49
6.3 Chimney and flue pipes
We guarantee the proper functioning of the appliance if the chimney draught is between 12 and 20 Pa. If the
chimney draught is too high, then a damper must be incorporated.
If there isn’t enough chimney draught, then the following measures can be considered:
• Extending the chimney
• Improving the insulation of the chimney (less cooling of the flue gases)
• Increasing the supply of combustion air into the space in which the appliance is installed.
• Improving the airtightness of the chimney
Many problems with inset fires are caused by badly working chimneys. Therefore some suggestions:
• A round channel is preferred (minimum friction)
• The diameter of the chimney may not be smaller at any point than that of the appliance
• The mouth of the chimney should be unobstructed
• The chimney should be as close as possible to vertical with as few curves as possible.
• The chimney must not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar or
on the roof!
• The chimney may not have too many connections - that reduces the upwards pressure. Consult your
chimney specialist!
• Flue connections to different stoves and fireplaces may not be located opposite each other at the same
height, in order to prevent the chance that combustion gases will not be drawn out. Two flue connections
must be at separated vertically by at least 30 cm.
• For the chimney opening, you will need to comply with your national legislation.
For details on chimneys we refer you to the relevant regulations with which the chimney needs to comply.
6.4 Fitting the frame
The 4-sided finishing frame is secured using 4 screws on the
top and bottom of the convection mantle.
The 3-sided frame finish is also fixed using 4 screws on the top
and bottom right and left corners.
After the frame is screwed into the convection mantle, the fire
door must be opened. The frame is then screwed tight using a
hex key.