MIDI Implementatie
Data Set (DT1)
Status Data Bytes Status
F0H 41H,Dev,00H,4EH,12H,aaH,bbH,ccH,ddH, ..., eeH,Sum F7H
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
Dev Device ID
00H 4EH Model ID (MMP-2)
12H Command ID (DT1)
aaH Address MSB
bbH Address MID
ccH Address LSB
ddH Data
: :
eeH Data
Sum Check Sum
F7H EOX (End of System Exclusive Message)
The message is received under the following condition.
If the device ID on the message is same as that of the receive device, and the
address on the message correspond to the specified parameter base address, the
received data are stored from the specified parameter base address.
If the interval of received messages is shorter than 25m sec., the MMP-2 can not
work the receive message procedure correctly.
The message is transmitted under the following condition.
When the MMP-2 transmit the data on the requested parameter after receiving the
Data Request message(RQ1).
See Data Transfer Address Map (p. 47) for more details of the transfer
parameters.
Data Transfer Address Map
The each address value is expressed as a 7bit hex number.
+————————————————————————————————————————————————————————————————————————+
| Address | MSB | | LSB |
|—————————————————————+————————————————+————————————————+————————————————+
| Binary | 0aaa aaaa | 0bbb bbbb | 0ccc cccc |
| 7—bit Hex | AA | BB | CC |
+————————————————————————————————————————————————————————————————————————+
Parameter Address Block
<Model ID = 00H 4EH>
+————————————————————————————————————————————————————————————————————————+
| Start | |
|Address | Contents and Remarks |
|==========+=============================================================|
| 00 00 00 | System Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 00 01 00 | Input Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 00 02 00 | Effect Parameter (Temp) |
|——————————+—————————————————————————————————————————————————————————————|
| 00 04 00 | Status |
|——————————+—————————————————————————————————————————————————————————————|
| 00 05 00 | Remote Operation |
|——————————+—————————————————————————————————————————————————————————————|
| 01 00 00 | Bulk Data |
|——————————+—————————————————————————————————————————————————————————————|
Systeem Parameter
+————————————————————————————————————————————————————————————————————————+
| Start | | |
| Address | Data | Contents and Remarks |
|==========+=========+===================================================|
| 00 00 | 00 - 01 | Master Clock(*1) INTERNAL, DIGITAL |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 01 | 00 - 03 | Sampling Frequency(*1) 44.1K,48K,88.2K,96KHz |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 02 | 00 - 01 | Audio Source(*1) MIC, DIGITAL |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 03 | 00 | (Reserved) |
| : : |
| 00 0F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 10 | 00 - 01 | USB Driver(*1) VENDER, GENELIC |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 11 | 00 - 1F | MIDI Device ID(*1) 1,,,32 |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 12 | 00 - 01 | MIDI Level Meter Tx. Switch OFF,ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 13 | 00 | (Reserved) |
| : : |
| 00 1F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 20 | 00 - 0F | LCD Contrast 1,,,16 |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 21 | 00 - 02 | Peak Level Select -6,-3,0dB |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 22 | 00 - 02 | Effects Routing NORM,P IN,P OUT |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 23 | 00 | (Reserved) |
| : : |
| 00 7F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
(*1)Read Only Parameters.
Ingang Parameters
+————————————————————————————————————————————————————————————————————————+
| Start | | |
| Address | Data | Contents and Remarks |
|==========+=========+===================================================|
| 01 00 | 00 — 01 | Phantom Power 1 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 01 | 16 — 46 | ATT 1 (0dB:40H) —42 — +6dB |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 02 | 00 — 01 | Phase 1 NORMAL, INVERT |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 03 | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 04 | 00 — 51 | LO—Cut 1 TURU,20 — 2.00kHz |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 05 | 00 | (Reserved) |
| : : |
| 01 0F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 10 | 00 — 01 | Phantom Power 2 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 11 | 16 — 46 | ATT 2 (0dB:40H) —42 — +6dB |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 12 | 00 — 01 | Phase 2 NORMAL, INVERT |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 13 | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 14 | 00 — 51 | LO—Cut 2 TURU,20 — 2.00kHz |
|——————————+—————————+———————————————————————————————————————————————————|
| 01 15 | 00 | (Reserved) |
| : : |
| 01 7F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
Effect Parameters
Basic Address
+————————————————————————————————————————————————————————————————————————+
| Start | | |
| Address | Data | Contents and Remarks |
|==========+=========+===================================================|
| 02 00 | 20 — 7F | Effects Patch Name — 1 (ASCII)|
| : | : | : |
| 02 0B | 20 — 7F | Effects Patch Name —12 |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 0C | 10 — 11 | Effects Algorithm Number |
| | | 10H: MIC MODEL + 4 BAND EQ + DYNAMICS |
| | | 11H: MIC MODEL + DYNAMICS + PLUG IN(Preamp) |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 0D | 00 | (Reserved) |
| : : |
| 02 0F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 10 | 00 — 7F | Effects Parameters |
| : | : | |
| 03 7F | 00 — 7F | |
+————————————————————————————————————————————————————————————————————————+
Algorithm 0 (MIC MODELING + 4 BAND EQ + DYNAMICS)
+————————————————————————————————————————————————————————————————————————+
| Start | | |
| Address | Data | Contents and Remarks |
|==========+=========+===================================================|
| 02 10 | 00 — 01 | LINK OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 11 | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 12 | 00 — 01 | Bypass MODEL 1 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 13 | 00 — 01 | Bypass MODEL 2 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 14 | 00 — 01 | Bypass EQ 1 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 15 | 00 — 01 | Bypass EQ 2 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 16 | 00 — 01 | Bypass DYN 1 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 17 | 00 — 01 | Bypass DYN 2 OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 18 | 00 | (Reserved) |
| : : |
| 02 1F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 20 | 00 — 01 | MODEL 1: SW OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 21 | 00 — 05 | MODEL 1: Input 0,,,5 = |
| | | DR—20,SmlDy,HedDy,MinCn,Flat,AKGC3K |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 22 | 00 — 06 | MODEL 1: Output 0,,,6 = |
| | | SML.DY,VOC.DY,LRG.DY,SML.CN,LRG.CN,VNT.CN,FLAT |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 23 | 34 — 4C | MODEL 1: Proximity Effect (0:40H) —12,,,+12 |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 24 | 00 — 6B | MODEL 1: Timelag 0,,,107 = 0,,,3000cm |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 25 | 00 — 01 | MODEL 2: SW OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 26 | 00 — 05 | MODEL 2: Input 0,,,5 = |
| | | DR—20,SmlDy,HedDy,MinCn,Flat,AKGC3K |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 27 | 00 — 06 | MODEL 2: Output 0,,,6 = |
| | | SML.DY,VOC.DY,LRG.DY,SML.CN,LRG.CN,VNT.CN,FLAT |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 28 | 34 — 4C | MODEL 2: Proximity Effect (0:40H) —12,,,+12 |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 29 | 00 — 6B | MODEL 2: Timelag 0,,,107 = 0,,,3000cm |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 2A | 00 | (Reserved) |
| : : |
| 02 2F | 00 | (Reserved) |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 30 | 00 — 01 | EQ 1: SW OFF, ON |
|——————————+—————————+———————————————————————————————————————————————————|
| 02 31 | 16 — 46 | EQ 1: ATT (0dB:40H) —42 — +6dB |
47

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Roland MMP-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info