1. The monitor has two memory zones (1 and 2). Each zone can store
up to 60 measurements.
2. To read memory values from a selected memory zone, use the User-
Switching key to select a memory zone (1 or 2) from which you want
to recall values. Press the Memory key. The first reading displayed is the
average of the last 3 measurements stored in memory.
3. Continue to press the Memory key to view the last previously stored
measurement. Every measurement comes with an assigned memory
sequence number.
Note: The memory bank can store up to 60 readings per memory zone.
When the number of readings exceeds 60, the oldest data will be
replaced with the new record.
16. Recalling Values from Memory
17. Clearing Values from Memory
18. Time Adjustment
19. Data Transfer to PC (Optional)
1. Press the User-Switching key to select memory zone 1 or memory
zone 2.
2. Continue to press and hold the Memory key for approximately 5 sec-
onds, then the data in the pre-designated memory zone can be erased
automatically.
1. To adjust the date/ time in the monitor, press the key. The display
will show a blinking number showing the hour.
2. Change the hour by pressing the key. Each press will increase the
number by one in a cycling manner. Press the key again to confirm
the entry, and the screen will show a blinking number representing
the minute.
3. Change the minute, and date as described in Step 2 above, using the
key to change and the key to confirm the entries.
4. “0” will reappear as the Blood Pressure Monitor is ready for measure-
ment again.
Rossmax provides a free, integrated and user-friendly blood pressure
management software which can be downloaded and installed on your
computer. You may purchase a special designed USB cable in order to
connect Rossmax’s blood pressure monitor and your PC. Please visit the
website at http://www.rossmax.com for proceeding the downloading and
installation process.
20. Troubleshooting
1. The unit contains high-precision assemblies. Therefore, avoid extreme
temperatures, humidity, and direct sunlight. Avoid dropping or strongly
shocking the main unit, and protect it from dust.
2. Clean the blood pressure monitor body and the cuff carefully with a
slightly damp, soft cloth. Do not press. Do not wash the cuff or use
chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as
cleaner.
3. Leaky batteries can damage the unit. Remove the batteries when the unit
is not used for a long time.
4. The unit should not be operated by children so to avoid hazardous
situations.
5. If the unit is stored near freezing, allow it to acclimate at room
temperature before use.
6. This unit is not field serviceable. You should not use any tool to open the
device nor should you attempt to adjust anything inside the device. If you
have any problems, please contact the store or the doctor from whom
you purchased this unit or please contact Rossmax International Ltd.
7. As a common issue for all blood pressure monitors using the oscillometric
measurement function, the device may have difficulty in determining
the proper blood pressure for users diagnosed with common arrhythmia
(atrial or ventricular premature beats or atrial fibrillation), diabetes, poor
circulation of blood, kidney problems, or for users suffered from stroke,
or for unconscious users.
8. To stop operation at any time, press the ON/OFF/START key, and the air in
the cuff will be rapidly exhausted.
9. Once the inflation reaches 300 mmHg, the unit will start deflating rapidly
for safety reasons.
10. Please note that this is a home healthcare product only and it is not
intended to serve as a substitute for the advice of a physician or medical
professional.
11. Do not use this device for diagnosis or treatment of any health problem
or disease. Measurement results are for reference only. Consult a
healthcare professional for interpretation of pressure measurements.
Contact your physician if you have or suspect any medical problem. Do
not change your medications without the advice of your physician or
healthcare professional.
12. Electromagnetic interference: The device contains sensitive electronic
components. Avoid strong electrical or electromagnetic fields in the
direct vicinity of the device (e.g. mobile telephones, microwave ovens).
These may lead to temporary impairment of measurement accuracy.
13. Dispose of device, batteries, components and accessories according to
local regulations.
14. This monitor may not meet its performance specification if stored or used
outside temperature and humidity ranges specified in Specifications.
