LAHC5
CLASS 1 PRODUCT
CONTAINING
CLASS 3B LASER
808nm
wavelength
Wearing laser
safety goggles is
unnecessary as
the product has
been designed
with inbuilt safety
features.
PATENTS PENDING
This product MUST be used responsibly.
Please read these Instructions carefully
before use.
Refer to your Information Guide for:
• WARNINGS
• SECURITYBUTTONSEQUENCE
• HOWDOLASERSWORK?
• SUITABLESKINTYPES
• PATCHTEST
• HAIRGROWTHCYCLE
• WHYISASERIESOFTREATMENTS
REQUIRED?
• YOURQUESTIONSANSWERED
• TROUBLESHOOTING
SALON LASER
SCANNING HAIR REMOVER x60
WARNINGS
• Readallinstructionsthoroughlyandretainforfuturereference.
• NotsuitableforAfro-Caribbean, black skincomplexionsor forGreyHair.
See“SuitableSkinTypes”inInformationGuide.
• Laserhairremovalshouldnotcausediscomfort,youmayfeelindividualhairs
beingtreated,whichislikeamildpinprick,andaslightwarmingofthearea.
Ifyoufeelanydiscomfortorsorenessthesettingmaybetoohigh.
• Inbuiltsafetyfeaturesprotecttheeyebeingexposedtothelaser,however,
neveraimtheWandatorneareyes.
• DoNOTusenearflammablematerials.
• Keeptheproductoutofreachofchildrenandpets.
• ReflectionHazard:Pleaseremovealljewelleryinthevicinityofthetreatment
areabeforeuse.
• Whennotinuse,storethekeyresponsiblyinasafeplaceawayfromchildren.
• Donottreatthesamehairrepeatedlyinanyonesession.
• Donotuseafterdrinkingalcoholorifyouarefeelingunwellorfatigued.
• Donottreatthefollowingareas:tattoos,permanentmake-up,pimples,warts,
haironblackspotsormoles,darkfreckles,skindisease,birthmarks,burns,
lips,nipples,genitaloranalareas,eczema,eyelashes,eyebrows,nearthe
eyes,nasalorearhair.
• Thisisasensitivelaserscanningproduct.Careshouldbetakentoavoid
damagetothemechanismintheWand.
• Thisapplianceisnotintendedforusebypersonswithreducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
they have been given supervision or instruction concerning use of the
appliancebyapersonresponsiblefortheirsafety.
PRECAUTIONS
• DoNOTdismantleorrepair.Ifyouhaveanyproblemsusingtheproduct,
contactourCustomerCareDepartment.
• Misuseoftheunitcancauseharm.
• DoNOToverrideanysafetyfeaturesoropentheunitorwand.
• OnlyusethisproductwiththeMainsAdaptersupplied.
• KeepWandawayfromstrongelectromagneticfieldsandmagnetsduringuse.
PATCHTEST
IMPORTANT:24hoursbeforetreatmentitisveryimportanttodoapatchtest.
Thepatchtestwillconfirmthemaximumpowerlevelforyourskintype.Eacharea
tobetreatedmustbecheckedasskincolourcanvary.Pleaserefertothe‘PATCH
TEST’sectionintheInformationGuideandontheDVDforinstructions.
Aslightrednessmayoccur,butnotalways,withinanhouroftreatment.This
localisedrednessiscausedbythedestructionofthehairfolliclesandisquite
normal.However,ifanyrednessremainsafter24hoursthiswouldindicatethe
powerlevelselectedwastoohighforyourskintype.
GETTINGSTARTED
Please ensure you read the Information Guide and understand the
‘Warnings’ and ‘Product Safety’ sections before proceeding.
• Shavetheareatobetreated.Thisensuresthatthelasergoesdirectly
tothehairrootandavoidshairburningonthesurface.
• Removealljewelleryinthevicinityofthetreatmentarea.
• Pleaseensureyouhavepatchtestedtheareatobetreated24hours
prior to treatment.
STEP 1
ConnectMainsAdapterintotheDCPowerSocketat
thebackoftheunitandplugintotheMains.
STEP2
Unlock with Key to turn on. The light around the
Keyswitchwillflashgreen.
STEP 3
Enterthe“SECURITYBUTTONSEQUENCE”.
You will find the Security Button Sequence in the
Information Guide.
ThegreenlightaroundtheKeyswitchwillfullyilluminate.
Thelightsaroundthex60SCAN,x20SCANandSINGLE
buttonswillflashbluereadyforselection.Thebottom
PowerLevelIndicatorlightwillilluminate.
STEP4
Usethe+/-buttonstoselectthecorrectpowerlevel
foryourskintype.Refertothe‘PatchTest’sectionof
theInformationGuideforskintypes.
Each time the power setting is adjusted, you will
need to reselect x60 SCAN, x20 SCAN or SINGLE
modetocontinue.
Note:Ifnobuttonsarepressedafter20minutestheUnitwillenterenergy
savingmode.The orangelightwill flashandpower level1 will remainon.
TorestartturnkeyoffandbackonagainandstartatStep3.
ADDITIONALINFORMATION
STEP 8
Turn the Keyswitch anticlockwise to lock the unit.
RemovetheKeytoasafeplaceawayfromchildren.
Note: Ifyouexperienceunexpectedbehaviourofthisproductthenitispossible
someexternalelectromagneticinterferenceisresponsiblee.g.electricmotors/
loudspeakersetc.Youshouldremovethissourceandrestarttheproductto
restorefulloperation.Atnotimewillthelaserfireunintentionally.
