735236
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
Digital Thermostats
Model: HTRS230
INSTALLER MANUAL
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
Sales: T: +44 (0) 1226 323961
E: sales@salus-tech.com
Technical: T: +44 (0) 1226 323961
E: tech@salus-tech.com
www.salus-controls.de
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Issue Date: Dec 2015
00191
For PDF Installation guide please go to:
www.salus-manuals.com
Warranty
SALUS Controls warrants that this product (HTRS230) will be free from any
defect in materials or workmanship, and shall perform in accordance with its
specification, for a period of five years from the date of installation. SALUS Controls
sole liability for breach of this warranty will be (at its option) to repair or replace
the defective product.
Customer Name: ....................................................................................................................................................
Customer Address: ...............................................................................................................................................
............................................................................................................................................................................................
....................................................................................... Post Code: ..........................................................................
Tel No: .................................................................... Email: .......................................................................................
Engineers Company: ...........................................................................................................................................
Tel No: ...................................................................... Email: ....................................................................................
Instalation Date: .....................................................................................................................................................
Engineers Name: ...................................................................................................................................................
Engineers Signature: ...........................................................................................................................................
14. Technische Daten
Model: HTRS230
Voltage 230 VAC, +-10 %, 50/60 Hz
Operating performance 230 V: 1,8 W
Temperature setback Adjustable
Temperature range 5°C – 35°C
Span +/-0,5C OR +/-0,25C
Storage temperature -20°C to +60°C
Ambient temperature 0 °C up to 45 °C
Degree of protection IP 30
CE conformity according to Class II ( EN60730 )
Housing material PC, V2
Color RAL 9010 pure white
Connection Screw terminal
Weight 125 g net / 170 g gross
Puls-wide-modulation (PWM) Yes
Profile Modes 3 ( Sun, Moon, Automatic)
Heating and Cooling Yes, automatically Change Over
on the Wiring Centre
Parameter adjustment Yes, in Installer Mode
Dimensions 85mm*85mm*25mm
8. Setting the Thermostat
9. Setting the Thermostat
Note: The d20 will help you to reduce the power outlet on the thermostat.
Setting the hysteresis
You can set the hysteresis by entering the Installer Mode, accessing d01 and after that
selecting the desired value ( PWM / 0.5°C / 1.0°C ). If your device controls the UFH we
recommend to use the PWM algorithm.
Heating and Cooling Selection
Manually
This mode will be indicated by the flashing icons
Press or to change between modes.
Auto
The CO terminal needs to be connected
using the same phase as the power supply.
After that the heating and cooling functions will be done automatically In Installer
Mode, d18 has to be set on 1 (default is 0), when CO wire is connected.
10. Setting the Thermostat
Cooling blocked
When the thermostat is set on Cooling Disabled (d19-->1) it will block the cooling
function for single rooms until the device receives the heating command. During the
periods of Cooling Blocked no special indicator will be displayed on the LCD screen.
Cooling mode indicator will also be turned off.
Protection
When room temperature is over the limit of 36°C, all heating outputs will be turned off
regardless of the control pattern and delay timers. When room temperature is under
the limit of 4°C, all cooling outputs will be turned off regardless of the control pattern
and delay timers.
Device
No
d01
d02
d05
d07
d08
d12
d13
d18
d19
d20
0
0
0
0
1
1
1
2
1
0
5.0-17.0ºC
5.0-35.0ºC
5.0-40.0ºC
2
1
-3,0 ºC to
+3,0 ºC
0
0
0
0
0.0ºC
5.0ºC
35.0ºC
5.0ºC
2
1
PWM
No Connection
Cooling Allowed
1 to 5 actuators loading
Connection
Cooling Disabled
Offset room temp
measuring error (in 0,5 ºC)
Room temp offset
Heating Control
Heating/Cooling Mode
Cooling Blocked
Selecting the number
of actuators
Cooling Control
Valve Protection
Frost Setpoint
Max. Heating Setpoint
Min. Cooling Setpoint
Default
Value
Function
Valves
Denition
On-Off: 0,5 ºC (+_0,25 ºC)
On-Off: 0,5 ºC (+_0,25 ºC)
Disable
Enable
On-Off: 0,5 ºC (+_0,5 ºC)
On-Off: 0,5 ºC (+_0,5 ºC)
11. Factory Reset
12. Heating/Cooling Mode
13. Temperature Offset (TemperatureCalibration)
Press the indicated keys
together for 3 seconds.
Select P47 if you want to
reset to factory settings.
Press to confirm
Press to confirm
Note: In order to
quickly reach 47 you
can hold down
key. The display will
fast forward in steps
of 5.
Heating Mode Cooling Mode
Temperature Mode Heating Cooling
Sunny 20.0ºC 20.0ºC
Moon 17.0ºC 26.0ºC
Frost (heat system)
5ºC --.-
The Temperature Offset can be set at any value between
-3°C and +3°C. Press OK to confirm.
Long press in order to
enter the Settings Mode.
Press or in order to
set the Temperature Offset.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Salus HTRS 230 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Salus HTRS 230

Salus HTRS 230 Bedienungsanleitung - Deutsch - 2 seiten

Salus HTRS 230 Bedienungsanleitung - Holländisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info