RB-06 Stereo Power Amplifier
Protection Indicator
3
The RB-06 has both thermal and over-current
protection circuitry that protects the amplifier
against damage in the event of extreme or faulty
operating conditions. The protection circuits
are independent of the audio signal and have
no impact on sonic performance. Instead, the
protection circuits monitor the temperature of
the output devices and shut down the amplifier
if temperatures exceed safe limits.
Most likely, you will never see this protection
circuitry in action. However, should a faulty
condition arise, the amplifier will stop play
-
ing and the LED indicator on the front panel
will light up.
If this happens, turn the amplifier off. Let it
cool down for several minutes, and attempt to
identify and correct the problem that caused
the protection circuitry to engage. When you
turn the amplifier back on, the protection circuit
will automatically reset and the indicator LED
should go out.
In most cases, the protection circuitry activates
because of a fault condition such as shorted
speaker wires, or inadequate ventilation lead
-
ing to an overheating condition. In very rare
cases, highly reactive or extremely low imped
-
ance speaker loads could cause the protection
circuit to engage.
If the protection circuitry triggers repeatedly
and you are unable to isolate and correct the
faulty condition, contact your authorized Rotel
dealer for assistance in troubleshooting.
Specifications
Continuous Power Output 70 watts/ch
(20-20 kHz, < 0.03%, 8 ohms)
Bridged Mono Power Output 180 watts
(20-20 kHz, < 0.1%, 4 ohms) (200 watts at 1kHz)
Total Harmonic Distortion (20Hz-20kHz, 8 ohms) < 0.03%
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03%
Frequency Response ( ±1dB) 10Hz-100kHz
Damping Factor (20-20,000 Hz, 8 ohms) 500
Speaker Impedance (Normal mode) 4 ohms minimum
Signal to Noise Ratio (IHF A network) 116 dB
Input Impedance/Sensitivity 33 k Ohms/1.0 volt
Power Requirements
USA Version 120 Volts, 60 Hz
European Version 230 Volts, 50 Hz
Power Consumption 250 Watts
Dimensions (W x H x D) 437 x 72 x 342 mm
Panel Height 80 mm / 2
5
/32
Weight (net) 7.5 kg, 16.54 lb.
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Troubleshooting
Most difficulties in audio systems are the result of
poor or wrong connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RB-06, refer to the suggestions
for the following conditions:
Front Panel Power Indicator Is
Not Lit
No main power to the RB-06. Check the front
panel power switch. Make sure that it is set to
the on position. Check AC power connections
at the amplifier and the AC outlet.
Fuse Replacement
If everything checks out correctly and you still
cannot get the amplifier to turn on, the internal
power fuse may have blown. If you believe this
has happened, contact your authorized Rotel
dealer for information on where to take your
amplifier to get the fuse replaced.
No Sound
If the amp is getting AC power, but is pro-
ducing no sound, check all of your
connections and control settings on associated
components.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rotel RB06 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info