condensate con-
tainer and check if the diameter
of the condensate lines have
tapered as a result of soiling
prior to and after each operat-
ing season.
If this is the case, they must be
cleaned.
Clean the air filter on the indoor
unit at regular intervals, and
more frequently if necessary.
It is recommended that you take
out a maintenance contract with
an appropriate specialist firm.
Air filter for indoor unit
Clean the air filter at intervals of
no more than 2 weeks. Reduce this
interval if the air is especially dirty.
Cleaning the filter on the in-
door unit
Please proceed as follows in order
to clean the unit:
1. Remove the mains plug.
2. Pull the filter out of the unit
(Fig 1).
3. Clean the filter of dust.
Use a vacuum cleaner in the
event of slight soiling.
3. In the event of more severe
soiling, carefully clean in luke-
warm water.
4. Subsequently allow the filter to
dry in the air.
5. Insert the filter back into the
device.
Prior to performing any work,
ensure the equipment is dis-
connected from the voltage
supply and secured to prevent
accidental switch-on!
!
CAUTION
Never operate the indoor unit
without the original filter.
The heat exchanger fins on
the indoor unit with soil up if
operated without a filter and
the device will suffer perform-
ance loss.
NOTE
Filter
1 Remove filter
This enables you to ensure
the operational reliability of
the plant at all times!
TIP
Check the level of dirt on the
on the
exchanger fins.
NOTE
REMKO RKL
12
Electrical connection diagram
Legend
PCB 1 = Control board
PCB 2 = main board
SM = Swing Motor
FM 1 = Vaporiser fan
FM 2 = Condenser fan
WM = condensate pump
CM = Compressor
OLP = Compressor excessive temperature protection
CX 1 = Condenser, vaporiser fan
CX 2 = Condenser vaporiser fan
CX 3 = Condenser compressor
RT = Sensor circulating air temperature
CT = sensor frost protection
MS 1 = Microswitch alarm (container full)
MS 2 = Microswitch condensate pump
Colour code
Y = yellow
W = white
R = red
BU = blue
BR = brown
BK = black
GR = Grey
OR = orange
13
Exploded view indoor unit
We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process.
3
37
38
22
23
6
5
4
2
2
1
24
30
19
18
17
21
20
25
26
27
40
39
34
33
35
28
32
29
7
9
8
41
14
13
11
12
10
36
31
15
42
43
REMKO RKL
14
Spare parts list
When ordering spare parts, please state the computerised part no., unit number and type (see identification plate)!
No. Designation RKL 490 DC
RKL 490 DC
1 Front panel 1106060 1106120
2 Recessed grip 1106061 1106121
3 Cover, top 1106062 1106062
4 Exhaust grille 1106063 1106063
5 slats 1106064 1106064
6 Shift lever for fins 1106065 1106065
7 Back wall 1106066 1106122
8 Air filter 1106067 1106123
9 Cover for connection pipe 1106068 1106124
10 Device base 1106069 1106069
11 Base plate, cpl. 1106070 1106070
12 Conveyor rollers 1106071 1106071
13 Side cover, right / left 1106072 1106072
14 Condensate container 1106073 1106073
15 Partition wall 1106074 1106074
17 Holder for microswitch 1106076 1106076
18 Microswitch, (container full) 1106077 1106077
19 Microswitch, (pump on / off) 1106078 1106078
20 Float, (container full) 1106079 1106079
21 Float, (pump on / off) 1106080 1106080
22 Swing motor for fins 1106032 1106032
23 Coupling for swing motor 1106081 1106081
24 Condensation pump cpl. 1106082 1106082
25 Electrical terminal strip 1106083 1106083
26 Condenser, vaporiser fan 1106002 1106002
27 Condenser, liquefier fan 1106003 1106003
28 Frame, rear right 1106085 1106085
29 Fan, cpl. 1106099 1106099
30 Vaporiser fan 1106087 1106087
31 Compressor, cpl. 1106148 1106148
32 Vaporiser 1106142 1106142
33 Coupling, set (1x m / 1x w) 1106139 1106139
34 Connection pipe, cpl. 1106140 1106140
35 fastening block, cpl. 1106093 1106093
36 Condensate drain hose 1106094 1106094
37 Keypad board 1106143 1106143
38 Keypad foil 1106144 1106144
39 Control board 1106145 1106145
40 IPM protection board 1106180 1106180
41 Mains cable with plug 1106146 1106146
42 Main board 1106149 1106149
43 Condenser board 1106181 1106181
Spare parts (not illustrated)
Sensor frost protection 1106131 1106131
Covering for fan 1106075 1106075
Air circulation sensor 1106098 1106098
15
Exploded view outdoor unit
60
50
52
61
57
55
54
58
51
53
59
REMKO RKL
16
We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process.
Spare parts list
When ordering spare parts, please state the computerised part no., unit number and type (see identification plate)!
No. Designation RKL 490 DC
RKL 490 DC
50 Back wall 1106100 1106125
51 Front panel 1106101 1106126
52 Device base 1106102 1106102
53 Covering for fan 1106103 1106103
54 Condenser fan 1106105 1106105
55 Fastening for vaporiser fan 1106106 1106106
56 Mounting angle 1106107 1106107
57 Vaporiser fan, outdoor unit 1106108 1106108
58 Condenser 1106147 1106147
59 Seal 1106110 1106110
60 Wall bracket 1106111 1106111
61 remote control 1613138 1613138
Spare parts (not illustrated)
Condenser, compressor 1106118 1106118
Fastening set for outdoor unit, cpl. 1106112 1106112
17
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für REMKO RKL490 DC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von REMKO RKL490 DC

REMKO RKL490 DC Bedienungsanleitung - Deutsch - 16 seiten

REMKO RKL490 DC Bedienungsanleitung - Holländisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info