585218
6
Zoom out
Zoom in
Vorherige Seite
1/9
Nächste Seite
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
Example for the heating mode
If the room thermostat serves a frost monitor and should keep the room temperature
of e.g. a storage room or cellar above +5 °C, connect the front outlet of the room
thermostat to a heater, such as a convector.
Turn off the room thermostat and check which operating mode is currently installed
(“
“ = Heating mode, “ “ = Cooling mode).
Choose Heating mode as the operating mode.
Switch on the room thermostat. The control-LED (1) must now light up (LED is red =
the front outlet is deactivated, LED is green = the front outlet is activated).
Set a temperature limit of +5 °C with the buttons “F“ (7) and “S“ (8). The room ther-
mostat is therefore ready for operation.
If the room temperature falls under +5 °C for longer than 1 minute, the room ther-
mostat will turn on the connected heater. The control-LED (1) lights up green, and
additionally the symbol “
“ appears.
The time period of 1 minute serves to prevent the connected heater from
being switched on or off in succession too quickly.
If the room temperature rises higher than +5 °C, the room thermostat turns off the
connected heater again. The control-LED (1) lights up red, and the symbol “
“ dis-
appears again.
Example for the cooling mode
If the room thermostat is to keep a room from excessively high temperatures, con-
nect the front outlet of the room thermostat to a ventilator for example (or a suitable
air conditioner).
Turn off the room thermostat and check which operating mode is currently installed
(“
“ = Heating mode, “ “ = Cooling mode).
Choose Cooling mode as the operating mode.
Switch on the room thermostat. The control-LED (1) must now light up (LED is red =
the front outlet is deactivated, LED is green = the front outlet is activated).
Set a temperature limit of +25 °C with the buttons F(7) and S(8). The room
thermostat is therefore ready for operation.
If the room temperature rises over +25 °C for longer than 3 minutes, the room ther-
mostat will turn on the connected ventilator (or an air conditioner). The control-
LED (1) lights up green, and additionally the symbol “
“ appears.
The time period of 3 minutes serves to prevent the connected air conditioner
from being switched on or off in succession too quickly.
If the room temperature falls below +25 °C, the room thermostat will turn the con-
nected ventilator (or a air conditioner) off again. The control-LED (1) lights up red,
and the symbol “
“ disappears again.
Maintenance and care
The product does not require maintenance. The product contains no parts that re-
quire servicing. Therefore, do not open/dismantle it. Maintenance or repair may only
be performed by qualified personnel or a specialised repair shop.
Before cleaning, disconnect the room thermostat from the power supply. To do this,
pull it completely out of the mains socket. Then disconnect the room thermostat
from the connected device.
To clean the product, a clean, dry and soft cloth is sufficient.
Dust can be easily removed using a clean, soft and long-bristled brush and a vacu-
um cleaner.
Do not use abrasive cleaning agents, rubbing alcohol or other chemical so-
lutions, which may damage the casing or even impair operation.
Disposal
The product must not be disposed of in the household waste!
Please dispose of the product, when it is no longer of use, according to the
current statutory requirements.
Technical data
Connection data ......................................230 V/AC, 50 - 60 Hz
Connection power...................................Ohmic load: max. 3680 W (230 V/AC, 16 A)
....................................................................Inductive load: max. 460 W (230 V/AC, 2 A)
Devices with mainly resistive load are e.g., light bulbs, heaters, etc.
Devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy saving bulbs, etc.
Switch type ..............................................Relay (single-pole)
Temperature setting range ....................+5 °C bis +30 °C
Accuracy ..................................................±1 °C
Backup battery ........................................
yes, built-in permanently (NiMH, 2,4 V, 40 mAh);
Charging time ca. 8 - 12 h, Back-up time ca. 200 h
Socket with child protection .................yes
Ambient conditions ................................. Temperature 0 °C to +40 °C; humidity 20% to
90%, non-condensing
Dimensions...............................................60 x 110 x 77 mm (W x H x D, including plug)
Weight .......................................................136 g
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Renkforce MH-850T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info