‘SINGLE’HAIRTREATMENT
Youcanopttotreatsinglehairsusing
theSINGLEmode.
Press the ‘SINGLE’ button once.
TheSINGLEbuttonwillilluminateblue.
The orange light on the Wand
willilluminate.
FollowthesameprocedureforSCANtreatmentfromStep6,butthistime
pressing the SINGLE button.
InSINGLEmode,thebluelightaroundtheSINGLE
buttonwillflash.
Referto‘TreatmentArea’section,SINGLEmode.
SECURITY
BUTTON
SEQUENCE”
TREATMENTAREA
Asaguidetothetreatmentarea,asmallindentationmarkwillbeleftby
pressingtheWanddownontheskin.Inx60SCANmode,overlapping
theindentationmarkslightlywhenmovingtheWandineachdirectionwill
ensureeffectivecoverage.Inx20SCANmode,overlaptheindentation
markbyhalf.
SCANmodessequentiallytargetsinglehairsineachtreatment.
SINGLEmodeisfortreatingindividualhairs.Thetreatmentareaisinthe
centreoftheindentationguideandmeasures1mmx1mm.
‘SCAN’HAIRTREATMENT
STEP 5
Press the x60 SCAN button once. The
blue light around the button will fully
illuminate.Theorangelightonthewand
willilluminate.
Alternatively,pressthex20SCANbuttononce.
STEP6
Placethewandontheskinovertheareayouwishtotreat,
ensuringtheTouchPinsareincontactwiththeskin.
TheorangelightwillturnOFFandthewhite‘ready’light
willturnON.
ThebluelightsaroundtheSCANbuttonwillrotateto
indicatetreatmentisreadytostart.
STEP 7
Press and HOLD the Laser Button on the top of the
wandtostartlasertreatment.
The white light will flash on and off to indicate laser
treatmentisinprogressandtheunitwillbeeprepeatedly
(thiscanbemuted).Youwillnotbeabletoseethelaser.
You may feel individual hairs being treated, whichis
likeamildpinprick,andaslightwarmingofthearea
beingtreated.
Whenthelasertreatmentceases,theorangelightwill
comebackon.Youcannowmoveontothenextareaof
hairstobetreated.
Whenmovingthewandtothenextareaofhairstobe
treatedtheTouchPinsmustberemovedbrieflyfrom
theskin.
Refertoscanmodesin‘treatmentarea’section.
IMPORTANTNOTES - please read carefully
• DoNOTmovethewandduringtreatment.Youmaynoticethewandbecomes
warmduringusethisisquitenormal.
• IfcontactislostbetweentheTouchPinsandskinduringtreatment,thewand’s
orangelightwillcomeon.Treatmentwillresumewhencontactismadeagain.
• Foryoursafety,ifthewandisnotpositionedcorrectlyontheskinsurfacefor
treatment,thewhiteandorangelightswillflashalternatelyandoperationof
thelaserwillbedisabled.
• Sometimesyou cansmell faint burningor even seea very, smallline of
smokeasthehairistreated.
• Successfullytreatedhairsdonotalwaysfalloutimmediately,butareshed
over time as they are released from the hair follicle, light rubbing can
encouragethis.
• Youmayfeela‘pinprick’sensationduringtreatment.Anylocalisedrednessafter
treatmentiscausedbythedestructionofthehairfolliclesandisquitenormal.If
anyrednessremainsafter24hoursthiswouldindicatethepowerlevelselected
wastoohighforyourskintype.Pleaserefertothe‘PatchTest’sectioninthe
InformationGuide.Anylongerlastingrednesswillalsodisappear.
LASERHAIRTREATMENT
1
2
5
8
7
3
4
PresstheMUTEbuttononthebackoftheUnittoturn
offtheBeepnoises.Pressagaintoturnbackon.
Note: Thisdoesn’tturnoffwarningbleeps.
resettingafter‘lockout’
If you experience a ‘lockout’ as indicated by
repeatedflashingofanyofthebluepowerlights,
simplyresetbyturningtheunitoffusingthekey,
waiting5secondsandturningtheunitonagain.
cleaninglaseraperture
Periodically check whether there are any smoke
deposits on the Laser Aperture. A build up of
depositswillaffecttheefficiencyofthelaser.Ifyou
noticeanydeposits,switchtheunitOFFandunplug
themainsadapter.Thensimplycleanwithalintfree
clothorcottonbud,ensuringnofibresareleftinthe
LaserAperture.
x60 SCANmode
x20SCANmode
SINGLEmode
Rio,Dezac,SalonLaserScanningHairRemoverx60andLaserSafeTechnologyaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2011anufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
Overlapbyathird
Overlapbyhalf
treatmentarea
indentationmark
treatmentarea
indentationmark
treatmentarea
indentationmark
1-IN-LAHC5-UK/1.2
instructions
b
e
f
g
h
i
k
j
l
m
c
a
d
n
o
p
q
r
s
COMPONENTS
a. Mains Adapter
b. Keys
c. DC Power Socket
d. Mute Button
e. Keyswitch
f. Power Level Indicator
g. Power Increase Button (+)
h. Power Decrease Button (-)
i. x60 SCAN button
j. x20 SCAN button
k. SINGLE button
l. Hand-held Wand
m. Laser Button
n. Orange Light
o. White Light
p. Touch Pins
q. Laser Aperture
r. Indentation Guide
s. Front Face
laseraperture
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rio LAHC5 - Scanning Laser X60 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info