21. Cautionary Notes
22. Specications
IN0MW821f000000XX
OBM_IB_MW821f_IP_EN_ver1403
www.rossmax.com
Measurement Method Oscillometric
Measurement Range Pressure: 40-250 mmHg;Pulse: 40~199 beats/
minute
Pressure Sensor Semi conductor
Accuracy Pressure: ± 3mmHg; Pulse: ± 5% of reading
Inflation Pump Driven
Deflation Automatic Air Release Valve
Memory capacity 60 memories fro each zone x 2 zones
Auto-shut-off 1 minute after last key operation
Operation Environment 10°C~40°C (50°F~104°F); 40%~85% RH ;
700~1060hPa
Storage Environment -10°C~60°C (14°F~140°F); 10%~90% RH ;
700~1060hPa
DC Power Source DC 6V four R06 (AA) Batteries
AC Power Source DC 6V, >600mA (Plug size: outer(-) is Ø4.0,
inner(+) is Ø1.7)
Dimensions 160 (L) X 120 (W) X 81 (H) mm
Weight 577g (G.W.) (w/o Batteries)
Arm circumference Adult: 24~36 cm (9.4”~14.2”)
Limited Users Adult users
: Type BF :Device and cuff are designed to pro-
vide special protection against electrical shocks.
IP Classification
IP21, Protection against harmful ingress of water and
particulate matter
*Specifications are subject to change without notice.
23. EMC guidance and manufacturer’s declaration
Guidance and manufacturer’s declaration-electromagnetic emissions
The MW821f is intended for use in the electromagnetic environment specied below.
The customer or the user of the MW821f should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment-guidance
RF emissions CISPR 11 Group 1 The MW821f uses RF energy only for its internal function. Therefore,
its RF emissions are very low and are not likely to cause any interfer-
ence in nearby electronic equipment.
RF emissions CISPR 11 Class B The MW821f is suitable for use in all establishments, including
domestic establishments and those directly connected to the public
low-voltage power supply network that supplies buildings used for
domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class A
Voltage uctuations/
icker emissions IEC
61000-3-3
Compliance
Guidance and manufacturer’s declaration-electromagnetic immunity
The MW821f is intended for use in the electromagnetic environment specied below.
The customer or the user of the MW821f should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
± 6 kV contact
± 8 kV air
± 6 kV contact
± 8 kV air
Floors should be wood, concrete or ceramic tile.
If oors are covered with synthetic material, the
relative humidity should be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
± 2kV for power sup-
ply lines
± 1kV for input /
output lines
± 2kV for power
supply lines
Not applicable
Mains power quality should be that of a typical
commercial or hospital environment.
Surge IEC 61000-
4-5
± 1kV line(s) to
line(s)
± 2kV line(s) to earth
± 1kV differential
mode
Not applicable
Mains power quality should be that of a typical
commercial or hospital environment.
Guidance and manufacturer’s declaration-electromagnetic immunity
The MW821f is intended for use in the electromagnetic environment specied below.
The customer or the user of the MW821f should assure that is used in such and environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms
150 KHz to 80 MHz
3 V/m
80MHz to 2,5 GHz
3 Vrms
3 V/m
Portable and mobile RF communications equipment
should be used no closer to any part of the MW821f
including cables, than the recommended separation
distance calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance:
d = 1,2 √P
d = 1,2 √P 80MHz to 800 MHz
d = 2,3 √P 800MHz to 2,5 GHz
Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from xed RF transmitters, as deter-
mined by an electromagnetic site survey, a should
be less than the compliance level in each frequency
range. b
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorp-
tion and reection from structures, objects and people.
a: Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically
with accuracy. To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic
site survey should be considered. If the measured eld strength in the location in which the MW821f is used
exceeds the applicable RF compliance level above, the MW821f should be observed to verify normal operation.
If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocat-
ing the MW821f.
b: Over the frequency range 150 kHz to 80 MHz, eld strengths should be less than 3 V/m.
Recommended separation distance between portable and mobile RF communications equipment and the
MW821f
The MW821f is intended for use in an electromagnetic environment in which radiated RF disturbances are con-
trolled. The customer or the user of the MW821f can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the MW821f
as recommended below, according to the maximum output power of the communications equipment.
Rated maximum
output power of trans-
mitter / W
Separation distance according to frequency of transmitter / m
150 kHz to 80 MHz /
d=1,2√P
80 MHz to 800 MHz /
d=1,2√P
800 MHz to 2,5 GHz /
d=2,3√P
0,01 0,12 0,12 0,23
0,1 0,38 0,38 0,73
11,2 1,2 2,3
10 3,8 3,8 7,3
100 12 12 23
4. Plug in the cuff connecting tube into the unit (Fig. 5).
5. Lay your arm on a table (palm upward) so the cuff is at the same height
as your heart. Make sure the tube is not kinked (Fig. 6).
