REMOTE ALARM MODULE
The remote alarm module is connected to the SANICUBIC
®
2
Pro via an HF link. It receives the various types of alarm
information from the unit. If other HF appliances interfere with
the system, a switching system is fitted for the HF code lin-
king the base board with the remote alarm module.
The code can be changed using the switches located on the
2 boards.
In the event of interference with
other HF equipment or other
SANICUBIC
®
2 Pro units installed
nearby, unplug the unit
and the remote module,
flip one of the 4 switches (or several
swithces) on the unit board,
and do the same on the remote unit
board.
WARNING: You should have the same
code on the unit board and on the
remote alarm board.
To install the module on a wall, see illustration:
The alarm module has 5 LEDS and a buzzer.
The LEDs only come on if a fault has been detected.
1/ The red Led “general alarm” LED mirror operation of the
corresponding LED on the base board.
2/ The yellow “HF reception” LED mirrors operation of the
yellow mains power supply LED on the base board:
- On steadily = transmission OK, base board powered by
the mains supply
- Flashing = transmission OK, but mains power supply fault
on the base board (which is thus operating on its battery
power supply)
- Off = no HF reception from the base board = loss of HF
signal, or base board battery flat, or base board failure.
9
ALARM OPERATION
1/ General alarms:
High level alarm:
If the water level in the unit is abnormally high: the buzzer is
triggered and the red LED comes on; the other motor starts
up 3 seconds later (see the illustration showing the control
keyboard).
Temporary alarm:
If one of the 2 motors runs for more than 1 minute: the buzzer is
triggered and the red alarm LED comes on; the other motor starts
up 3 seconds later.
Mains power supply alarm:
In the event of a mains power failure (or if the unit is
unplugged): the buzzer is triggered and the red alarm LED
comes on; the yellow mains power LED also flashes.
2/ Resetting the general alarms:
If the problem that has triggered one of the alarms referred to
above ceases, the buzzer stops, but the red alarm LED stays
on to memorize the fact that the system has met with a
problem.
One of two keys on the keyboard is used to switch the buzzer
off in all cases, but it only switches the red LED off if the pro-
blem that triggered the alarm has been dealt with. The alarm
lights on the remote control box also stay on until the problem
has been dealt with. This avoids the risk of having a system
“abandoned” in fault status.
UNIT ALARM
8h
FIXING THE SANICUBIC UNIT TO THE FLOOR
The SANICUBIC
®
2 Pro unit is equipped with fittings to hold it
on the floor and
prevent it from turning or moving.
1- Place the unit on the desired spot.
2- Locate the 2 holes for attachment to the floor.
3- Place the 2 pins
A
on the floor then replace the appliance.
4- Fix the unit in place with the screws
B
.
8i
ELECTRICAL CONNECTIONS
1- The electrical installation work must be carried out by a
qualified electrician.
The electrical installation must comply with the standards in
force in the country concerned
1-
The power supply must be of the class 1 type. The unit must
be connected via an earthed connection box. The electric
power circuit must be protected by a high-sensitivity 30 mA
differential circuit breaker set at 20 A. The connection must be
used solely to power the SANICUBIC
®
2 Pro. If the power lead
on the unit is damaged, it must be replaced by the manufactu-
rer or its after-sales service to avoid all danger.
red
general
alarm
LED
yellow
transmission
alarm
LED
green
mains
alarm
LED
motor 1
"override"
“General
Alarm”
LED
“Mains”
LED
motor 2
"override"
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur SANICUBIC 2 Pro Expert-line wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info