2. MODES
Note
When operating correctly, the stove may not be overheated. However
improper operation can shorten the life expectancy of electrical components
(blowers, motors and electrical control) and is not allowed!
Operation Modes Manual/Automatic/Comfort
The recommended heat output is in the range between
50% -100%. If you want to select a lower heating power, stay for about 2
seconds on the MINUS button. Then you can adjust the heat output in the range
between 30% and 50%.
Tip
Within the recommended range of 50% - 100% output the sooting of the
combustion chamber and door glass is reduced.
MANUAL MODE
The pellet burner start and stop (ON / OFF buttons) and set the desired heat
output (PLUS / MINUS buttons) can be done on the touch screen directly at the
HOME main menu.
AUTOMATIC MODE
The change from the operating status “STOVE OFF“ to STANDBY-status (ON
button) and from STANDBY-status to STOVE OFF (OFF button) is made by
pressing the screen buttons directly in the HOME - main menu. The desired heat
output (PLUS / MINUS buttons) is also set here.
The heating time program regulates the change between STANDBY-status and
CONTROL MODE automatically.
Tip
If no heating times are stored the icon „heating times“ flashes and the stove
remains in standby.
The pellet burner start is within the heating times.
The pellet burner stop is outside the heating times.
In the operating status STOVE OFF no automatic pellet burner start is possible,
the system is turned off.
COMFORT MODE
The change from the operating status “STOVE OFF“ to STANDBY-status (ON
button) and from STANDBY-status to STOVE OFF (OFF button) is made by
pressing the screen buttons directly in the HOME - main menu. The desired
room temperature (PLUS / MINUS buttons) is also set here.
In the COMFORT mode heating times can be activated additionally.
The pellet burner start is within the heating times (or always with heating
times deactivated) if the actual room temperature is below the desired room
temperature. In between the heating times the pellet burner starts if the actual
room temperature is below the decreasing temperature preset or if the frost
protection is activated.
The pellet burner stops either outside the heating periods, or if the actual room
temperature is higher than the desired room temperature.
In the operating status STOVE OFF no automatic pellet burner start is possible,
the system is turned off.
Emergency operation - heating up without
electrical Ignition
If the ignition cartridge fail, firelighters can be used for an emergency operation.
First, start the stove as usual. Wait for the turning of the grid (only for units with
turning grids). Then open the combustion chamber door and give a handful
of pellets with the firelighter into the clean burn pot, light it up and close the
combustion chamber door.
Note
Do not use flammable liquids to light up the fire!
Convection Fan - Control
(only for devices with convection fan, except type Interno)
Settings in the Setup menu
Convection Fan
You can switch on or off the convection fans as needed.
Conv. Fan Level
The convection fan speed is adjustable from level 5 (max.) to level 1 (min.). If
you continue to press the „minus“ button, you’ll set to AUTO. The convection
fan speed will be adjusted automatically depending on the heating power (30 -
100%). This setting should be chosen as standard.
Tip for MultiAir stoves
The manually speed settings are useful if, for example, the second room
needs to be heated up quickly or heat needs to be removed from the stove.
Conv. Fan Area
You can also adapt the convection fan speed (+/- 30% fan speed). This is applied
for manual and for the AUTO setting. The fan speed can be reduced if the noise
is perceived as too loud. Conversely, for MultiAir stoves, the performance can
be increased when generally too little heated air is passed into the next room.
only for stove Domo:
Convection Fan 1 / Convection Fan 2
Here you can make the settings for both fans. They are controlled independently
(as described above)
Convection Fan - Model Interno
To prevent overheating of the stove, the convection fan in the model Interno
can not be switched off. Once the stove is in operation, the convection fan
starts for safety reasons. The „AUTO“ setting can not be changed. A fan speed
adjustment can still be made.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rika Touch Display V2-14 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Rika Touch Display V2-14

Rika Touch Display V2-14 Bedienungsanleitung - Deutsch - 12 seiten

Rika Touch Display V2-14 Bedienungsanleitung - Holländisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info