CHANGING THE DRAW PLATE
(Fig. 5)
If the draw plate or the draw-deflector is to
be replaced on your firing appliance, lift the
draw plate slightly to the side and remove
the side fireclay component.
You can now tilt the draw plate and remove
it from the firebox opening.
Before initial commissioning or after re-loca-
ting the appliance, cleaning and servicing,
make sure that the draw plate (Fig. 5, Part
18), and the wood collector (Fig. 5, Part 21)
are correctly positioned.
When using a flue with a throttle flap, this
must be open.
On this firing appliance, it is necessary to
ensure that the chimney draft reaches at
least the prescribed value (> 0.8 mbar).
If there is a problem in achieving this value,
contact your chimney sweep/maintenance
engineer.
CONNECTION TO THE CHIMNEY
On establishing a new connection in a
brick-built chimney, the following proce-
dure is recommended:
1. Measure out and mark-of
f the position
of the chimney connection (if necessary,
taking account of the base plate thick-
ness).
First seal the shell lining with mineral wool.
Then fill the area with heat-resistant mortar
or equally suitable filler.
4. When the mortar has hardened and
a
fter the filling and smoothing
, position
the base pla
te and floor prot
ection
(Cart
on).
5. The unit can now be lifted carefully onto
the base plate.
Under no circumstances must the appliance
be pushed over an unprotected floor.
A suitable covering for the floor is provided
by using strong corrugated paper, carton or,
for example, a piece of used carpet. The
aplliance can be safely pushed over such a
protective layer.
If you do not use our original flue compo-
nent for the chimney connection, then we
recommend the use of a tube manufactured
from steel sheet at least 2 mm thick. Under
no circumstances must the connection
component protrude into the chimney
duct itself! Seal the gap between the flue
pipe and the shell lining with a ceramic seal.
The installation must satisfy the relevant
safety and building regulations. Please contact
your registered chimney sweep/maintenance
engineer. Who will be pleased to advise you.
ENGLISH
24
2. INSTALLATION OF THE APPLIANCE
If you use a “system” chimney (e.g. glazed
fireclay) - we would advise you to follow
precisely the connection instructions of the
manufacurer.
INSERTING THE WHETSTONE PANELS
Insert the lugs on the pre-mounted carrier
plate of the (Right or left) whetstone panel
(With the opening pointing downwards)
into the cut-out slots on the oven side wall
and allow the whole panel unit to slide
slowly downwards, whilst pressing against
the oven body. Insert the opposite panel by
the same method.
2. Chisel out (or drill out) the hole in the
masonry w
ork.
3. Brick in the shell lining.