735245
1
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
6
8
10
Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.salus-controls.com/uk
RT510+ / RT510TX+ / RT510RF+ is a programmable room thermostat used to control room temperature.
Device launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510+ / RT510TX+ Thermostat RXRT510+ Receiver
1
67
89
4
3
25
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
RT510+ Thermostat RT510TX+ Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs Voltage free
NO / COM / NC terminals -
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Control algorithm ITLC / SPAN ITLC / SPAN
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the
Computime Group.
Maintaining a policy of continuous product
development SALUS Controls plc reserve
the right to change specification, design and
materials of products listed in this brochure
without prior notice.
RT510+, RT510TX+, RT510RF+
RT510TX+ & RT510RF (Thermostat) DIP Switch Settings
RT510+ Wiring diagram
L
RT510TX+
Thermostat
RT510TX+
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510+
Thermostat
RT510+
Thermostat
L
L
NO
N
N
COM
RXRT510+
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX+
Thermostat
RT510TX+
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510+
Thermostat
RT510+
Thermostat
L
L
NO
N
N
COM
RXRT510+
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510TX+ Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
RT510TX+
Thermostat
RT510TX+
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510+
Thermostat
RT510+
Thermostat
L
L
NO
N
N
COM
RXRT510+
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX+
Thermostat
RT510TX+
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510+
Thermostat
RT510+
Thermostat
L
L
NO
N
N
COM
RXRT510+
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510+ Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
Programming - automatic mode
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
6
8
10
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). To do this, rstly choose programming mode: “5-2” (business days + weekend) or “24h” (each
day separately) using parameter d04 from Installer mode. Programmed schedules should use all
time periods.
ON
ON
ELEC SPAN
RAD ITLC
The DIP Switches can be found on the rear of your thermostat.
For all plug-in boiler receiver applications ensure SW1 is set to RAD.
Control feature ITLC SPAN
Operation When ITLC is selected on DIP
switch № 2, the DIP switch №
1 is functional. You can choose
between radiator or electric
heater.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
MON
TUE
WED
THU
FRI
SAT
SUN
MON MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
THU
THU THU
MONMON
MON
MON
MON
www.salus-tech.com
Issue Date: July 2019
V033
For PDF Installation guide please go to
www.salus-manuals.com
Quick Guide
868.0-868.6MHz; <13dBm
Boiler
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
ITLC
RT510+ (Thermostat) Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat.
ON
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Salus RT510TX plus wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info