6. This cuff is suitable for your use if the arrow falls within the solid color line as
shown on the right (Fig. 7). If the arrow falls outside the solid color line, you will
need a cuff with other circumferences. Contact your local dealer for additional
size cuffs.
If any abnormality should arise during use, please check the following
points.
Note: If the unit still does not work, return it to your dealer. Under no
circumstance should you disassemble and repair the unit by yourself.
Symptoms Check Points Correction
No display
when the ON/
OFF/START key is
pressed
Have the batteries run down? Replace them with
four new batteries.
Have the batteries' polarities
been positioned incorrectly?
Re-insert the batteries in
the correct positions.
Voltage Dips,
short interruptions
and voltage vari-
ations on power
supply input lines
IEC 61000-4-11
<5% UT(>95% dip in
UT) for 0,5 cycle
40% UT(60% dip in
UT) for 5 cycles
70% UT(30% dip in
UT) for 25 cycles
<5% UT(>95% dip in
UT) for 5 s
<5% UT(>95% dip
in UT) for 0,5 cycle
40% UT(60% dip in
UT) for 5 cycles
70% UT(30% dip in
UT) for 25 cycles
<5% UT(>95% dip
in UT) for 5 s
Mains power quality should be that of a typical
commercial or hospital environment. If the user of
the MW821f requires continued operation during
power mains interruptions, it is recommended that
the MW821f be powered from an uninterruptible
power supply or a battery.
Power frequency
(50/60 Hz) mag-
netic eld IEC
61000-4-8
3 A/m 3 A/m Power frequency magnetic elds should be at lev-
els characteristics of a typical location in a typical
commercial or hospital environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
EE mark shown
on display or the
blood pressure
value is displayed
excessively low
(high)
Is the cuff placed correctly? Wrap the cuff properly
so that it is positioned
correctly.
Did you talk or move during
measurement
Measure again.
Keep wrist steady
during measurement.
Did you vigorously shake the
cuff during measurement?
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorp-
tion and reection from structures, objects and people.
Here are a few helpful tips to help you obtain more accurate readings:
Blood pressure changes with every heartbeat and is in constant fluctua-
tion throughout the day.
Blood pressure recording can be affected by the position of the user, his
or her physiological condition and other factors. For greatest accuracy,
wait one hour after exercising, bathing, eating, drinking beverages with
alcohol or caffeine, or smoking to measure blood pressure.
Before measurement, it’s suggested that you sit quietly for at least 5
minutes as measurement taken during a relaxed state will have greater
accuracy. You should not be physically tired or exhausted while taking
a measurement.
Do not take measurements if you are under stress or tension.
During measurement, do not talk or move your arm or hand muscles.
Take your blood pressure at normal body temperature. If you are feeling
cold or hot, wait a while before taking a measurement.
If the monitor is stored at very low temperature (near freezing), have it
placed at a warm location for at least one hour before using it.
Wait 5 minutes before taking the next measurement.
1. Press the User-Switching Key to select memory zone 1 or memory
zone 2
2. Press the Speaker ON/OFF key to turn on the speaker, then press the
Language Selection key to switch between languages.
3. Press the ON/OFF/START Key. All digits will light up, checking the dis-
play functions. The checking procedure will be completed in 2 seconds.
4. After all symbols appear, the display will show a blinking “0”. The
monitor is ready to measure and will automatically inflate the cuff
slowly to start measurement.
5. When the measurement is completed, the cuff will exhaust the pres-
sure inside. Systolic pressure, diastolic pressure and pulse will be shown
simultaneously on the LCD screen. The measurement is then automati-
cally stored into the pre-designated memory zone. This monitor will re-
inflate automatically to approximately 220 mmHg if the system detects
that your body needs more pressure to measure your blood pressure.
Note: 1. This monitor automatically switches off approximately 1 minute
after last key operation.
2. To interrupt the measurement, simply press the ON/OFF/START
or Memory key; the cuff will deflate immediately.
3. During the measurement, do not talk or move your arm or
hand muscles.
15. Measurement Procedures
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rossmax MW-821F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info