762662
16
Zoom out
Zoom in
Vorherige Seite
1/73
Nächste Seite
11
* According to model: these systems are specific to certain mo-
dels or are accessories available as an option.
EN
The air we breathe contains particles that can be allergenic: larva
and dust mite faeces, mould, pollen, smoke and animal waste
(hair, skin, saliva, urine), etc.
The finest particles can penetrate deep inside the respiratory
system or can cause inflammation and affect the entire
respiratory system.
(H)EPA ([High] Efficiency Particulate Air Filter) filters retain the
finest particles.
Thanks to the (H)EPA filter, the air released into the room is
cleaner than the air suctioned.
1 • Emptying the dust compartment (5)
After each use, empty the dust compartment as follows:
Take the dust compartment by the handle and remove it (fig.15).
Separate the fine dust compartment (5b) from the main
compartment (5a) (Fig.16).
Empty the main compartment over a dustbin (Fig.17) then
empty the fine dust compartment (5b) (Fig.18).
Clean the compartment seals using a cloth.
Reposition the fine dust compartment on the main
compartment (Fig.19) then put the dust compartment back into
place (fig.20).
2 Cleaning the black foam filter
(18a)
Press the cover release button (fig.21). Tip the cover
backwards (fig.22).
Remove the black foam filter (fig.23) then wash and squeeze
it (fig.24). Leave to dry for at least 12 hours before refitting.
Reposition the black foam filter and close the cover.
3 Cleaning the microfilter (18b)
Press the cover release button (fig.21). Tip the cover
backwards (fig.22).
Remove the filtration cassette (18) then separate the black
foam filter (18a) from the microfilter (18b) (fig.25).
Wash the microfilter (fig.26). Leave to dry for at least 12
hours before refitting.
Reposition the black foam filter and close the cover.
4 Cleaning the HEPA filter (17)
Remove the accessory support* then place the vacuum
cleaner in the vertical position (Fig.27).
Open the HEPA filter hatch (Fig.28).
Remove the HEPA filter from its housing (fig.29). Clean the
HEPA filter by gently patting it over a dustbin (fig. 30).
Reposition it in its housing (Fig.31).
Reposition the hatch until you hear a click indicating that it is
closed (Fig. 32).
5. Cleaning the air/dust separator
system (4)
Remove the hose from the vacuum cleaner.
Open the vacuum cleaner cover (fig. 21-22).
Press the separator release button (fig.33) then remove from
the separation system (fig.34).
Remove the separation compartment (4c) by turning slightly
to the left (fig.35) then separate the two components (fig.36).
Wash the components (4a+b and 4c) in clear water (fig. 37)
and leave to dry for 6 hours.
Refit the filter system components (4):
- Reposition the separation compartment (4c) on the
separation system (4a+b) (fig. 38) by turning slightly until you
hear the click indicating that it is closed (fig. 39).
- Then reposition the entire separation system (4) in the
appliance (fig. 40) and close the cover.
CLEANING AND MAINTENANCE
IMPORTANT: always switch off and unplug your vacuum
cleaner before cleaning or servicing. Check and clean your
vacuum cleaner and the different filters regularly.
IMPORTANT: do not use the vacuum cleaner once the
maximum level (6) is reached on the dust compartment.
IMPORTANT: do not operate your vacuum cleaner
without the filtration system fitted (foam,
microfilter and filter).
IMPORTANT: clean the black foam filter every 6 months or
when the suction is no longer satisfactory.
ATTENTION: let the black foam filter dry completely
and make sure it is completely dry before placing it
back in the appliance.
IMPORTANT: clean the microfilter every 6 months.
ATTENTION: let the microfilter dry completely and
make sure that it is well dry before refitting on the
appliance.
IMPORTANT: if the appliance does not perform as normal
after cleaning the black foam filter and microfilter on your
vacuum cleaner, clean the HEPA filter.
ATTENTION: your appliance is equipped with a
safety system (19) for detecting the filtration
cassette: the cover cannot be closed if the filtration
cassette is not fitted (18a+18b).
IMPORTANT: replace the HEPA filter every 12 months.
The HEPA filter (ref ZR9015.01) is available from your
dealer or in Approved Service Centres.
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rowenta RO8271 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info